EAML -
The following messages are stored in message class EAML: .
It is part of development package EAML in software component PM-EQM. This development package consists of objects that can be grouped under "".
It is part of development package EAML in software component PM-EQM. This development package consists of objects that can be grouped under "".
Message Nr ▲ | Message Text |
---|---|
001 | Mandatory field &1 is not filled |
002 | Enter only numeric values |
003 | Enter unit of marker |
004 | Offset type code &1 does not exist |
005 | Technical object &1 does not exist |
006 | Functional location &1 is not a linear asset |
007 | Equipment &1 is not linear |
008 | Enter a valid value as &1 |
009 | Enter a numeric value as &1 |
010 | Enter a value between &2 and &3 as &1 |
011 | Enter a numeric value as end point |
012 | Enter a numeric value as linear length |
013 | Enter a valid unit of measurement for first offset |
014 | Enter a valid unit of measurement for second offset |
015 | Non-linear technical objects are deleted from selection |
016 | Select at least one technical object to be saved |
017 | Technical object &1 is updated |
018 | Mark at least one column from new values for mass changes |
019 | Mark at least one technical object for applying changes |
020 | No linear technical objects have been selected |
021 | Technical object &1 is not changed |
022 | Enter a numeric value as first offset |
023 | Enter a numeric value as second offset |
024 | Enter a numeric value as distance from start marker |
025 | Enter a numeric value as distance from end marker |
026 | Enter unit of measurement for distance data |
027 | Enter offset type for first offset |
028 | Enter offset type for second offset |
029 | Length does not equal the distance between start point and end point |
030 | Linear data fields are not available for non-linear technical objects |
031 | BAdI for checking linear data detected a problem |
032 | BAdI for checking linear data for a characteristic detected a problem |
033 | Enter different offset types for first and second offset |
034 | Choose only one offset type as the default for first or second offset |
035 | Enter a positive value for linear length |
040 | Class type and object table is not a valid combination |
041 | Class type &1 object table &2 cannot be used for Linear Asset Management |
042 | Linear data for characteristic values was updated |
043 | Table &1, entry &2: Specify a value for field &3 |
050 | Choose a characteristic and characteristic value first |
051 | Errors in linear data for characteristics; saving aborted |
052 | Enter the class type |
053 | Enter the object table |
054 | Only object table EQUI or IFLOT is allowed here |
055 | No linear characteristics are assigned to the technical object |
056 | No linear data for characteristic values could be found |
057 | Linear data cannot be maintained for characteristic value &1 &2 &3 |
058 | Linear data for characteristic values was found |
059 | No linear data for characteristic values was changed |
060 | No input help available |
061 | If segment and start/end/length are filled, only segment is considered |
062 | To select a segment, you must fill both the "from" and the "to" field |
063 | Enter a valid unit of measurement |
064 | You cannot select 'Outside Range': Segment values cannot be excluded |
065 | IntervalBoundaryTypeCode = 3 is allowed for &1 |
066 | Enter a valid TypeCode for Maintenance Request |
067 | Enter a valid MaintenancePlanningPlantID for 'Maintenance Request' |
070 | To display a graphic, select exactly one top-level object |
071 | No object with linear data; graphic cannot be displayed |
072 | Errors in graphics; inform your system administrator |
073 | More than 99 objects; graphic cannot be displayed |
074 | Value &1 of the &2 in object &3 cannot be converted |
075 | Different UoMs; the graphic is displayed in UoM &1 of object &2 |
076 | Graphic cannot be displayed; start points and end points are the same |
080 | The linear measuring point category cannot be changed to non-linear |
098 | Start marker &1 and distance do not match start point &2 &3 (LRP &4) |
099 | End marker &1 and distance do not match end point &2 &3 (LRP &4) |
100 | Enter a valid marker |
101 | LRP &1 already exists |
102 | LRP &1 saved successfully |
103 | LRP &1 does not exist |
104 | Reference LRP &1 does not exist |
105 | Marker &1 has to lie within the reference object (&2 - &3 &4) |
106 | Marker check was executed successfully |
107 | LRP &1 has been deleted |
108 | Marker &1 already exists |
109 | Enter unit of measurement for marker &1 |
110 | Enter only numeric values for marker &1 |
111 | Unit of measurement for marker &1 not valid |
112 | Marker type for marker &1 not valid |
113 | You are not authorized to display LRP &1 |
114 | You are not authorized to change LRP &1 |
115 | You are not authorized to create LRP &1 |
116 | Function is not allowed for technical objects |
117 | Input help only available for marker types E and F |
118 | Input for element &1 too long |
119 | Enter equal unit code for elements StartPoint, EndPoint and Length |
120 | Field &1 is not contained in marker table |
121 | Unit code &1 of linear information elements not equal to backend UoM |
122 | No linear reference pattern (LRP) found |
123 | Enter a technical object for marker &1 |
124 | Column &1 expected at position &2 |
125 | Enter a marker type for marker &1 |
126 | Mandatory field &1 not provided |
127 | You are not allowed to upload markers of LRP &1 to LRP &2 |
128 | LRP &1 is still used in equipment &2 |
129 | LRP &1 is still used in functional location &2 |
130 | Superior object has been changed; linear data of &1 was deleted |
131 | Close dialog boxes in Microsoft Excel before branching to Excel |
132 | Enter a valid start marker for LRP &1 |
133 | Enter a valid end marker for LRP &1 |
134 | Master data of equipment &1 has different LRP &2 |
135 | Master data of functional location &1 has different LRP &2 |
136 | Linear data of marker &1 rounded according to Customizing setting |
137 | Deleted marker &1 is used in equipment &2 |
138 | Deleted marker &1 is used in functional location &2 |
139 | Superior object has been changed; linear data was copied from &1 |
140 | Functional location &1 is inactive |
141 | Functional location &1 is flagged for deletion |
142 | Functional location &1 has a deletion flag |
143 | Equipment &1 is inactive |
144 | Equipment &1 is flagged for deletion |
145 | Equipment &1 has a deletion flag |
146 | Marker ID could not be changed |
147 | Enter the same unit code for elements StartPoint, EndPoint, and Segment |
148 | LRP &1 is not assigned to object &2; marker fields are not copied |
150 | LRP will be changed; there are still documents with LRP &1 |
151 | LRP &1 does not exist; the corresponding marker fields are deleted |
152 | LRP will be removed; there are still documents with LRP &1 |
153 | LRP will be removed; the corresponding marker fields are deleted |
154 | Marker &1 still used and cannot be deleted; see where-used list |
155 | Marker &1 is used in &2 &3 |
156 | Selected markers are not used |
198 | No entry in field &1 allowed if link category is &2 |
199 | Object link ID &1 is specified more than once |
200 | Enter Network ID |
201 | Network ID &1 does not exist |
202 | Network ID &1 already exists |
203 | Enter type of network |
204 | Link category &1 not allowed. Only category &2 is allowed here. |
205 | Enter &1. |
206 | Network &1 saved successfully |
207 | Network type &1 of network &2 not relevant for recording attrib. changes |
208 | For network &1 no attribute values have been created |
209 | Object link &1 is already assigned to network ID &2 |
210 | Status could not be changed for all marked object links |
211 | Field &1 is not part of the field list of network attributes |
212 | Enter record date in row &1 |
213 | Deletion status has been set |
214 | Deletion status has been reset |
215 | You are not authorized to create attribute values for network &1 |
216 | You are not authorized to change attribute values for network &1 |
217 | You are not authorized to display attribute values for network &1 |
218 | No temporary ID for attribute values has been provided in line &1 |
219 | Temporary ID &1 for attribute values has been specified twice |
220 | Network attribute &1 is not allowed for network &2 |
221 | Attribute property &1 is not allowed for network &2 |
222 | Maintain attribute properties for network attribute category &1 in IMG |
223 | Network &1 cannot be deleted because it is a linear network |
224 | No linear data has been maintained in row &1 |
225 | Maintain at least one attribute property in row &1 |
226 | Data checked successfully |
227 | Value &1 is not allowed for property &2 |
228 | Exported network attribute values contain errors |
229 | Use of special characters and/or blanks is not allowed |
230 | You are not allowed to display network data |
231 | You are not allowed to maintain network data |
232 | Internal error during calculation of dynamic segmentation |
233 | Install JNET component of SAPGUI |
234 | No F4 help available since there is no linear reference pattern |
235 | Network type could not be determined; enter type of network |
236 | No network attribute values have been recorded |
237 | Conversion error occurred during calculation of dynamic segmentation |
238 | Network attribute category &1 is not assigned to network &2 |
239 | Specify exactly one attribute category when selecting by attribute values |
240 | Network attribute category &1 does not exist |
241 | Error during creation of selection criteria for attribute values |
242 | Maximum of 36 network attributes to be displayed has been exceeded |
243 | Graphic can only display values less than 100000, change display UOM |
244 | Selection criteria for attribute values have been cleared |
245 | No unit of measurement has been specified |
246 | Unit of measurement has not been changed |
247 | Enter unit of measurement |
248 | Error during XML creation for graphic display |
249 | Specify data element or data type for attribute property &1 |
250 | All properties of network category &1 require a data element / type |
251 | Only the first 1000 markers are displayed |
252 | No value has been specified for attribute property '&1' in row &2 |
253 | Field '&1' in row &2 had wrong format and was cleared |
254 | Attributes for network &1 saved successfully |
255 | Recording attrib. changes requires a network type for network &1 |
256 | No changes were made |
257 | For network &1 no inactive attribute records exist |
258 | No network attribute records match the specified filter values |
259 | Only one default profile allowed |
260 | Navigation is not possible |
261 | No default profile selected |
262 | Use only numbers and decimal separator '.' for allowed numeric values |
263 | Value &1 exceeds the defined length of the property value |
264 | Type &1 of data element &2 is not supported |
265 | Use only numbers for allowed integer values |
266 | Enter value for property &1 in format '&2' |
267 | There are more than &1 markers, markers are not displayed |
290 | Linear data exists for the object link; use transaction IN22 for editing |
301 | Neither IT_NETID nor IT_OBJ_LNK_ID was specified |
302 | Both IT_NETID and IT_OBJ_LNK_ID were specified |
303 | Specify technical object type for network (parameter IV_KANTYP) |
304 | Caution: You are about to change defaulted linear data of the object link |
305 | Object link &1 is not assigned to network &2 |
306 | This LRP type is not assigned to any linear reference patterns |
307 | No LRP Type exists which meets the entered values |
308 | Deletion flag for network is set. Data cannot be changed. |
309 | Deletion flag for network is set. Switch to edit mode is not possible. |
310 | Linear data of object links have been defaulted from technical objects |
311 | Deletion flag for network &1 is set. Network cannot be assigned. |
312 | Linear data of object link &1 &2 defaulted from technical object &3 |
313 | Object is not LAM-relevant |
314 | Enter a unique item number. |
315 | The start and end points of &2 and &1 can be equal. |
666 | This program can only run if Business Function LOG_EAM_LINEAR_2 is active |
897 | No defaulting of the linear data fields for measuring point & |
898 | Internal error during defaulting processing |
899 | No defaulting of the linear data fields for object & tab key & |