DAAG_COMMON - Messages for DAAG_COMMON

The following messages are stored in message class DAAG_COMMON: Messages for DAAG_COMMON.
It is part of development package S_DAAG_COMMON in software component BC-CCM-DAG. This development package consists of objects that can be grouped under "Jointly Used Objects".
Message Nr
Message Text
000*** Message ***
001Table &1 does not exist in the active version
002able &1 does not have a &2 field
003Table field &1-&2 is not type &3
004Specify a data aging runtime class
005Runtime class &1 does not exist
006Runtime class &1 is not active
007Runtime class &1 is inconsistent
008Runtime class &1 does not implement interface &2
009Runtime class &1 not permitted
010Runtime class &1 contains a syntax error
011Table &1 does not have a &2 field
012Data aging object &1 is not extensible
013Analysis program &1 does not exist
014By entering &1, data aging object &2 inherits from itself
015Table &1 cannot be used because it permits table buffering
016Table &1 is not assigned to a partioning object
017&1 is not a transparent table
018Table &1 does not belong to data aging object &2
019Table type or structure cannot be generated for table &1
021No super data aging object to activate
029Cannot delete tables; &1 is not a enhancement data aging object
030Data aging object &1 is not an enhancement data aging object
031No tables provided for deletion from enhancement object &1
032Enhancement object &1 does not have any tables
033Invalid tables provided; tables not part of enhancement object &1
034Number &1 is too big; table &2 has only &3 key fields
035Data aging object &1 cannot be used in groups &2 and &3
036BAdI Definition &1 is not implemented for database system &2
037Table &1 does not belong to enhancement &2 of data aging object &3
038Switch &1 does not exist
039BAdI definition &1 does not exist
040The reuse class &1 cannot implement runtime interface &2
041Cannot delete &1; this object is not a enhancement data aging object
042daag_common_message_042
100DAAG_DATA_AGING business function or profile parameter not selected
101&1 cannot be activated as profile parameter &2 is not selected
102Profile parameter abap/data_aging is not set for data aging
103DAAG_DATA_AGING business function is not active
104Database does not support data aging
110Transferred table list is empty
111Error while calling the database statistics function
112Partitioning object &1 does not exist
113No tables assigned to partitioning object &1
114Error while determining partitions
116Data object &1 cannot be created while upgrade is running
118Partition ranges cannot be created while upgrade is running
119Enhancement object &1 cannot be created while upgrade is running
120Enhancement object &1 cannot be deleted while upgrade is running
121Enhancement object &1 cannot be updated while upgrade is running
122Data aging object &1 cannot be deactivated while upgrade is running
123Tables cannot be deleted while upgrade is running
170Enhancement data aging object cannot be assigned to a data aging group
171Service data aging object cannot be assigned to a data aging group
172Reuse data aging object cannot be assigned to a data aging group
173&1 is not an application data aging object
174You cannot add a destruction object to a data aging group
200Data aging object &1 is assigned to data aging group &2
201Do you want to start the data aging run for data aging group &1?
202Other data aging objects also belong to data aging group &1
203Last data aging run for data aging group &1 lasted &2 seconds
300No tables associated with the data aging object
301Partition does not exist for the selected table
302Table not associated with any data aging object
303Specify a destruction runtime class
304Specify a data aging and destruction runtime class
305Group not assigned. Navigate to Data Aging Groups
306Navigate to Data Aging Groups
308Data aging object &1 is already maintained in the group &2
309Undo interface &1 is not implemented for runtime class &2 of aging obj &3
310Data aging run failed due to unavailability of resources
311Enter keys for table &1
312Table &1 is not a column store table
Privacy Policy