FRMLMSC - RMS-FRM: Verschiedene Nachrichten Formula
The following messages are stored in message class FRMLMSC: RMS-FRM: Verschiedene Nachrichten Formula.
It is part of development package RMSFRMMSC in software component PLM-RM. This development package consists of objects that can be grouped under "RMS-FRM: RMS Formula - Miscellaneous".
It is part of development package RMSFRMMSC in software component PLM-RM. This development package consists of objects that can be grouped under "RMS-FRM: RMS Formula - Miscellaneous".
Message Nr ▲ | Message Text |
|---|---|
| 000 | Miscellaneous messages for the RMS formula project are created |
| 001 | Package RMSFRM created |
| 002 | All messages called within the project must be defined |
| 003 | here. Additional message classes are: |
| 004 | *) FRMLALL -> General messages |
| 005 | *) FRMLDLG -> Dialog messages |
| 006 | *) FRMLPVS -> Messages for PVS integration |
| 007 | *) FRMLAPI -> API Messages |
| 008 | *) FRMLINF -> Info system messages (search and output functions only) |
| 010 | The messages are divided up into the following areas: |
| 012 | Message no. Usage |
| 013 | 100-299 General messages (called in various components) |
| 014 | 880-899 Test messages (will be deleted before delivery) |
| 015 | 900-999 User-defined messages |
| 100 | General messages (called in different components)------------ |
| 101 | Standard explosion indicator is not set in any formulas for material &1 |
| 102 | Standard explosion indicator is set in several formulas for material &1 |
| 103 | Standard explosion indicator is not set in any formulas for substance &1 |
| 104 | Standard explosion indicator is set in several formulas for substance &1 |
| 105 | System could not determine composition for substance &1 of formula &2 |
| 106 | Proportional values are converted to unit &1 of target input quantity |
| 110 | Units (substance view of formula &1) cannot be converted completely |
| 120 | Error while determining change number data for formula &1 |
| 121 | Clash with preceding change number &2 in formula &1 |
| 122 | Clash with succeeding change number &2 in formula &1 |
| 123 | Change number &1 cannot be used; choose another one |
| 130 | No density has been specified for stream &1 |
| 131 | Environment parameter &1 does not exist in Customizing |
| 132 | Unit of measure &1 is not permitted |
| 133 | Error occurred converting units from &1 to &2 |
| 134 | System cannot determine specification data |
| 135 | Error converting percentage to mass |
| 136 | No density has been specified for specification &1 |
| 137 | Error converting percentage to piece |
| 138 | No conversion factor for piece is specified for specification &1 |
| 139 | Primary output &1: Density in spec. does not equal calculated density |
| 140 | Primary output &1: Total solids of spec. do not equal calcul.total solids |
| 141 | Total solids of primary output &1 do not exist |
| 142 | Density of primary output &1 does not exist |
| 143 | Material &1 is not assigned to a substance |
| 144 | System cannot determine a unique initial formula for the recipe |
| 145 | Standard explosion for output component &1 is no longer unique |
| 146 | Output component &1 no longer has a preferred recipe |
| 147 | Component &1 is indicated as preferred recipe for formulas &2 and &3 |
| 148 | Substance &1, accuracy loss due to reduced number of decimal places |
| 149 | Substance &1, accuracy loss due to reduced number of decimal places |
| 150 | No entries or several entries exist for usage profile &1 |
| 151 | No usage profile exists for value assignment type &1 |
| 152 | No density (aeration) is specified for specification &1 |
| 153 | Lot sizes were reset |
| 160 | Data saved |
| 161 | File &1 does not contain any data; terminating initial data load |
| 162 | Structure &1 cannot be edited; terminating program |
| 163 | Evaporation and reaction indicators cannot be selected at the same time |
| 164 | Enter the name of the XML file |
| 165 | File &1 cannot be read |
| 166 | Error occurred when transforming the XML file |
| 167 | Recipe header is being created |
| 168 | Identifiers are being created |
| 169 | Scopes of application are being created |
| 170 | Error in application; obsolete program is called |
| 171 | Stage formulas are being recalculated |
| 172 | Classification data is being created |
| 176 | Stage &1 is being created |
| 180 | Formula for stage &1 is being edited |
| 181 | Recipe formula is being edited |
| 190 | Recipe &1 created - &2&3 |
| 199 | Specification type &1 is not permitted in view &2 |
| 200 | -----Messages for Solver Call (Matrix Calculation)----------------------- |
| 201 | Error while calling the solver (matrix calculation): &1 |
| 210 | --------Messages for Error Handling During Unit Conversion--------------- |
| 211 | Error while converting units: &1, &2 formula &3 |
| 212 | Target input quantity does not exist; total of input quantities is used |
| 213 | Base quantity does not exist; total of output quantities is used |
| 214 | Standard unit for formulas does not exist in Customizing |
| 215 | Reference unit for &1 is not specified |
| 216 | Conversion is not possible; materials are not assigned to a specification |
| 217 | Total solids of specification &1 cannot be determined |
| 218 | Specify the density of aerated products for specification &1 |
| 219 | System cannot determine reconstitution rate |
| 220 | -----Messages for Loop Recording in Where-Used Graphic------------------- |
| 221 | Loop: Material &1 is input and output in formula &2 |
| 222 | Substance &1 is input and output substance in formula &2 |
| 223 | Material &1 is part of a multilevel loop |
| 224 | Multilevel loop: Substance &1 |
| 225 | Input material in &1, output material in &2 |
| 226 | Output material in &1, input material in &2 |
| 227 | Input substance in &1, output substance in &2 |
| 228 | Output substance in &1, input substance in &2 |
| 230 | Initial formula of explosion is different for substances and materials |
| 231 | Recipe has different primary outputs for substances and materials |
| 232 | Loading started for recipe &1 |
| 241 | Quantity entered is too large |
| 242 | Target input quantity or total input quantity (mass/vol.) does not exist |
| 243 | Specify a target input quantity |
| 244 | Edit the Ingredients formula view |
| 245 | Edit the Composition formula view |
| 246 | Total solids of primary output is greater than 100% |
| 247 | Value calculated for total solids % of primary output (spec.) > 100% |
| 248 | Value to be displayed for field &1, item &2 is too large (&3) |
| 249 | Value for structure frmls_iot_sum_value, field &1 is too large (&2) |
| 250 | Target input quantity was copied from calculated input quantity |
| 251 | Base quantity was copied from primary output |
| 252 | Target input quantity is not identical to the calculated input quantity |
| 253 | Edit the Nutrient Composition formula view |
| 254 | Value field (internal field name &1) is too small for determined value |
| 255 | Nutrient &1 (ingredient &2): Calculated value is too high |
| 256 | Nutrient composition was not written due to overflow |
| 301 | Both conversion factors were entered |
| 310 | XPRA--------------------------------------------------------------------- |
| 311 | RMS 2.1 is not installed in the system |
| 312 | RMS 2.2 is not installed in the system |
| 313 | Program ended |
| 314 | Program ended with errors; error messages have been generated |
| 315 | Runtime &1: &2 [ms] |
| 880 | Test messages (will be deleted before delivery)-------------------------- |
| 881 | Database does not contain a unit for the target input quantity |
| 900 | User-defined messages---------------------------------------------------- |