DDACT - Meldungen zur Aktivierung von DD-Objekten

The following messages are stored in message class DDACT: Meldungen zur Aktivierung von DD-Objekten.
It is part of development package SDTB in software component BC-DWB-DIC-AC. This development package consists of objects that can be grouped under "ABAP Dictionary: Tables".
Message Nr
Message Text
000*-------------------------------SQLT------------------------------------*
001Activate & &
002& & was activated
003& & was not activated
004Check & &
005& & was checked successfully
006& & was checked and contains errors
007&: The value & for the type of the SQLT table is unknown
008Structure can be changed; adjustments to DB can be made
009You cannot change the structure of or convert &
010&: The value & is not permitted for &
011The field & occurs more than once
012Error changing database
013Could not write runtime object
014Could not write dictionary sources
015Could not change the field &
016The second field must be a key field named VARKEY
017Only character-like types can be used in the key
018The key is longer than the maximum allowed length &
019The number of keys is greater than the maximum allowed number &
020No data fields have been declared
021Field & may not be a key field
022Field & must be last field and of type 'RAW'
023The data is longer than the maximum data length &
024Enter at least one key field apart from PAGENO
025The key is longer than the maximum allowed length &
026The field & must be a key field
027You cannot change function fields (&: Type & with length of &, key field)
028Cannot change function fields (&: type & has length &, not a key field)
029Field &: type DEC, decimal places not possible in logical cluster field
030Table created in the database
031Table deleted from the database
032The table & could not be created in this newest version
033The input parameters are incorrect
034Activate table & (active version)
035Length of VARDATA field cannot be changed
036Only two data fields DATALN and VARDATA are allowed
037Length VARDATA field is set to & in active version
038Table & does not exist
039TIMESTMP field must have length 46, change not possible
040Function field cannot be changed (&: type with length &/&, no key field)
041Structure change not possible since cluster already contains log. tables
042Deletion not possible since cluster contains logical tables
043Cannot change structure; table pool already contains logical tables
044Deletion not possible because table pool already contains logical tables
045Field &: Type INT8 is not supported
046No activations allowed in shadow system
Privacy Policy