FASTEDM -
The following messages are stored in message class FASTEDM: .
It is part of development package FASTEDM in software component IS-U-BI. This development package consists of objects that can be grouped under "EDM for TOU Billing for Residential Customers".
It is part of development package FASTEDM in software component IS-U-BI. This development package consists of objects that can be grouped under "EDM for TOU Billing for Residential Customers".
Message Nr ▲ | Message Text |
---|---|
000 | dummy |
001 | Internal error: Processing has been terminated |
002 | Profile &1 cannot be billed with rate &2 |
003 | Interval &1 of profile &2 is not from interval category 'Minutes' |
004 | Interval &1 does not match interval &2 of profile &3 |
005 | Profile &1 is not a quantity profile |
006 | Formula &1 cannot be instantiated |
007 | Time-of-use formula &1 does not have an implementing class |
008 | Invalid version number for TOU formula &1 |
009 | Error converting UTC time &1 to time zone &2 |
010 | Formula &1 is not derived from class &2 |
011 | Interval ID &1 not supported by profile &2 |
012 | Inconsistent results from formula &1 |
013 | Unit of measurement &1 does not exist |
014 | Enter the ISO code for unit of measurement &1 |
015 | Profile value status &1 not permitted for profile &2 |
016 | No billable profile values in period &1 to &2 for profile &3 |
017 | Error during conversion of date &1 and time &2 |
018 | Time stamp &1 is inconsistent |
019 | Input parameter category &1 not permitted for formula class &2 |
020 | Identification of interval length &1 not permitted |
021 | Time &1 is not a suitable start time for an interval period |
022 | Time &1 is not a suitable end time for an interval period |
023 | Profile values missing for profile &1, time &2 |
024 | Profile value category &1 not supported by profile &2 |
025 | Internal error: Processing has been terminated |
026 | Interval &1 is not from interval category 'Minutes' |
027 | Interval ID &1: Interval length is 0; enter a value |
028 | Interval length cannot be more than 24h (&1 minutes) |
029 | End of validity of status &1 of profile &2 is invalid |
030 | No suitable output parameter for TOU formula &1 |
031 | No suitable input parameter for TOU formula &1 |
032 | TOU formula &1 does not support conversion of unit of meas. &2 to &3 |
033 | Category &2 of input parameter &1 not supported |
034 | Input parameter &2 of TOU formula &1 not filled |
035 | Profile values in period &1 to &2 for profile &3 locked |
036 | Profile values in period &1 to &2 for profile &3 already archived |
037 | Profile &1 is not marked as TOU billable |
038 | Time stamp &1 cannot be rounded to the next interval limit |
039 | Interval for time stamps &1 and &2 is not valid |
040 | Enter the minimum portion in percent |
041 | Unable to read profile type &1 from Customizing |
042 | Unable to read profile category &1 from Customizing |
043 | Profile &1 is not a synthetic profile |
044 | Error during execution of BAdI &1 method &2 |
045 | No additional data available for TOU formulas |
046 | No annual consumption available for profile &1 at &2 |
047 | Invalid annual consumption &1 for synthetic profile &2 |
048 | Synthetic profile &1: Profile values from &2 to &3 are incomplete |
049 | Profile &1: Invalid annual consumption &2 unit of measurement &3 |
050 | Profile &1: Annual consumption is not available |
051 | Missing contract period for simulation period from &1 to &2 |
052 | Profile &1: Incomplete simulation data in table &2 |
053 | Profile &1: Annual consumption has a different unit of measurement &2 |
054 | Profile &1: Profile values from &2 to &3 are incomplete |
055 | Error during consumption determination for synthetic profile &1 |
057 | No factory calendar defined |
058 | Changing profile allocation to installtn.&1 not supported by CPP formula |
059 | Unable to execute CPP formula |
060 | Profile &1: No unique assignment of the profile to a register |
061 | Profile &1: Multiple allocation to installation &2 |