QECOPY - QM Data Transfer to an Inspection Lot

The following messages are stored in message class QECOPY: QM Data Transfer to an Inspection Lot.
It is part of development package QECOPY in software component QM-IM-RR. This development package consists of objects that can be grouped under "QM: Copy of Inspection Results into an Inspection Lot".
Message Nr
Message Text
001Data transfer to characteristic &1, operation &2 successfully completed
002No data transfer to characteristic &1, operation &2
003Characteristic &1 of operation &2 was successfully completed
004Characteristic &1 of operation &2 could not be completed
005No automatic generation of defect record
006InspLot/Operatn/Char. &1 was assigned to &2 for equipment &3
007InspLot/Operation/Char. &1 was assigned to &2 for functional loc. &3
008Inspection lot/operation/char. &1 was assigned to &2 for sample &3
009Inspection lot/operation/characteristic &1 was assigned to &2
010Data selection procedure &1 could not find any data
011Inspection lot &1 found as data source
012Data transfer is not planned for any characteristic
013Data transfer not allowed for inspection type &1 (View V_TQEC30)
014No inspection lot found for preliminary product
015No suitable result found for insp. lot/characteristic/operation &1
016No active implementation exists for BAdI &1, procedure &2
017No active implementation exists for BAdI &1
018Data transfer will take place in characteristic &1 of operation &2
019Characteristic &1: Measurement unit &2 unknown
020No equipment could be determined for the target inspection lot
021No material sample could be determined for the target inspection lot
022Char. &1 does not contain enough reference data for mapping procedure &2
023No data transfer allowed for the status of the characterstic &1
024Data transfer using menu function not allowed for inspection type &1
025Automatic defects recording not possible for char. &1 in operation &2
026Char. &1: It is not possible to process calculated characteristics
027Not possible to confirm original values for characteristic &1
028Char. &1: Not possible to confirm the result for the sample
029Characteristic &1 cannot be processed
030Characteristic &1: Classed recording is not possible
031Existence of insp. points is prerequisite for copy insp. results function
032No result found for inspection lot/operation/char. &1 equipment &2
033No result found for inspection lot/operation/char. &1 funct. location &2
034No result found for inspection lot/operation/char. &1 sample &2
035Char. &1: No results confirmation planned for this characteristic
036Different characteristic type for &1 and &2
037No functional location could be determined for the target inspection lot
038You can only select one inspection point per operation
039Copy to inspection point &1&2&3&4
040Copy from inspection point &1&2&3&4
041Calculated characteristic &1 of inspection lot &2 cannot be valuated
042No single-value recording possible for charc &1 of inspection lot &2
043No recording possible for classed charc &1 of inspection lot &2
044Results recording not planned for charc &1 of inspection lot &2
045Characteristic &1 of inspection lot &2 cannot be processed
046Error while changing status for charc &1 of inspection lot &2
047Summarized results recording not possible for charc &1 of insp. lot &2
048Sample cannot be completed for inspection lot &1
049No results can be confirmed for charc &1 of inspection lot &2
050Documentation required, closing not possible for charac &1 of lot &2
051Value '&1' cannot be interpreted as floating-point number
052No single-value recording possible for calculated charc &1 of lot &2
053Forbidden attribute for update of calculated charc &1 of lot &2
054Calculated characteristic &1 of inspection lot &2 cannot be closed
055Status 6 not possible for characteristic &1 of inspection lot &2
056Only "100" and "200" allowed for selection procedure
Privacy Policy