CL_DFPS_COMP_EWM - Message Class for EWM Compliance Checks
The following messages are stored in message class CL_DFPS_COMP_EWM: Message Class for EWM Compliance Checks.
It is part of development package DFPS_COMPLIANCE_EWM in software component IS-DFS-MM-EXP. This development package consists of objects that can be grouped under "Compliance Check EWM Integration".
It is part of development package DFPS_COMPLIANCE_EWM in software component IS-DFS-MM-EXP. This development package consists of objects that can be grouped under "Compliance Check EWM Integration".
Message Nr ▲ | Message Text |
---|---|
000 | &1 &2 &3 &4 |
001 | Entry in the compliance check storage locations table is missing |
002 | Entry in the hazardous substance tables is missing |
003 | Compliance check rules must be configured for warehouse &1 |
004 | Invalid entry &. Please select a valid entry via the F4 help |
005 | No values found |
006 | **** Start of &1 check for explosive storage loc. &2 **** |
007 | Compatibility group check for explosive storage loc. &1 was successful |
008 | Compatibility group check for explosive storage location &1 failed |
009 | **** End of &1 check for explosive storage loc. &2 **** |
010 | Compatibility group code not maintained for loc. type &1 in Customizing |
011 | Hazard code not maintained for location type &1 in Customizing |
012 | NEW code not maintained for location type &1 in Customizing |
013 | Compatibility group code must be maintained for material &1 |
014 | Hazard division code must be maintained for material &1 |
015 | Compatibility group code must be maintained for material &1 |
016 | BOBF name & is an extension BOBF. Please enter corresponding parent BO |
017 | Explosive storage location not found for Warehouse &1 and Type &2 |
018 | Compatibility group check skipped for destination bin &1 and Type &2 |
019 | Explosive storage loc. not found for storage type &1 and storage bin &2 |
020 | BO class name & already exists. Please enter a new BO class name |
021 | BO node & already exists. Please enter a new BO node name |
022 | Object type selected is an associated object type. No navigation possible |
023 | Object & does not exist in the compliance check master view |
024 | Object & must be an associated object type |
025 | &1 object type cannot be changed to master category |
026 | &1 object type cannot be changed to associated category |
027 | **** Start of &1 check for explosive storage loc. &2 **** |
028 | Net explosive weight check for explosive storage loc &1 was successful |
029 | Net explosive weight check for explosive storage location &1 failed |
030 | **** End of &1 check for explosive storage loc. &2 **** |
031 | Net explosive weight check skipped for destination bin &1 and Type &2 |
032 | Products with compatibility code &1 and &2 are not allowed |
033 | Rule step must be maintained for hazard division &1 and &2 combination |
034 | Net explosive weight value must be maintained for material &1 |
035 | Net explosive weight unit of measure must be maintained for material &1 |
036 | Country must be maintained for explosive storage location &1 |
037 | Hazard division code not maintained for country &1 |
038 | Calculated NEW &1 exceeds the NEW limit &2 for explosive storage loc. &3 |
039 | Total calculated NEW for HD comb &1 and &2 exceeds limit of HD code &3 |
040 | Total calculated net explosive weight is &1. Limit of HD code &2 is &3 |
041 | Calculated net explosive weight for HDcomb &1 exceeds limit of haz div &2 |
042 | Calculated net explosive weight is &1. Limit of HD code &2 is &3 |
043 | Calculated net explosive weight &1 exceeds the limit of HD code &2 |
044 | Quantity in warehouse request is zero. Compliance check skipped |
045 | Associated object type & cannot be deleted |
046 | Assoc. obj type & cannot be assigned. Already assigned to master obj & |
047 | ** Start of compliance check for &1 &2 ** |
048 | ** End of compliance check for &1 &2 ** |
049 | Compliance check was successful for &1 &2 |
050 | Entry is eliminated because the check failed for &1 &2 |
051 | &1 check skipped for destination bin &2 and type &3 |
052 | Protected field &1 in structure &2 cannot be modified for &3 |
053 | Compliance check failed for &1 &2 |
054 | ~~~ Start of &1 check for &2 &3 ~~~ |
055 | ~~~ End of &1 check for &2 &3 ~~~ |
056 | Object has been added to postprocessing |
057 | Explosive storage location &1 is empty. No products found for &2 check. |
058 | Unable to execute the compliance check. See long text for details. |