GHO_BO -
The following messages are stored in message class GHO_BO: .
It is part of development package EA_GHO_NETOBJ_BO in software component IS-OIL-UOM-MD. This development package consists of objects that can be grouped under "Network Objects: BO Layer".
It is part of development package EA_GHO_NETOBJ_BO in software component IS-OIL-UOM-MD. This development package consists of objects that can be grouped under "Network Objects: BO Layer".
Message Nr ▲ | Message Text |
---|---|
000 | Technical object & already exists |
001 | Network object & already exists |
002 | Enter all mandatory fields |
003 | Network object ID &1 is not created for object type 'well' |
004 | Network object ID &1 does not exist |
005 | Network object ID &1 does not exist |
006 | Well &1 is not assigned to well completion &2 |
007 | Network object ID &1 was not created for network object |
008 | Network object ID &1 already exists |
009 | Network object ID &1 was not created for object type 'well completion' |
010 | Network object ID &1 already exists for functional location |
011 | Enter all mandatory fields |
012 | Measuring point already exists for the given combination |
013 | Network object ID &1 is not created for object type 'well completion' |
014 | Network object ID &1 is not created for object type 'meter' |
015 | Network object ID &1 is not created for object type 'pump' |
016 | Network object ID &1 is not created for object type 'flare' |
017 | Network object ID &1 is not created for object type 'compressor' |
018 | Network object ID &1 is not created for object type 'turbine' |
019 | Network object ID &1 is not created for object type 'tank' |
020 | Network object ID &1 is not created for object type 'separator' |
021 | Make entry in mandatory field '&1' |
022 | Duplicate entry |
023 | Network object ID &1 is not assigned to a network |
024 | Duplicate planning data |
025 | Network object ID &1 is not created for object type 'production network' |
026 | Time zone &1 does not exist |
027 | Network object ID must not end with a separator |
028 | Entry length allowed in the edit mask has exceeded |
029 | QCI conversion not successful |
030 | Enter value for measurement parameter &1 |
031 | Location &1 does not exist in plant &2 |
032 | User &1 is editing network object &2 |
033 | Network object is too long |
034 | Only figures are allowed at position &1 |
035 | Entries value must contain numerical characters only |
036 | Parent well cannot be changed |
037 | IS-OIL tank object not yet assigned to the tank & |
038 | Only letters are allowed at position &1 |
039 | Enter field &1 |
040 | Entry not possible; medium '&1' is already assigned to production network |
041 | Enter the unit for &1 |
042 | One (or more) of the statuses &1 has the same 'valid from' date |
043 | Enter the &1 |
044 | Maintain the same units for fields &1 and &2 |
045 | &1 &2 has been marked for deletion |
046 | Entry not possible; frequency &1 is already assigned to prod. network |
047 | Entries in medium table deleted due to duplicate data |
048 | Entries in frequency table deleted due to duplicate data |
049 | External ID already exists |
050 | Value must not be greater than 100 |
051 | System ID &1 does not exist |
052 | Medium &1 is being used and cannot be deleted |
053 | Frequency &1 is being used and cannot be deleted |
054 | Value is not a valid number |
055 | Link &1 already exists |
056 | There is an existing link (&1) with the given start date and start time |
057 | Insert not allowed; neighbouring link (&1) has the same attribute |
058 | Action aborted |
059 | End date of link &1 is not changeable |
060 | End time of link &1 is not changeable |
061 | Change of the start date of the link &1 is not possible |
062 | Change of the start time of the link &1 is not possible |
063 | End date of link &1 adjusted automatically |
064 | End time of link &1 adjusted automatically |
065 | Link &1 is inserted |
066 | Link &1 is updated |
067 | Link &1 is deleted |
068 | Change not allowed; neighbouring link (&1) has the same attributes |
069 | Data not valid at &1 |
070 | Length of the value exceeded |
071 | Assign medium to the link |
072 | Deletion not allowed; there was an allocation run on the link &1 |
073 | End date of link &1 is not equal to the start date of link &2 |
074 | Maintain values in another unit of measure |
075 | Simulation mode |
076 | Prior Period Notification generated! |
077 | Name of Object ID &1 does not match with structure indicator type &2 |
078 | Inside diameter can not be greater than outside diameter |
079 | Outside diameter should be equal to sum of inside diameter and thickness |
080 | Field &1 is required |
081 | IS-OIL Tank ID &1 does not exist |
082 | Network object ID &1 is not created for object type 'manifold' |
083 | ******message for the update mass data******* |
084 | Enter Mandatory field - Network Object Type |
085 | Entered Network Object type should be &1 |
086 | Enter Structure Indicator |
087 | Enter Network Object ID |
088 | Network object ID &1 is not created for object type 'pipe' |
089 | Network object ID &1 is not created for object type 'heater treater' |
090 | Network object ID &1 is not created for object type 'dehydrator' |
091 | Enter the plant/storage location for IS-OIL Tank ID &1 |
092 | Enter description field |
093 | Network object ID &1 is not created for object type Generic |
094 | Choose the type of cluster object |
095 | Network object ID &1 is not created for object type Cluster Object |
096 | Meter type &1 is invalid |
097 | Meter operating mode &1 is invalid |
098 | Elevation reference type &1 is invalid |
099 | Life cycle status code &1 is invalid |
100 | Specified object ID format does not match the Structure Indicator &1 |
101 | Network Object ID &1 created |
102 | Network Object ID &1 updated |
103 | Simulation of creation of Net. Obj. ID &1 of type &2 completed |
104 | Simulation of updation of Net. Obj. ID &1 of type &2 completed |
105 | No Well Reference specified |
106 | Well completion type &1 does not exist |
107 | Compressor type &1 is invalid |
108 | Dehydrator type for object &1 invalid |
109 | Tank type &1 is invalid |
110 | Cluster object type &1 is invalid |
111 | Turbine type &1 is invalid |
112 | Pump type &1 is invalid |
113 | Entry &1 is taken from IFLOT table for Network object &2 |
114 | BAdI GHO_BADI_NETOBJ_BO is not implemented for object &1 |
115 | Functional location &1 does not exist |
116 | Cluster Object type not given |
117 | Generic Object type &1 is invalid |
118 | Generic Object type not given |
119 | Conversion Exit failed for object &1 |
120 | Authorization missing for activity &1 for transaction &2 |
121 | Files Read: &1; files processed succesfully: &2; invalid files: &3 |
122 | Total Network Objects read from directory path files: &1 |
123 | Enter time zone for production network |
124 | Enter a valid business day start time for production network |
125 | Incorrect file template used to upload objects of &1 type |
126 | No valid files found matching the given Network Object types |
127 | Use Copy From PM Floc option to update Net. object &1; see long text |
128 | Simulation of Link is not allowed using mass upload |
129 | Link &1 created successfully |
130 | Link &1 cannot be updated; updation is not allowed using mass upload |
131 | Cannot upload links using this option; use Upload (Create OPM objects) |
132 | Total network objects inserted: &1 |
133 | Total network objects updated: &1 |
134 | Total network objects with invalid data: &1 |
135 | Only Unicode Text format (*.TXT) files are supported for upload |
136 | Network/Cluster &1 does not exist |
137 | Cluster object &1 not used in production network modeling |
138 | &1 |
139 | Enter the frequency |
140 | Record Status Profile &1 does not exist |
141 | Record Status Profile &1 contains invalid characters |
142 | Custom Calculation ID &1 does not exist |
143 | Custom Calculation ID &1 does not exist for custom Allocation calculation |
144 | Audit Profile ID &1 doesn't exist |
145 | Custom Calculation ID &1,doesn't have a BAdI impl; see long text |
146 | Custom Calculation ID &1,BAdI implementation is not valid; see long text |
147 | Record Status Profile &1 cannot be changed. |
148 | Select valid User Status Profile for "&1" Record Status Profile |
149 | Overlapping link validity for same medium is not allowed |
150 | Audit Profile ID &1 does not belong to User Status Profile &2 |
151 | Production Network Hierarchy &1 does not exist |
152 | Tank volume is negative(&1 &2). Check open/close parameters |