MPE_INSTALLATION_MSG -

The following messages are stored in message class MPE_INSTALLATION_MSG: .
It is part of development package MPE_INSTALLATION in software component PP-PEO. This development package consists of objects that can be grouped under "Manufacturing Plan & Exec - Installation Kits".
Message Nr
Message Text
000Network &1 does not exist
001Project &1 does not exist
002Select at least one record
003Networks not found
004Plant &1 does not exist
005Supervisor &1 does not exist
006You are not authorized to run report &1.
007Error while displaying
008New BOM version exists
009Parameter effectivity does not exist
010Networks for model/unit do not yet exist
011Networks do not have activities
012Released BOM not found
013Network effectivity not in range with BOM
014Latest BOM version not released
015BOM version is outdated
016A higher BOM version does not exist.
017BOM not exploded for network
018Network activity not yet released
019Inconsistent parameter effectivity
020Different networks of same project have different parameter eff. value
021The same parameter eff. value is used in different projects
022BOM item has no reference point
023No network activity with reference point &
024BOM item not in network�s components
025BOM item not in network�s components
026Reference point in BOM and routing differs
027A network activity with reference point has no components assigned
028BOM version is not latest
029Component not assigned to activity
030Reference activity does not exist
031Component assigned to activity without reference point
032Component not assigned to activity
033Referenced activity does not exist
034Component assigned to activity without reference point
035Component assigned to activity with wrong reference point
036Component not assigned to activity
037Referenced activity does not exist
038Component assigned to activity without reference point
039Component assigned to activity with wrong reference point
040Duration in network activity &1 and material master &2 differs
041Zero duration in network activity
042Component assigned to activity successfully
043Activity already exists. Components will be created.
044BOM items do not have parameter effectivity
045Parameter effectivity required by material but not defined in network
046Parameter effectivity not required by material but defined in network
047BOM is not version-controlled
048BOM version does not exist
049Entry & does not exist in MARA; check entry
050Plant & does not exist in table T001W; check entry
051BOM does not exist for material &1, plant &2, and usage &3
052Network demand (reservation) not in make-to-project planning section
053Alternative BOM does not exist
054Material type is not valid
055Project & created successfully
056Project could not be created
057Version BOM created successfully
058Order item not found
059Techs not updated at item level
060Project already exists
061Project ID not supported
062Network activity &1 starts before predecessor &2 is completed
063Network activity &1 ends before predecessor &2 ends
064Network activity &1 starts before predecessor &2 starts
065Material & is not an end item
066Network has comp. demand for major assembly, but network does not exist.
067Nested major assembly not connected to parent
068Activity not released and starts in the past
069Activity not completed and ends in the past
070Network has a reservation that is not in the BOM
071End item has a component that is not a major assembly
072Major assembly has a component that is not an installation kit
073Network activities have same reference point.
074Major assembly &1 has component &2, which is not an installation kit.
075No network exists for major assembly &1
076No BOM available at explosion date &.
077You are not authorized to display the selected networks.
078The networks of a nested major assembly
079&1 and its parent network &2 activity &3 are not connected by precedence
080&1 and its parent network &2 activity &3 are not connected by FF relation
081The networks of a nested major assembly are not connected by precedence.
082You are not authorized to create the project.
083New BOM version exists
084Requirement date of reservation &1 not aligned to end date of network.
085Major assembly &1 for network does not exist in BOM.
086Project updated successfully
087BOM not found
088Fill out all required entry fields
089Project exists for this parameter effectivity
090BOM not found for latest released version
091Provide parameter effectivity
092BOM usage &1 does not exist in table T416; check entry
093MRP controller &1 with plnt &2 does not exist in table t024d; check entry
094No data records found for these selection criteria
095Confirmation saved for network &1 activity &2
096Stock is posted for material &1, plant &2, network &3
097Project creation is allowed for serialized materials only
098No data found for selection criteria
099Project profile &1 not found
100Network profile not found for project profile &1
101Creation of project for nested major assembly is not allowed
102The components of an end item can only be major assemblies.
103No components found for end item &1
104No valid BOM components found for BOM &1
105Unable to create project since BOM &1 is recursive
106Planner group &1 with plant &2 does not exist in table T024A; check entry
107Network &1 of project &2 already updated
108Project &1 already updated
109No released version BOM found
110BOM &1 version &2 is not released
111Error while generating equipment number and serial number
112BOM and WBS element or network not yet selected for major assembly.
113BOM and WBS element not yet assigned.
114WBS element not yet assigned.
115Network not yet assigned.
116Project creation does not support Major Assemblies inside Major Assembly
Privacy Policy