CRM_SSC - Bildfolgesteuerung CRM-Vorgang

The following messages are stored in message class CRM_SSC: Bildfolgesteuerung CRM-Vorgang.
It is part of development package CRM_SSC in software component CRM-BTX-BF. This development package consists of objects that can be grouped under "Screen Sequence Control for CRM Transactions".
Message Nr
Message Text
000***Messages for CRM screen sequence control****************************
001Inconsistency of internal tbls for screen sequence control - termination
002Screen profile type &1 is not available
003Termination of search help for screenSequenceControl due to inconsistency
004No data could be determined for sub-panel &1 - termination
005No business object type is assigned to transaction type &1 - termination
006Unequal assignment to the business object type
007Function modules from development package 'CRM_SSC' must not be used
008No program name is assigned to the screen profile type &1
009Subscreen &1 is not available for program &2
010Function code &1 is not available for program &2
011Unequal assignment to the business object type
012No function codes can be determined for program &1
013Parameters can only be set if screen panel is entered
014Screen panel not necessary for this type of access
015Parameters can only be set if the tabstrip panel is entered
016Tabstrip panel &1 is not assigned to the screen profile type &2
017Parameters can only be set if follow-up panel is entered
018Screen profile &1 is not assigned to the screen profile type &2
019Function module &1 does not conform to the interface
020Subsequent panel cannot be identical to the screen panel
021Tabstrip control data for screen &1 could not be determined - termination
022Trans. type &1 is not defined consistently in Customizing
023Object name &1 is not permitted
024Screen profile &1 is in use and therefore cannot be deleted
025Screen panel &1 is not assigned to the screen profile type &2
026No screen panel could be determined for start function code &1
027No subscreen data could be determined for screen panel &1
028Incorrect or incomplete parameter transfer for call up &1
029Inconsistency in the Customizing tables for CRM screen sequence control
030No subscreens could be determined for program &1
031Screen profile type &1 is in use and cannot be deleted
032No screen profile type can be determined
033Item profile category &1 is in use and cannot be deleted
034No screen profile could be determined
035Subscreen &2 is used more than once in screen panel &1 - termination
036Item profile &1 is in use and cannot be deleted
037Screen profile &1 is not defined in Customizing
038Item category &1 is not defined consistently in Customizing
039Item profile &1 is not defined in Customizing
040Enter a function module
041Only enter subscreen if the tabstrip assignment should be changed
042Enter a tabstrip panel
043Enter a screen panel
044Enter a panel (screen panel or subsequent panel)
045Enter the description of the screen profile type
046Enter an item profile category
047Enter description of the item profile category
048Enter an item category
049Enter a business transaction type
050Enter a screen profile type
051Enter a screen profile
052Enter an item profile
053Enter a subscreen number
054Enter description of the screen profile
055Enter a function code
056Enter a tabstrip number (>0)
057Enter number for a subscreen area (>0)
058Enter description of item profile
059Enter program name for function group
060Enter the transaction object type
061Enter the UI method
062Enter the item object type
063&1 entries were removed from the screen sequence control tables
064The assignment of transaction type &1 to screen profile &2 was removed
065Copying not possible, since screen control data already exists
066Sub-panel and tabstrip panel cannot be entered together
067Select the type of table access
068Parameters can only be used if tabstrip assignment is changed
069Transaction type &1 is not assigned to the screen profile type &2
070No transaction types are assigned to screen profile type &1
071Parameters for object to be created must differ from template
072Scrn control data already exists for scrn prof.type &1 and trans.type &2
073Masking indicator '<*>' only allowed for inital tabstrip number
074&1 entries were copied in the tables for screen sequence control
075Item profile category &1 does not exist
076Program &1 cannot be used
077Subscreen not necessary for this type of access
078Program not necessary for this type of access
079All subscreens of function group &1 are used in screen sequence control
080All funct. codes of function group &1 are used in screen sequence control
081Parameter &1 is a reserved value
082Parameter &1 requires the entry of a function module
083Enter a transaction type from the customer name space
084Unequal assignment to the business object type
085No customer-specific trans. types are assigned to screen profile type &1
086Enter the number of a tabstrip between '000' and '700'
087No screen control data is directly assigned to transaction type &1
088Copying not possible, since screen control data already exists
089Name of customer-specific function group must be in customer name space
Privacy Policy