I3 - PM Order Management and PM/SD Interface

The following messages are stored in message class I3: PM Order Management and PM/SD Interface.
It is part of development package IMSD in software component CS-SE. This development package consists of objects that can be grouped under "Configurable routing, PM/SD interface".
Message Nr
Message Text
000Specify complete key (maintenance plant and service object)
001Specify at least an order type and a work center
002Specify complete general maintenance task list key
003Specify a material number (KMAT)
004Enter a maintenance planning plant
005General maintenance task list &, alternative & not available or not valid
006Material & does not exist
007Matchcode search for service object ID & not supported
008Service object ID & not currently supported
009Specify reference type AND reference object type
010Specify reference object type
011No link to configuration
012Technical object configuration data was copied
013No entry for plant &, service object & & in table T399A
014Missing data for plant &, service object & & in table T399A
015Order type & not in table T0030
016Task list & & & does not exist or is not valid
017Specify complete key (maintenance plant, task list key)
018Plant & is not available
019Internal error during order generation
020Error occured during configuration (return code &)
021No instances (CUOBJ) were created
022Order & could not be deleted
023Order for object & not in internal order management
024Order & can not be displayed
025Error during order update
026Technical reference object for service object & & & is missing
027Enter a serial number
028Serial number & does not exist for material &
029Enter a material number
030No orders can be created (yet) for reference object type &
031Serial number missing
032Technical reference object & & (reference object type &) not found
033Configuration data could not be copied
034An order already exists for object &
035The status for order & can not be changed
036No technical reference objects can be specified for service & & &
037Incorrect reference object (type &) was specified for service & & &
038Internal error in object module management
039No technical reference objects exist
040A technical reference object must be entered for service & & &
041Entry of a technical object was cancelled
042Different sales offices in order and notification
043Different sales areas in order and notification
044Internal error: Order & has already been imported
045Interal error: Order & does not exist
046Order & could not be locked
047Internal error: Only real orders can be updated
048& & & &
049Order & could not be scheduled
050Dates for the existing order & can no longer be changed
051Order & could not be rescheduled
052Dates for order & remain up-to-date
053No order type for service object & & & in table T399A
054Refurbishment orders (order type &) are not supported
055Status & could not be set for order &
056Error during cost determination for order &
057Order type & is not suitable for repair processing
060Error during insert of RESTO records
061Error during number assignment for RESTO record
062Equipment & already locked, configuration data may not be current
063Internal error: Order for object & not in buffer table
064Internal error: Order for object & could not be updated
065Error during deletion of RESTO records
066Internal error: Temporary technical object not found
067Equipment & already reserved for object &
068Configuration of equipment & already in use (order &/&)
069Configuration of equipment & is already in use (item &)
070No configuration data found for CUOBJ &
071No configuration data was changed
072Internal error occured during configuration update, FuMo &
073Changes to configuration & are inconsistent
074Warning! Equipment & is reserved (sales order &, item &)
075Internal error: Order not specified for reservation
076Equipment configuration is reserved (sales order &, item &)
077Configuration of equipment & has changed (Order &/&)
078Configuration of equipment & has not changed (Order &/&)
079Internal error occured when changing equipment configuration
080Configuration of equipment & cannot be changed
081Change made to configuration of equipment & is inconsistent
082No valid combination of order type & and maintenance activity type &
083No order or maintenance activity type possible for service products
084Please specify at least one work center
085Only reference object category &2 is allowed for reference type &1
086Service order &1 will no longer be reconfigured
087Service order &1 could not be locked
088Configuration change to new equipment is inconsistent
089Error in copying configuration
090Error in copying configuration, reservation will be deleted
100Enter full key for PM/CS task list
101PM/CS task list & &, alternative & not available
102Order type & not specified for service
103Order type & not fully maintained
150Reference objects of category &1 cannot yet be created
151Reference object &1 could not be read
152The technical reference object for the order could not be created
153Entry of a sample equipment for service & & & obligatory
154Sales order & for service order & is already being processed by &
155Choose a configuration profile for object & (object ID &)
300No valid combination of order type & and maintenance activity type &
301Order template & is not a maintenance order
302Order template & does not have a settlement rule
303Error while determining the settlement rule
304Error & when copying the settlement rule
305Key of the service object (plant, ID + service object) is incomplete
306Internal error when updating the order data
307Maximum number of hierarchy levels = & exceeded
308Subordinate order could not be deleted
309Business transaction PMOC not allowed for reference object &
Privacy Policy