CRM_IU_PROD - Utilities Product-Related Messages

The following messages are stored in message class CRM_IU_PROD: Utilities Product-Related Messages.
It is part of development package CRM_IU_PROD in software component CRM-IU-S. This development package consists of objects that can be grouped under "Utilities: Products".
Message Nr
Message Text
001Utilities attributes must be migrated before editing
002Select an attribute
003Target attribute &1 is marked for "Trigger BRFplus Evaluation"
004Attribute &1 is used as target in condition: Cannot start BRFplus eval.
005Target attribute &1 does not exist in product &2
006Target product &1 not defined as a component in the package
007To create a 'CASE' expression, select one attribute only
008You cannot use expession type &1 for application usage &2
009You cannot use copy functions for this application usage
010Function ID &1 does not exist
011Function &1 is used in product &2; deletion is not allowed
012Enter a value for the "Product Determination Group" attribute
013Only one product determination group can be assigned
014You cannot assign structure &1 to the function context
015You cannot change elements in namespace 'IU*' reserved for generated data
016Attribute &1 used in product &2 is not defined in Customizing
017BRFplus rules for product &1 contain a cyclic condition; prod. is invalid
018Value of attribute &1 was changed from &2 to &3
019Attribute values were changed automatically; check selected attributes
020Only released versions exist; create a new one first
021Version &1: "Valid From" needs to be later than in last version
022Version &1: "Valid From" needs to be earlier than in follow-up version
023Master data template is not released; status change failed
024Master data template &1 is not valid
025Master data template &1 is not released
026Value of attribute &1 was changed from &2 to &3
027To create a copy function, select exactly one attribute to copy from
028Product &1 has not been released; release first
029Product &1 can be sold with last released version &2
030Make entries in all mandatory fields
031More than one active BRFplus function assigned to &1 &2 for usage &3
032BRFplus function &1 is assigned to &2 &3 more than once
033Reference product &1 must not be sold directly
034Product module &1 must not be sold directly
035Product &1 contains non-unique attribute(s) &2
036Product determination group &1 must not contain blanks
037Product determination group &1 is longer than 16 characters
038Select a valid price source
039Master data template &1 does not exist
040Product &1 only exists with the status obsolete
041No valid version available for product &1
042Product &1 can be sold in status &2 for version &3
043Save or discard your changes before navigating to a historic version
045All assigned products use current version; &1
046No changes were made for product &1
048Master data template exists for product and reference product
080*--- Product Package: Value Definition ---*
081Low is initial; check value definitions
082Ranges should not overlap; check value definitions
083Fixed value in range; check value definitions
084Lower limit must be lower than upper limit
086** Product Package: Attribute Definition **
087Attribute &1 is no longer defined in Customizing; check ATTR definitions
088Default value &1 not defined for attribute &2; check ATTR definitions
089Default value &1 not allowed because value definition is not active
090BRFplus function &1 does not exist in application &2. Create function?
091Name conflict between IPC and simplified configuration attributes
092*--- Product Package: Package Definition ---*
093Package must contain at least one component
094BRFplus function &1 does not exist
095&1 at product &2/attribute &3
096&1 at product &2 for target attibute &3
097&1 at product &2
098*--- Product Package: Product Validity ---*
099Ranges should not overlap; check product validity
100From date should be earlier than to date; check product validity
101The fields valid from and valid to must be filled; check product validity
102Rule ID &1 does not exist
103BRFplus function &1 does not exist. Create function?
104Execution of BRFplus function &1 for attribute &2 failed
105Attribute &1 of BRFplus function &2: Type &3 is incompatible with type &4
110*--- Product Package: Conditions for attributes and package component --*
111BRF function must not be initial
112Target attribute must not be initial in conditions for attributes
113If type of value determination = B (keep value), value must be initial
114Attribute type for value determination must not be initial
115Maintain simple/complex rules in utilities attributes
116New product in condition must not be a package
117New target product must not be initial
118Product &1 is already assigned as a package component
119Select one condition
120Package &1 must not contain additional packages as components
121Action not possible; no attributes are defined
122Cannot add product &1 to package twice
123Target attribute &1 does not exist in target product &2
124Target attribute &1 does not exist
125Maintain all required attributes
126BRFplus function with the name &1 already exists
127BRFplus function name contains invalid characters
128BRFplus function &1 cannot be used for &2
129BRFplus function &1 does not exist
130BRFplus function &1 is not admissible for the current usage
131BRFplus function &1 belongs to an inactive BRFplus application
132Attribute &1 exists in the BRFplus context for attribute &2
133Attribute &1 exists in the BRFplus context for target attribute &2
134Attribute &1 exists in conditions, delete attribute in conditions first
135Attribute &1 is a target attribute in conditions: Possible conflict
136Product module &1 contains attributes that already exist in &2
137Package &1 contains redefined objects from component &2.
138The product &1 needs to be migrated. Do you want to continue?
139Product &1 has been updated
140No valid transport request found for user &1
141No valid transport request selected
142Changes to BRFplus object &1 are not allowed
143You are locking BRFplus function &1; switch to display mode first
144BRFplus function &1 is locked by user &2; changes not possible
145Parameter &2 has been added to the context for BRFplus function &1
146Parameter &1 has been added to the decision table as a condition column
147Parameter &1 has been added to the decision table as a result column
148Recursion for new component detected; product usage path: &1&2&3&4
149Product determination objects cannot be assigned to packages
150No attributes assigned to product finder and configurator profile &1
151Attributes have not been customized correctly
152Product finder and configurator profile &1 does not exist
153No BOL tree profile group assigned to profile &1
154No external object name assigned to profile &1
155Object does not match external object name &1
156Do not create a quotation based on competitor product &1
157Do not create a contract based on competitor product &1
158Do not create a quotation based on product determination object &1
159Do not create a contract based on product determination object &1
160Do not create a quotation based on reference product &1
161Do not create a contract based on reference product &1
162Do not create a quotation based on product module &1
163Do not create a contract based on product module &1
164Do not create a contract based on product module &1
165Product determination object (PDO) &1 can only be assigned to another PDO
166Parameter &1 has been removed from context of function &2
167Condition column &1 has been removed from the decision table
168Result column &1 has been removed from the decision table
169Parameter &1 has been removed from the result structure
170Version already transported with the status "Active for Testing"
171Parameter &1 has been added to the result structure
172Assignment not possible due to recursion (&1&2&3&4)
173Parameter &1 is still used in expression &2; removal not allowed
174Reference product &1 contains attributes that already exist in &2
190Simplified configuration attributes successfully uploaded
191Simplified configuration attributes have not been uploaded completely
192File &1 does not exist
193Simplified configuration attributes successfully downloaded
194Downloading simplified configuration attributes failed
200Download cancelled because the locks could not be read
201Download cancelled because the requested object is locked
202Upload cancelled because the locks could not be read
203Upload cancelled because the requested object is locked
204IPC configuration for item &1/product &2 not available
205Multi-level IPC configuration for &1 not supported
206Multi-value IPC characteristic &1 of &2 not supported
207Product with product GUID &1 not found (parent product ID &2)
208Atribute &1 is not redefined
209You are not authorized to upload utilities products
210Attribute &1 is incomplete
211Value &2 of attribute &1 is not valid
212Attribute &1 is mandatory
213Allowed value range for attribute &1 is &2
214Blank(s) in name(s) of IPC attribute group(s) were replaced with &1
215Product &1 is not a reference product
216Value &2 of attribute &1 was defined by the IPC configuration engine
217Multi-value IPC characteristics are not supported
218IPC models with characteristic names > 30 char. for &1 are not supported
219Copying of IPC models is not supported
220Reference products are not supported as components
221Product modules are not supported as components
227You are not authorized to upload utilities packages
228You are not authorized to upload utilities reference products
229You are not authorized to upload utilities PDOs
230You are not authorized to upload utilities product modules
231Quotation management contains at least one unsaved quotation
232Contract management contains at least one unsaved contract
240No RFC destination maintained for product version status &1
243Conversion overflow in BRFplus function &1 associated with attribute &2
244Conversion error in BRFplus function &1 associated with attribute &2
254No application logs found
255One application log found
256&1 application logs found
270No Active POD Set
271No PODs in Active POD Set
Privacy Policy