EHPRC_CPM_GENERAL - General Messages
The following messages are stored in message class EHPRC_CPM_GENERAL: General Messages.
It is part of development package EHPRC_COMN in software component EHS-MGM-PRC. This development package consists of objects that can be grouped under "PRC common objects for all components".
It is part of development package EHPRC_COMN in software component EHS-MGM-PRC. This development package consists of objects that can be grouped under "PRC common objects for all components".
Message Nr ▲ | Message Text |
---|---|
001 | Parameter &1 not found in environment parameters |
002 | Property/characteristic for parameter &1 not found |
003 | No active IMDS system found in the Customizing activity |
004 | Error in interface of function module &3 (user exit type &1, name &2) |
005 | Error while executing function module &2 in user exit &1 |
006 | Update of the specification data for &1 canceled |
007 | Error while reading specification &1 (&2) |
008 | Cannot set lock for specification &1 |
009 | Error while deleting data from specification &1 (&2) |
010 | Error while creating data for specification &1 (&2) |
011 | Internal error in function &1 (exception &2) |
012 | Specification &1 does not exist |
013 | Generation error on WWI server &1 &2 &3 &4 |
014 | Directory &1 does not exist |
015 | Interface for function &1 module does not follow convention &2 |
016 | Save data first |
017 | Activity canceled |
018 | Invalid value entered &1 &2 &3 &4 |
019 | Last action executed |
020 | Directory path cannot be longer than 80 characters; &1 |
021 | No notation found for language &1 |
022 | No errors during the last action &1 |
023 | Spec.category &1 does not match the material category product or bulk |
024 | Specification type &1 is not assigned to a material category |
025 | No messages occurred |
026 | Max. number of messages exceeded; only 999999 displayed |
027 | Internal error occured; processing aborted |
028 | Function module &1 is not supported as a user exit function |
029 | Error while reading the data for specification &1 |
030 | Maintain a unit for specification &1 in composition of &2 |
031 | At least one of the parameters &1 or &2 has to be maintained |
032 | Unable to determine RECN for SUBID &1; check the substance ID |
033 | Regulatory list &1 does not exist; check your entry |
034 | Path to file too long; downloading to the front end aborted |
035 | Unable to instantiate class &1; operation aborted |
036 | There is no key build function available for normalization &1 |
037 | Unable to execute normalization "IMDS Flat BOM"; no mass is maintained &1 |
038 | Phrase &1 not found |
039 | Response code &1 is not assigned to a priority &2 |
040 | Unable to determine response code &1 &2 &3 |
041 | Exception &1 occurred while creating a GUI container |
042 | Control exception &1 occurred while calling method &2 in class &3 |
043 | Specification &1 has multiple composition instances; first one used |
044 | Exception &1 occurred while reading specification data |
045 | Unable to create or update environment parameter &1 |
046 | Normalization &1 requires the check for the key building function |
047 | Unable to execute IMDS check for specification &1; see SAP Note 1233053 |
048 | Marked lines were not deleted |
049 | Unable to set lock for material &1 (material classification) |
050 | Interface for function module &1 does not follow convention of &2 or &3 |
051 | Data record is locked and cannot be changed |
052 | Inactive instance exists for spec. &1 property &2; instance was not used |
053 | Inactive instance exists for specification &1, property &2 |
054 | Unable to create or assign supplier specification |
055 | Configuration of composition group &1 incomplete |
056 | Use not found in buffer; processing aborted |
057 | Information e-mail not sent due to errors |
060 | Physical path for logical file &1 could not be found |
061 | Directory '&1' is not allowed; enter a file or directory in '&2' |
062 | No active revision exists for regulatory list &1 |
063 | Check &1 is not active for substance &2 |
064 | Internal error &1; no default check result exists for check &2 |
065 | Inconsistency error; listed substance &1 was not found for reg. list &2 |
066 | Internal error &1; missing data for Bill of Materials |
070 | Material Category &1 does not exist or is not active |
071 | Internal error; cannot assign requirement &1 |
100 | Report &1 started |
101 | Report &1 ended |
102 | Instance of composition was split; composition &1 |
103 | Specification &1 not migrated; migrate manually |
104 | Specification &1 recieves data by inheritance, adapt templates |
105 | Invalid unit in characteristic &1 in classification system |
137 | &1 &2 &3 &4 |