EH2 - Additional Messages for Disconenction/Reconnection

The following messages are stored in message class EH2: Additional Messages for Disconenction/Reconnection.
It is part of development package EE00 in software component IS-U. This development package consists of objects that can be grouped under "IS-U: General (Domains and General Objects)".
Message Nr
Message Text
001Cannot have more than one AMI device selected in one disconnection order
002Cannot have more than one AMI device selected in one reconnection order
003Cannot have both AMI and non-AMI devices selected
004Cannot have both AMI and non-AMI devices selected
005Order code and PM Plant cannot be filled for remote disconnections
006Order code and PM Plant cannot be filled for remote reconnections
007Device not selected for remote disconnection
008Device not selected for remote reconnection
009Are you sure you want to immediately trigger a disconnection?
010Are you sure you want to immediately trigger a reconnection?
011Remote disconnection is not enabled for this device
012Remote reconnection is not enabled for this device
013Select at least one device for remote processing (AMI)
014Remote action cancelled
015Changes also affect the work-item; do you want to process it now?
016Cannot remotely disconnect un-approved orders
017Cannot remotely reconnect un-approved orders
018Are you sure you want to immediately cancel the remote disconnection?
019Are you sure you want to immediately cancel the remote reconnection?
020Proposed date must be earlier than &1
021Agreed date cannot be earlier than start date
022Planned date must be set later to meet minimum processing period
023Planned date must be &1 or later
024Only set "Notif. Reqd" flag on devices associated with a business partner
025Notification required but not yet obtained
026Notification workitem could not be created
027Proposed date must be &1 or earlier
028Enter a future date as an agreed date
029Cannot reschedule disconnection order due to service order
030No objects available; installed devices are currently locked
031Successfully sent &1 message.
032Failed to send &1 message.
033Proposed date must be &1 or later
050Cannot open the disconnection document; reason: &1
051Cannot get the disconnection object; Document Number: &1
052Remote action failed; reason: &1
053Save disconnection document failed; reason: &1
054Disconnection document selected: &1 &2 &3
055Disconnection activity must have status &1
057Order sent to MDUS
058Remote action cancelled
059Cannot disconnect approved orders
060Cannot disconnect non-device orders
061Disconnection order &1 not properly retrieved; contact SAP for assistance
062No orders selected
063No disconnection documents found; valid reference object required
064Cannot create order since notification is required for this variant
065No order found for Request ID &1
070Error during Bulk-Processing. &1 objects rolled back.
Privacy Policy