MPE_PLAN_EXEC - Message Class for Planning to Execution
The following messages are stored in message class MPE_PLAN_EXEC: Message Class for Planning to Execution.
It is part of development package MPE_PLAN_MSFMD in software component PP-PEO. This development package consists of objects that can be grouped under "Manufacturing Planning - Monitor Shop Floor Master Data".
It is part of development package MPE_PLAN_MSFMD in software component PP-PEO. This development package consists of objects that can be grouped under "Manufacturing Planning - Monitor Shop Floor Master Data".
Message Nr ▲ | Message Text |
---|---|
000 | Usage type could not be categorized |
001 | No valid source BOMs found |
002 | No date effective BOM found |
003 | No released planning BOM found |
004 | No changes found between planning BOM and shop floor BOM |
005 | Invalid BOM details |
006 | BOM usage does not support planning or shop floor execution |
007 | Usage for shop floor BOM has not been maintained |
008 | Usage for planning BOM has not been maintained |
009 | Source planning BOM does not exist for shop floor BOM |
010 | Valid from date is mandatory for date shop floor BOM |
011 | Error while determining BOM alternative for shop floor BOM |
012 | New shop floor BOM created successfully |
013 | Shop floor BOM updated successfully |
014 | New version of shop floor BOM created successfully |
015 | Usage supports planning and shop floor execution, which is not allowed |
016 | Error while inserting entries into hierarchy table |
017 | Effectivity type of & and & differ |
018 | Base UOM of &1 and &2 differ |
019 | Error while calculating effectivty intersection |
020 | No planning BOM found for phantom component &1 |
021 | Error while deleting hierarchy table entries |
022 | Error while updating hierarchy table entries |
023 | New shop floor BOM will be created |
024 | Shop floor BOM will be updated |
025 | New version of shop floor BOM will be created |
026 | Date effective BOM with phantom assembly is not supported |
027 | Error while determining change number for the shop floor BOM |
028 | No shop floor BOM found for update |
029 | Creation of shop floor BOM from planning BOM with visuals is not allowed |
030 | No BOM items found in the planning BOM |
031 | Error while building hierarchy of shop floor BOM |
032 | BOM item number exceeded the maximum limit |
033 | Overflow in BOM factor calculation for phantom component &1 |
034 | Recursive planning BOM is not supported |
035 | Usage for engineering BOM has not been maintained |
036 | No planning BOM found |
037 | No released planning BOM found for phantom component &1 |
038 | &1 is invalid BOM usage type |
039 | Error while updating BOM links |