MPE_MFGREF_STRUC - Message Class for MRS
The following messages are stored in message class MPE_MFGREF_STRUC: Message Class for MRS.
It is part of development package MPE_MFG_REF_STRUCTURE_BO in software component PP-PEO-MRS. This development package consists of objects that can be grouped under "Manufacturing Reference Structure - BO".
It is part of development package MPE_MFG_REF_STRUCTURE_BO in software component PP-PEO-MRS. This development package consists of objects that can be grouped under "Manufacturing Reference Structure - BO".
Message Nr ▲ | Message Text |
---|---|
000 | &1 &2 &3 &4 |
001 | Make an entry in one field only. |
002 | Reference object &1 already used in reference structure. |
003 | Reference structure &1 is already used. |
004 | MRS item &1 &2 is already used. |
005 | The reference object &1 used is obsolete. |
006 | The reference structure header &1 used is obsolete. |
007 | The MRS item used is obsolete. |
008 | The selected reference object group &1 does not exist. |
009 | The selected MRS usage &1 does not exist. |
010 | The selected reference object &1 does not exist. |
011 | You cannot set the obsolete status during the creation process. |
012 | Reference object of MRS item must differ from header reference object. |
013 | Material &1 does not exist. |
014 | BOM &1 does not exist. |
015 | MRS item &1 &2 does not exist. |
016 | Plant &1 does not exist. |
017 | MRS header &1 does not exist. |
018 | Header &1 cannot be changed because it is already assigned to BOM &2. |
019 | Item &1 cannot be changed because it is already assigned to BOM &2. |
020 | MRS assignment not possible: BOM &1 does not have status "In Process". |
021 | You must use the same MRS usage for assignment and reference path. |
022 | The MRS path does not exist. |
023 | Header assignment is not unique. |
024 | Root BOM &1 is used as a subordinate BOM in a path assigned to this MRS. |
025 | Leaf BOM &1 is used as a header BOM in a path assigned to this MRS. |
026 | Root MRS is used in a path. |
027 | Leaf MRS &1 is used in a path. |
028 | Enter data either for version BOM or non-version BOM. |
029 | Selected MRS item is used in root assignment. |
030 | Selected MRS item is used in leaf assignment. |
031 | BOM and subordinate BOM must differ. |
032 | You must enter a name of the MRS designator &1. |
033 | Assignment allowed only for serialized BOM. BOM &1 |
034 | The path contains non-serialized items (material &1, plant &2). |
035 | You do not have create authorization. |
036 | You do not have create authorization for usage &1. |
037 | Object &1 is used as an item. |
038 | The used object must be a root. |
039 | Object of item cannot be a root. |
040 | Object &1 invalid. Object ID must not contain spaces. |
041 | Specify an object ID. |
042 | Cannot delete MRS path or its items due to existing assignment |
043 | Reference structure item already used. |
044 | The entered authorization group does not exist. |
045 | Object of assigned item cannot be changed. |
046 | Hash value for path &1 is empty. |
047 | Path is not unique. |
048 | Cannot delete BOM path or its items due to existing assignment |
049 | You're not authorized to create assignments. |
050 | You're not authorized to update assignments. |
051 | You're not authorized to delete assignments. |
052 | Assignment cannot be changed. Order-specific routing already released. |
053 | Mapping of MRS to BOM item not allowed if component has visual instances. |
054 | BOM category does not exist. |
055 | You must specify a material. |
056 | You must specify a plant. |
057 | You must specify a BOM. |
058 | You must specify an alternative BOM. |
059 | You must specify an MRS usage. |
060 | You must specify an MRS header. |
061 | You must specify a BOM category. |
062 | You must specify inherited node number or inherited node number version. |
063 | You must specify an MRS designator. |
064 | You should not enter any blank or special symbol. |
103 | &1 &2 not found |
104 | Cannot find reference structure with usage &1 and object &2. |
105 | Cannot find material to BOM (&) link. |
106 | Cannot find MRS items with usage &1 and object &2. |
107 | MBOM &1 item not found |
108 | &1 assignment not found |
109 | Cannot find material path for MBOM &1. |
110 | Cannot find reference structure with usage &1 and object &2. |
111 | Cannot find MRS path with usage &1 and object &2. |
112 | &1 &2 successfully |
113 | Select an object type. |
114 | Enter a value without any spaces in the key field. |
115 | Enter only letters (A-Z) and numbers (0-9) in the key field. |
116 | Enter a value in the key field. |
117 | Error while executing the operation |
118 | A path with such items already exists. |
119 | No inherited node number exists for version-controlled BOM item. |
120 | No inherited node number exists for BOM item. |
121 | Error: &1 &2 &3 &4 |
122 | Invalid input data: &1 |
123 | Unable to define context for input hierarchy |
124 | Too many contexts for a root element |
125 | Check SFI_ID and PARENT_SFI_ID values. |
126 | Incorrect operation specified |
127 | No authorization to execute RFC &1 |
128 | No authorization to &1 &2 for group &3. |
129 | No authorization to display BOM &1. |
130 | There is no closing version for existing leaf assignment. |
131 | No authorization to &1 assignment |
132 | BOM &1 is already used in another root assignment. |
133 | &1 is a required input field. |
134 | Material path does not exist. |
135 | BOM &1 from material path is already used in root assignment. |
136 | BOM &1 from material path is already used in leaf assignment. |
137 | MRS object &1 from reference path is already used in leaf assignment. |