PCF_REPOSITORY - Predefined Fields: Repository messages
The following messages are stored in message class PCF_REPOSITORY: Predefined Fields: Repository messages.
It is part of development package S_PCF_REPOSITORY_TRANSLATED in software component BC-SRV-APS-EXT-FLD. This development package consists of objects that can be grouped under "Predefined Fields: Translated Field Repository Objects".
It is part of development package S_PCF_REPOSITORY_TRANSLATED in software component BC-SRV-APS-EXT-FLD. This development package consists of objects that can be grouped under "Predefined Fields: Translated Field Repository Objects".
Message Nr ▲ | Message Text |
---|---|
000 | Internal Error |
001 | Configuration for Field &2 of Node &1 is not locked |
002 | Configuration for Field &2 of Node &1 could not be locked |
003 | Configuration for Field &2 of Node &1 is currently being edited by &3 |
004 | Configuration for Field &2 of Node &1 does not exist |
005 | Version &3 of Configuration for Field &2 of Node &1 does not exist |
006 | Configuration for Field could not be created, as it already exist |
007 | Configuration for Field could not be updated |
008 | Configuration for Field &2 of Node &1 could not be published |
009 | Configuration for Field &2 of Node &1 could not be deleted |
010 | Node name &1 is not valid |
011 | Predefined Field &2 of Node &1 is not valid |
012 | Field type must not be empty |
013 | Field type &1 is not valid |
014 | Field type must not be changed |
015 | Field type &1 requires a length definition |
016 | Field length must not exceed &1 |
017 | Field length must not be decreased |
018 | Field type &1 supports no length definition |
019 | Field scale must not exceed &1 |
020 | Field type &1 supports no scale definition |
021 | Master language must not be empty |
022 | Master language &1 is not valid |
023 | Master language must not be changed |
024 | Label and tooltip are missing in master language &1 |
025 | Language must not be empty |
026 | Language &1 is not valid |
027 | Label in language &1 is empty |
028 | Tooltip in language &1 is empty |
029 | Code list not supported for field type &1 |
030 | Code list must be defined |
031 | Code value &1 is too long. Maximum length is &2 |
032 | Active code value &1 must not be deleted |
033 | Code descriptions not supported for field type &1 |
034 | Code descriptions are missing in master language &1 |
035 | Description for code &1 in language &2 is empty |
036 | Code &1 of for description &2 in langauge &3 does not exist |
037 | Language for code &1 must not be empty |
038 | Language &1 for code &2 is not valid |
039 | CDS view entity &1 is not valid |
040 | Operation not permitted; missing authorization. |
041 | Label and tooltip are missing in language &1 |
042 | Code descriptions are missing in language &1 |
043 | Field &2 of Node &1 is not published. Publish it first |
044 | Field is externally used. Remove external usages first |
045 | Invalid field length &1 |
046 | Invalid field scale &1 |
047 | Field scale must not be decreased |
048 | Field scale must not exceed length of &1 |
049 | Field scale must not be increased differently than length |
050 | Code value &1 is not valid |
051 | Semantic type &1 is not valid for technical type &2. |
052 | Incompatible extensibility enabling. Please contact your software vendor. |