CNV10994 - Message class for CNV_10994

The following messages are stored in message class CNV10994: Message class for CNV_10994.
It is part of development package CNV_10994 in software component CA-DT-CNV. This development package consists of objects that can be grouped under "Conversion of change documents".
Message Nr
Message Text
000-------------------------------------------------------------------------
001No routine found for object &1 tab. name &2 domain &3
002The data selection was executed for the following objects:
003OBJECTCLAS=&1
004Global parameters for the conversion program are not set
005Parameter & could not be assigned correctly
006 & data records were cleaned up from table CDPOS
007Object is locked by user &1
008Domain &1 not active in dictionary! (OBJECTCLAS=&2,TABNAME=&3)
009&1: Domain length of &2 is not correct
010&1: Total length = &2 exceeds field length = &3
011&1: Overlap of structure fields for &2 and &3
012Change document object table maintained correctly
013&1: Data element &2 not defined in Dictionary
014Data el. &1 not assigned to domain &2! (OBJECTCLAS=&3,TABNAME=&4)
015Following objects for which change documents exist are unknown:
016Overlap of defined offsets! (OBJECTCLAS=&1,PREFIX=&2)
017No unknown or new change document objects were found
018and add the missing conversion-relevant objects in the table
019Carry out 'Maintain and check change document object table'
020Total length = &1 exceeds field length (=90)! (OBJECTCLAS=&2,PREFIX=&3)
021OBJECTCLAS = &1, PREFIX = &2 :
022&1: No entry found in control table
023Data el. &1 not active in Dictionary!(OBJECTCLAS=&2,PREFIX=&3)
024Data el. &1 is not assigned to domain &2! (OBJECTCLAS=&3,PREFIX=&4)
025Suggestion: Offset=&1,Length=&2,Domain=&3,Data el.=&4
026Sample value=&1; &2 % found in value table &3
027Sample value=&1; no value table exists
028Domain &1 not active in Dictionary! (OBJECTCLAS=&2,PREFIX=&3)
029Wrong domain length for &1! correct: &2! (OBJECTCLAS=&3,PREFIX=&4)
030Position 1 for OBJECTID missing! (OBJECTCLAS=&1,PREFIX=&2)
031Position 1 for TABKEY missing! (OBJECTCLAS=&1,TABNAME=&2)
032The spool list contains the same list in a more convenient form
033&1: New prefix?! Value=&2
034OBJECTCLAS=&1,PREFIX=&2 unknown! Structure analysis not possible
035OBJECTCLAS=&1,TABNAME=&2 unknown! Structure analysis not possible
036OBJECTCLAS=&1,PREFIX=&2 unknown! Suggested structure for OBJECTID:
037OBJECTCLAS=&1,TABNAME=&2 unknown! Suggested structure for TABKEY:
038Sample value for OBJECTID: &1
039Sample value for TABKEY : &1
040Check limited to objects with conversion-relevant fields
041Optimization for &1: Program &2 was modified
042WHERE clause added in conversion program &1, lines &2 and &3 ( CDPOS )
043Analysis of newly found change document objects ... (t=&)
044Structure determination is carried out
045Structure determination is carried out with & values for value check
046No structure determination is carried out
047Error: Job name is initial
048Suggested structure: See in change doc. objecttable for OBJECTCLAS = &
049&1: Parameter for intr. field=&2 was not considered
050&1 % of &2 checked data not found! Sample value= &3
051List of FORM routines used:
052'Active' indicator initialized in control table CNV_10994_TSTRUC
053'Active' indicator initialized in control table CNV_10994_TSTRUC
054Wrong log call! Log name is empty
055'Active' indicator set in control table CNV_10994_TSTRUC
056OBJECTCLAS=&1, TABNAME=&2:
057Wrong entry! Data el. &1 is not defined in Dictionary
058Exit maintenance without check
059Sample value=&1;
060&1 &2 &3 &4
061For &1, &2 was added to WHERE clause
062&1,Value=&2: Several prefixes were identified! Conversion with &3
063&1,Value=&2: Error! No date (that makes sense) found in value
064_&1: OBJECTCLAS = &2
065Short description: &1
066Added to CNVSTEPS: &1
067CNVSTEPS entry for &1 &2 &3 exists already => please check
068&1 empty; &2,&3 set to completed in CNVSTATE
069&1 empty! => &2 in CNVTABLES set to Not-use
070Change document object table successfully checked for consistency
071Errors in change document object table
072Job CDOC_FORMS was started! => long text
073Job CDOC_DATA was started! => long text
074CNV_10994_FIND_UNKNOWN_OBJECTS started in background
075There are warnings!
076Special search for change document obj. (&1) with prefix ... (t=&2)
077Parameter number & > 8. Number of parameters is too high!
078Select data from &1 and &2 ... (t=&3)
079Search in other objects with prefix ... (t=&)
080No line is highlighted! Execute 'check' first
081Download of table contents was carried out
082Upload of table contents was carried out
083Check &1 for entries ... (t=&2)
084Download of table contents failed
085BUKRS entry from CNV_10994_TSTRUC (SACH-OBJECTID) was deleted
086BUKRS entry from CNV_10994_TSTRUC (SACH-OBJECTID) was added
087Entry for package &1 and table &2 deleted from CNVSTATE
088More fields in & are relevant for conversion
089No optimization for table &1
090OBJECTCLAS=&1 is unknown! Sample value for OBJECTID: &2
091OBJECTCLAS=&1, TABNAME=&2 is unknown! Sample value for TABKEY: &3
092Value check is carried out with max. & instances
093No value check is carried out
094Read control table ... (t=&)
095Table & not included in CNV_10994_CHECK_OBJECT!! Error!!
096Additional output of known relevant objects in CDPOS and PCDPOS
097Table &1: Table/structure field &2-&3 not defined in DDIC!
098Existing known relevant change document objects:
099Additional output of relevant known objects in CDHDR, PCDHDR, BDCP
100&1 % found, &2 % not found, &3 % initial (&4 checked data)
101&1 % of &2 checked data are initial
102&1,Offs=&2,data el.=&3: No value table exists
103&1,Offs=&2,data el.=&3: Data not found in value table
104No data was loaded! Possible reasons: EXCEL is opened or format error
105OBJECTCLAS=&1,field name=&2,TABNAME=&3,PREFIX=&4 not found in aux. tab.
106_&1: ( OBJECTCLAS = &2 AND TABNAME = &3 )
107_&1: ( CDOBJCL = &2 AND TABNAME = &3 )
108_&1: CDOBJCL = &2
109Special optimization for &1: Lines &3-&4 added/modified in prog. &2
110&1,Offs=&2,data el.=&3:
111TABKEY : OBJECTCLAS=&1,TABNAME=&2,Pos.=&3,Domain=&4:
112Offs=&1,data el. &2: Value=&3; no value table exists
113Offs=&1,data el. &2: Value=&3 not found in value table &4
114Offs=&1,Data el. &2: Value is empty!
115Offs=&1,data el. &2: Value=&3 not in value table &4 => long text
116Offs=&1,data el. &2: added to structure table
117&1 no table/structure! Object may have to be added?! =>long text
118&1: &2 no table! Object may have to be added?! =>long text
119Object may have to be added?! =>long text
120No conversion-relevant data found in CDHDR and CDPOS => long text
121& exists already
122&1 exists already
123&1: ( OBJECTCLAS = &2 AND TABNAME = &3 AND FNAME = &4 )
124Field overflow for &1 with length &2; value=&3
125Additional search for conv. rel. objects in VALUE_NEW/OLD in (P)CDPOS
126Analyze the unknown change document objects! Add them if necessary
127Optimization for &1 in prog. &2 was reversed.
128Missing information in data record in control table: &
129Package No. &1 : &2
130Program CNV_10994_DATA_CHECK completed
131Program CNV_10994_FORMS_CHECK completed
132Simple optimization for &1: Lines &3-&4 added/modified in prog. &2
133New object: &1 with instance=&2 in &3 (&4)
134No tables selected for analysis!!
135&1: Data type &2 for data el. &3 not taken into account for value check
136Change document analysis in: &
137Output of existing known relevant objects in following tables:
138For &1: SELECT statement not found in program &2!
139No optimization for change documents was selected.
140Table name in TABKEY for ALLOCATION is longer than prefix field (=10): &1
141Table name in TABKEY for ALLOCATION is empty: TABKEY=&1
142&1,Prefix=&2,Offs=&3,Data el=&4 transferred to control table
143_Domain=&1,data element=&2 transferred to control table.
144Table name in TABKEY for LAYER is longer than prefix field (=10): &1
145Set class/prefix &1 missing! Object needs to be added! => Long text
146see suggested structure for related TABKEY (adapt offsets!)
147check under type group GSET!
148&1,&2,&3: Prefix could not be determined!
149No change document objects are known for the relevant domains!
150There are warnings! => See log after leaving maintenance
151&1: Conversion without org.-derivation/-delimitation
152Offs=&1,data el. &2: Not transferred automat. to SLO dev./deliv. syst.
153OBJECTCLAS=&1,OBJECTID=&2: Prefix could not be determined!
154The following change document objects (OBJECTCLAS) are relevant:
155No relevant entries found in &! Exclude & from conversion?
156New object: &1,OBJECTCLAS=&2,TABNAME=&3
157Offs=&1,Data el.=&2
158No automat. suggestion for structure possible! See type group GSET.
159No automat. suggestion for structure possible!
160Unknown change docs are (t=&):
161OBJECTCLAS=&1, TABNAME=&2
162OBJECTCLAS=&1
163No new change document objects found for OBJECTCLAS=&1.
164No new change document objects found in table &1.
165General search for change document objects in &1 ... (t=&2)
166Select (OBJECTCLAS,TABNAME) from &1 ... (t=&2)
167New object: &1,OBJECTCLAS=&2
168New object: &1,OBJECTCLAS=&2,PREFIX=&3
169Instance: &1
170OBJECTCLAS= &1
171OBJECTCLAS=&1
172In table &1: &2,&3,&4 ... missing in control table!!!
173&1:(&2;&3) ... in control table -> no domains relevant for conversion
174OBJECTCLAS=&1,TABNAME=&2
175&1:(&2;&3) ... missing in control table!!!
176Does &1,FNAME=&2 (Dtel=&3) exist? VALUE_OLD, VALUE_NEW relevant ?!
177OBJECTCLAS=&1, TABNAME=&2, FNAME=&3 : Data el.=&4
178VALUE_NEW=&1, VALUE_OLD=&2
179Following object classes that are known to be relevant exist:
180Following objects that are known to be relevant exist:
181Following additional objects exist:
182Following objects have relevant VALUE_OLD, VALUE_NEW:
183Prefix could not be identified!! &1,&2
184&1: Org.unit determination: Org. unit empty! Value=&2
185 Org.unit could not be determined (&1)
186Derivation according to org.unit not possible! (&1,&2),TABKEY=&3
187&1: Error in CNV_10000_CHECKOBJECTS! Value=&2
188Error in CNV_10000_CHECKOBJECTS! (&1,&2),TABKEY=&3
189No org. derivation was determined for OBJECTCLAS=&1,PREFIX=&2
190No org. derivation was determined for OBJECTCLAS=&1,TABNAME=&2 &3
191OBJECTCLAS=&1,TABNAME=&2: TABNAME is no table/structure!
192PCDHDR has no relevant object classes => Table &1 set to notuse
193Derivation field is empty! &1,OBJECTID=&2
194Derivation field is empty! &1,&2,TABKEY=&3
195Suggestion was transferred to structure table
196Field OBJECTID: No suitable form routines were found for OBJECTCLAS=&1!
197Field TABKEY: No suitable form r. found for OBJECTCLAS=&1,TABNAME=&2!
198SUBMIT job: & SUBMIT not possible
199The jobs & were scheduled
200&1: Offs=&2, Domain=&3, Data el.=&4
201TABKEY : OBJECTCLAS=&1, TABNAME=&2, domain=&3, data el.=&4
202Select an entry
203USING &1
204CHANGING &1 CHANGED_FLAG.
205&1,Data el.=&2: No form routine found
206OBJECTCLAS=&1,prefix=&2,Domain=&3,data el.=&4:No form routine found
207Sample call: PERFORM &1
208&1
209Select only one entry
210&1,&2,&3: Data in intransparent field initial or not found
211Domain & is not defined or has length zero
212The jobs & were released
213Upload is not allowed in system &1
214Activity terminated
215Job & was started
216No limited selection is possible for &1; range (&2 obj.) is too large!
217No optim. possible for &. Other table fields are converted as well!
218OBJECTCLAS=&1 stored in &2
219There are no relevant object classes
220Table &1 for package no. &2 was initialized
221Existing entries in &1 for package no. &2 were not deleted
222New entry in table &1 for package number &2: &3 &4
223&2 entries for package number &3 were entered in table &1
224For PACKID=&1,OBJECTCLAS=&2 in table &3 EXCLUDE=X set
225Analysis of change documents in phase P has not been finished
226No tables selected for a restricted selection
227No change document tables found for package &1 in phase C
228No non-relevant object classes identified for exclusion
229CDCLS: with restricted selection
230Error during background scheduling of CNV_10994_FIND_UNKNOWN_OBJECTS
231Program CNV_10994_FIND_UNKNOWN_OBJECTS was scheduled in background
232Include &1 filled
233OBJECTCLAS=& cannot be selected for this option
234No change documents for OBJECTCLAS=& found
235Change documents for OBJECTCLAS=& found
236No structure analysis possible
237For OBJECTCLAS=LAYER the structure of OBJECTID=& cannot be determined
238&1: READONLY set
239Object clas EQUI excluded from conversion
240&1: Full Table Scan
241&1: Loop over TCDOB-OBJECT
242Analysis for OBJECTCLAS between &1 and &2
243Analysis of table &1 limited to OBJECTCLAS=&2
244&1: Loop over TCDOB
245Analysis for OBJECTCLAS <= &1
246Analysis for OBJECTCLAS >= &1
247'Find unknown change document objects' was not yet completed
248Active phase is not 'Package Settings'
249New entry added INTRANSPARENT FIELD=&1, OBJECTCLAS=&2, TABNAME =&3.
250Minimum package size must be lower or equal to parallel threshold
253Transport order was created
254Entry changed: INTRANSP FIELD =&1, OBJECTCLAS =&2, TABNAME =&3
255Entry deleted:INTRANSP FIELD =&1,OBJECTCLAS =&2,TABNAME =&3
256Value &1 was found in value table &2 for domain &3
257Value &1 was not found in value table &2 for domain &3
258Entry copied : INTRANSP FIELD =&1, OBJECTCLAS =&2, TABNAME =&3
260Mode 'Parallel selection' executed
261Mode 'Single program' executed
262No relevant object classes found; &1 excluded from conversion
263&1: In program with ID=&3: OBJECTCLAS=&2
264Selection of &1 with single program
265Settings are kept
270No suitable rule found (Struct. &1, domain &2, data element &3)
288No new change document objects found
290&1=&2 unknown! Sample value for OBJECTID: &3
353No change documents for OBJECTCLAS=& found
354Change documents for OBJECTCLAS=& found
357All valid TABNAME for & are already included in structure table
400Active package not found
503Month & is not plausible
504Day & in month & is not plausible
506Day & is not plausible
511Date & contains invalid characters
790CNV_10994_START_SEARCH called with IMMED=&1,START=&2,DATE=3,TIME=&4
791CNV_10994_START_ANALYSE was called with IMMED=&1,START=&2,DATE=3,TIME=&4
792CNV_10994_START_SEARCH called with IMMEDIATE action
806Select at least one entry
807Choose only one entry
808Select no more than & entries
890Table & is not defined in the system
891Table PCDHDR is empty. No PCDPOS analysis is started
892PCDHDR is set to NOTUSE. PCDPOS is not selected
893Job &1 was scheduled and released
894Job &1 was scheduled, but not released
895Job &1 was scheduled with start date (&2 &3)
896Check for activity Find Unknown Change Document Objects is successful
897Check for activity Find Unknown Change Document Objects is failed
898Please check the logs of activity Find Unknown Change Document Objects
899Change documents object classes excluded from conversion are:
Privacy Policy