CUX1 - Meldungen f�r Interface Externe Konfiguration <> CBase
The following messages are stored in message class CUX1: Meldungen f�r Interface Externe Konfiguration <> CBase.
It is part of development package CUX_GEN in software component AP-CFG-CBA. This development package consists of objects that can be grouped under "CU: External Communication with Config. (General Part)".
It is part of development package CUX_GEN in software component AP-CFG-CBA. This development package consists of objects that can be grouped under "CU: External Communication with Config. (General Part)".
Message Nr ▲ | Message Text |
---|---|
001 | Unknown Instance &1 |
002 | No instance numbers were copied |
003 | No POSEX was copied |
004 | Classification instance |
005 | The header data for the configurations was not found |
006 | Unknown configuration instance |
007 | Problems occurred during characteristic conversion |
008 | Problems occurred during structure conversion (BOM) |
009 | Unknown error |
010 | Instance &1 comes from classification |
011 | Instance &1 is not a header instance |
012 | Instance &1 has status 'Released' |
013 | Instance &1 has status 'Incomplete' |
014 | Instance &1 has status 'Locked' |
015 | No configuration storage found for instance &1 |
016 | No configuration data copied |
017 | Unknown knowledge base |
018 | An error occurred when copying the header item number |
019 | Conflict when determining subitems |
020 | Configuration has status 'Released' |
021 | Configuration has status 'Incomplete' |
022 | Configuration has status 'Locked' |
023 | An error occurred when determining the characteristic master data |
024 | Master data for all characteristics found |
025 | Missing BOM application |
026 | An error occurred when determining the structure master data |
027 | No profile with name &1 was found |
028 | An error occurred when determining the configuration status |
029 | Missing class type when determining status |
030 | No status found for status conversion |
031 | An error occurred when inserting data in configuration storage |
032 | The data has been successfully added to configuration storage |
033 | No configuration number was copied |
034 | No root instance found in header data |
035 | Instance &1 occurs twice |
036 | Configuration &1 has no instances |
037 | The configuratio of instance &1 does not exist |
038 | The configuration of instance &1 was loaded from the database |
039 | Instance &1 has changed |
040 | The configuration has changed |
041 | No configuration profiles were found |
042 | CUVK: Unknown instance &1 |
043 | CUVAL: Unknown instance &1 |
044 | The alphanumeric instance number &1 is not allowed |
045 | The alphanumeric configuration number &1 is not allowed |
046 | CUPRT: Unknown instance &1 |
047 | CUINS: Unknown instance &1 |
048 | Processing error: Instance GUID |
049 | The instance GUID contains errors |
050 | Version &2 of knowledge base &1 not found |
051 | Knowledge base with internal number &1 was not found |
052 | Start: Convert Knowledge Base in External Format |
053 | End: Convert Knowledge Base in External Format |
054 | Start: Convert Knowledge Base in ERP Format |
055 | End: Convert Knowledge Base in ERP Format |
056 | Requested delivering plant &1 deviates from plant &2 for knowledge base |
057 | SD BOM application &1 deviates from application &2 of knowledge base |
058 | Part-of table does not match the instance table |
059 | Root instance not found |
060 | Characteristic & unknown |
061 | Product/class/object &1 (type &2) not found |
062 | Only configurations without structure explosion allowed (single-level) |
063 | Object &1 in version &2 of knowledge base &3 was not found |
064 | The parent profile has already been set |
065 | Internal error: Profile has already been set |
066 | Error determining BAPI format for configuration profile |
067 | No valid configuration profile found |
068 | The profile deviates from the old profile |
069 | The owner was not copied |
070 | Object &2 (type &1) cannot be configured |
071 | Lower-level instance in configuration scenario SET |
072 | Characteristic &1 for characteristic &2 occurs twice |
073 | Two values for single-valued characteristic &1 |
074 | No valid configuration profile found for &1 &2 |
075 | Unknown item &1 &2 &3 in BOM of &4 |
076 | Value &1 of characteristic &2 cannot be converted into a numeric format |
077 | More than one valid configuration profile was found for &1 &2 |
078 | Standalone SCE knowledge base: No reference to configuration profile |
079 | Instance &1 occurs twice in part-of table |
080 | Start: Instance conversion |
081 | End: Instance conversion |
082 | Start: Conversion of part-of data |
083 | End: Conversion of part-of data |
084 | Start: Conversion of observer data |
085 | End: Conversion of observer data |
086 | Start: Conversion of owner data |
087 | End: Conversion of owner data |
088 | Start: Conversion of characteristic value assignment |
089 | End: Conversion of characteristic value assignments |
090 | Conversion error: &1 |
100 | Internal error: Inconsistent data for method &1 |
101 | Internal error: Error when accessing &1 |
102 | Unknown object type &1 (table &2) |
103 | Invalid part-of type &1 |
200 | No data found for test run |
201 | No observer found for test run |