FDT_WD_INFRA - FDT: Message Class for WD Infrastructure

The following messages are stored in message class FDT_WD_INFRA: FDT: Message Class for WD Infrastructure.
It is part of development package SFDT_WD_INFRASTRUCTURE in software component BC-SRV-BR. This development package consists of objects that can be grouped under "BRFplus: Web Dynpro UI: Infrastructure".
Message Nr
Message Text
000Type &1 / subtype &2 is not yet registered or is invalid
001Object &1 is currently locked by user &2; editing not possible
002Object is consistent
003Objects saved and activated
004Object activation failed due to errors
005Some objects are already locked for maintenance
006Objects copied
007Transport entries have been written
008There is no maintenance view available for this object type
009Content object created
010Objects &1 deleted
011Objects not deleted due to errors
012Modification of object is not possible because it was deleted
013Deletion only possible if Object Manager does not visualize an object
014You cannot modify older versions of an object
015Object Manager does not have any open objects
016Maintaining wizard UI is only possible in exclusive mode
017Web Dynpro component does not provide a wizard UI
018The object manager does not display any wizard UI
019You have to save the object before you can activate it
020The object to be created cannot be assigned to the catalog (type)
021Assign a folder or the catalog itself
022Only named objects can be assigned to a catalog
023Object is deleted; editing not possible
024Older versions of an object cannot be changed
025You have to save the object first before you can change the mode
026Objects set to obsolete
027Objects no longer obsolete
028Object is marked for deletion
029Objects not longer marked for deletion
030Object is marked for deletion; editing not possible
031Object is obsolete; editing not possible
032Application is missing
033You have to close the object before you can display another one
034Navigation is not possible in this view
035Object cannot be changed in this system
036No suitable object types for creating available; check filter
037&1 lean trace(s) exist for deployment to be deleted; see long text
039You have to save &1 first
040Application &1 is unknown or has wrong storage type
041You have to enter a name to create a reusable object
042Object name &1: Blanks and hyphens were replaced by underscores
043Inactive version(s) deleted; last active object version(s) are in effect
044Object filter &1 is still assigned in the personalization
045Possible problems with access level; see long text
050Stack is empty
051Object ID &1, timestamp &2 is already in stack
052Object ID &1, timestamp &2 is not in stack
053Maximal stack size is already used
054Object was reloaded since it was changed by another user
055
056Structure assigned to database context must be bound to a CDS view
060Internal error: No Web Dynpro component usage available
061Usage ID &1 is invalid
062You have to save a modified object before you can open another one
063You have to save the object or change to display mode first
070Mode &1 is unknown
080Objects marked for deletion deleted successfully
081Application &1 could not be activated since it is locked by another user
082Application &1 could not be activated
085You have to enter a transport request
088Object &1 cannot be changed because it is deleted
101Display mode &1 is invalid
102Internal HTML control error
103Start of browser failed: Frontend is not supported
104Start of browser failed: Error occurred in SAPGUI
105Start of browser failed: Cannot be executed in background
106Start of browser failed: Error occurred
110No inconsistent objects detected
121Deployment test for service &1 finished successfully
122Managed System &1 deleted succesfully
123Application successfully re-assigned.
124Search did not return any result
150Object &1/Model &2: Changed by node &3 / attr. &4
151Object &1/Model &2: Changed by &3 / &4
152Object was changed by another user, check and save again
201Changes have been saved
Privacy Policy