EHPRC_CPM_EXPORT - Export Messages
The following messages are stored in message class EHPRC_CPM_EXPORT: Export Messages.
It is part of development package EHPRC_CP_CORE in software component EHS-MGM-PRC. This development package consists of objects that can be grouped under "Compliance for products".
It is part of development package EHPRC_CP_CORE in software component EHS-MGM-PRC. This development package consists of objects that can be grouped under "Compliance for products".
Message Nr ▲ | Message Text |
---|---|
001 | Report generation variant &1 was read successfully |
002 | Mapping for export type &1 does not exist |
003 | Product data for &1 has to be reported to customer &3 in format &2 |
004 | Product data report in format &2 for &1 has to be created |
005 | Export &1 was processed |
006 | Export &1 complete |
007 | Release report &1 read |
008 | Default parameters determined |
009 | Value file generated |
010 | Cannot read the value for the synchronous generation server |
011 | Cannot read the value for the synchronous generation server |
012 | RFC connection to destination &1 failed (&2 &3) |
013 | Export &1 does not exist |
014 | No WWI application defined for export type &1 |
015 | Error during import of template |
016 | Template imported (&1) |
017 | Decimal separator in the generation variant &1 has to be a dot "." |
018 | Interface category &1 is not defined |
019 | &1 &2: data migration for table &3 in mode &4 started |
020 | ...(specification &1;date &2;report &4; receiver &3) will be processed |
021 | &1 &2: &3 of &4 records changed |
022 | &1 &2: error occurred for &3 of &4 records |
023 | ...(specification &1;date &2;report &4;receiver &3) already exists |
024 | Specification &1: Check &2 is mandatory for outgoing template &3 |
025 | Specification &1: result &2 for check &3 is not allowed (export type &4) |
026 | Specification &1: date &2 of check &3 is later than generation date &4 |
027 | Function &1 configured at export type &2 is inactive or does not exist |
028 | Template is not defined |
029 | Problem while creating the e-mail for export; attempting to continue |
030 | Cannot attach report to the e-mail |
031 | E-mail generation was canceled by the user |
032 | Publish only successfully checked basic materials |
040 | Specification &1 contains basic materials without generated reports |
041 | Specification &1: no released raw report found; current status is "&2" |
042 | Specification &1 contains materials that are currently being uploaded |
043 | Specification &1: locked by IMDS upload of specification &2 |
044 | Specification &1: IMDS node ID could not be determined |
045 | Specification &1: generating final report &2 of &3 for specification &4 |
046 | Specification &1: no reports found |
047 | Generation started on &1 at &2 |
048 | Specification &1 is still generating; wait for it to finish |
050 | Generation variant &1 uses normalization &2 with re rollup |
100 | --------- Messages for IPC related processing ( 100 - 149 ) ------------- |
101 | Company name is missing in supplier section |
102 | Invalid or empty response date in supplier section |
103 | Name of internal contact person is missing in supplier section |
104 | Phone number of internal contact person is missing in supplier section |
105 | E-mail address of internal contact person is missing in supplier section |
106 | Name of authorized person is missing in supplier section |
107 | Phone number of authorized person is missing in supplier section |
108 | E-mail address of authorized person is missing in supplier section |
109 | RoHS compliance data is missing |
110 | Substance declaration/absence declaration is missing |
111 | Manufacturer process information is missing |
112 | IPC declaration type is missing |
113 | Invalid "Max. Cycles at Max Temperature" value &1 |
114 | Export not executed; IPC declaration text is missing |
200 | --- messages for check against check results --- |
201 | No report generated for specification &1; type &2 |
202 | No report generated for specification &1; subcomponent with type &2 |
203 | Check result does not allow creation of raw report for specification &1 |
204 | Check result of component &1 contains a warning/error message |
205 | Messages occurred; check the generation log |
249 | Specification type &1 is assigned to more than one IMDS object type |