PPEWEB - Nachrichten zu Paket CPPEWEB
The following messages are stored in message class PPEWEB: Nachrichten zu Paket CPPEWEB.
It is part of development package CPPEWEB in software component AP-PPE. This development package consists of objects that can be grouped under "Web Accesses to PPE".
It is part of development package CPPEWEB in software component AP-PPE. This development package consists of objects that can be grouped under "Web Accesses to PPE".
Message Nr ▲ | Message Text |
---|---|
000 | The object is either not a node, or not of application object type 'GEN' |
001 | The node could not be read in & |
002 | Error reading the class in & |
003 | The node type is not recognized |
004 | The last messages could not be read |
005 | The message handler could not be read in & |
006 | The log could not be closed |
007 | The object is either not a node, or not of application object type 'CMP' |
008 | Error reading the relationships in & |
009 | No node has been found |
010 | The object is not a variant, or not of application object type 'CMP' |
011 | Missing input parameter: GUID has not been specified |
012 | Missing input parameter: OTYPE has not been specified |
013 | Missing input parameter: application object type has not been specified |
014 | Missing input parameter: language has not been specified |
015 | No variant has been found |
016 | No input parameters have been specified |
017 | Status not found |
018 | No Project System information found |
019 | No object dependencies have been read |
020 | No variant configuration has been read |
021 | No entry in the worklist |
022 | No favorites have been maintained |
023 | Invalid technical type |
024 | Object does not exist |
025 | No node or variant was found for this selection |
026 | The text for an object in the stack could not be read |
027 | There is no object in the stack |
028 | The short text for the node could not be read |
029 | The buffer could not be written to the database |
030 | No search criterion entered |
031 | There is no value specified for the first attribute |
032 | There is no value specified for the second attribute |
033 | No suitable object has been found for this search criterion |
034 | The attributes used in the search must be different |
035 | The message log could not be closed |
036 | The long text could not be read in & |
037 | The object dependency cannot be displayed on one line |
038 | No search criteria specified |
039 | Not all search hits are displayed; restrict the search criteria |
040 | The preconditions for the status could not be read in & |
041 | The values for the status could not be read in & |
042 | The short text for the status could not be read in & |
043 | Document does not exist |
044 | The description of the precondition could not be read in & |
045 | Status & could not be changed |
046 | Status & has been changed |
047 | The stack was not changed in the database |
048 | Change number could not be read |
049 | Text for document could not be read |
050 | Precondition &1 could not be changed |
051 | Precondition &1 has been changed |
052 | GUID and ID must be specified for the status you wish to change |
053 | ID for the precondition and GUID and ID for the status must be specified |
054 | Instance of the environment object could not be determined in & |
055 | PING could not be initialized in & |
056 | PING has not been executed in & |
057 | Variant could not be read in & |
058 | The description of the object could not be read in & |
059 | The inline text for the variant could not be read in & |
060 | The Customizing settings for the status values could not be read in & |
061 | Person responsible could not be read in & |
062 | Status could not be read in & |
063 | The information from the Project System could not be read in & |
064 | The linked documents could not be determined in & |
065 | Error reading the iPPE objects by administrative data in & |
066 | Could not read the information on user & |
067 | Error checking the variant in & |
068 | Error determining the iPPE object for the status in & |
069 | No iPPE object has been found for the status & |
070 | iPPE object has not been checked in & |
071 | Node does not exist |
072 | Failed to access database in & |
073 | The alternative in & could not be read |
074 | No variant has been found for change status & |
075 | There is no user with the name & |
076 | The list of favorites could not be completed |
077 | This object is already in the list of favorites |
078 | The worklist could not be completed |
079 | This object is already in the worklist |
080 | This favorites folder does not yet exist for user & |
081 | This worklist folder does not yet exist for user & |
082 | The Customizing settings for node type &1 could not be read in &2 |
083 | No folder has been specified |
084 | Entry has been saved |
085 | Entry has not been saved |