QECOPY - QM Data Transfer to an Inspection Lot
The following messages are stored in message class QECOPY: QM Data Transfer to an Inspection Lot.
It is part of development package QECOPY in software component QM-IM-RR. This development package consists of objects that can be grouped under "QM: Copy of Inspection Results into an Inspection Lot".
It is part of development package QECOPY in software component QM-IM-RR. This development package consists of objects that can be grouped under "QM: Copy of Inspection Results into an Inspection Lot".
Message Nr ▲ | Message Text |
|---|---|
| 001 | Data transfer to characteristic &1, operation &2 successfully completed |
| 002 | No data transfer to characteristic &1, operation &2 |
| 003 | Characteristic &1 of operation &2 was successfully completed |
| 004 | Characteristic &1 of operation &2 could not be completed |
| 005 | No automatic generation of defect record |
| 006 | InspLot/Operatn/Char. &1 was assigned to &2 for equipment &3 |
| 007 | InspLot/Operation/Char. &1 was assigned to &2 for functional loc. &3 |
| 008 | Inspection lot/operation/char. &1 was assigned to &2 for sample &3 |
| 009 | Inspection lot/operation/characteristic &1 was assigned to &2 |
| 010 | Data selection procedure &1 could not find any data |
| 011 | Inspection lot &1 found as data source |
| 012 | Data transfer is not planned for any characteristic |
| 013 | Data transfer not allowed for inspection type &1 (View V_TQEC30) |
| 014 | No inspection lot found for preliminary product |
| 015 | No suitable result found for insp. lot/characteristic/operation &1 |
| 016 | No active implementation exists for BAdI &1, procedure &2 |
| 017 | No active implementation exists for BAdI &1 |
| 018 | Data transfer will take place in characteristic &1 of operation &2 |
| 019 | Characteristic &1: Measurement unit &2 unknown |
| 020 | No equipment could be determined for the target inspection lot |
| 021 | No material sample could be determined for the target inspection lot |
| 022 | Char. &1 does not contain enough reference data for mapping procedure &2 |
| 023 | No data transfer allowed for the status of the characterstic &1 |
| 024 | Data transfer using menu function not allowed for inspection type &1 |
| 025 | Automatic defects recording not possible for char. &1 in operation &2 |
| 026 | Char. &1: It is not possible to process calculated characteristics |
| 027 | Not possible to confirm original values for characteristic &1 |
| 028 | Char. &1: Not possible to confirm the result for the sample |
| 029 | Characteristic &1 cannot be processed |
| 030 | Characteristic &1: Classed recording is not possible |
| 031 | Existence of insp. points is prerequisite for copy insp. results function |
| 032 | No result found for inspection lot/operation/char. &1 equipment &2 |
| 033 | No result found for inspection lot/operation/char. &1 funct. location &2 |
| 034 | No result found for inspection lot/operation/char. &1 sample &2 |
| 035 | Char. &1: No results confirmation planned for this characteristic |
| 036 | Different characteristic type for &1 and &2 |
| 037 | No functional location could be determined for the target inspection lot |
| 038 | You can only select one inspection point per operation |
| 039 | Copy to inspection point &1&2&3&4 |
| 040 | Copy from inspection point &1&2&3&4 |
| 041 | Calculated characteristic &1 of inspection lot &2 cannot be valuated |
| 042 | No single-value recording possible for charc &1 of inspection lot &2 |
| 043 | No recording possible for classed charc &1 of inspection lot &2 |
| 044 | Results recording not planned for charc &1 of inspection lot &2 |
| 045 | Characteristic &1 of inspection lot &2 cannot be processed |
| 046 | Error while changing status for charc &1 of inspection lot &2 |
| 047 | Summarized results recording not possible for charc &1 of insp. lot &2 |
| 048 | Sample cannot be completed for inspection lot &1 |
| 049 | No results can be confirmed for charc &1 of inspection lot &2 |
| 050 | Documentation required, closing not possible for charac &1 of lot &2 |
| 051 | Value '&1' cannot be interpreted as floating-point number |
| 052 | No single-value recording possible for calculated charc &1 of lot &2 |
| 053 | Forbidden attribute for update of calculated charc &1 of lot &2 |
| 054 | Calculated characteristic &1 of inspection lot &2 cannot be closed |
| 055 | Status 6 not possible for characteristic &1 of inspection lot &2 |
| 056 | Only "100" and "200" allowed for selection procedure |