QI - Notifications for interface modules for connecting subsyst.
The following messages are stored in message class QI: Notifications for interface modules for connecting subsyst..
It is part of development package QEIF in software component QM-IM-RR. This development package consists of objects that can be grouped under "QM interfaces inspection processing".
It is part of development package QEIF in software component QM-IM-RR. This development package consists of objects that can be grouped under "QM interfaces inspection processing".
Message Nr ▲ | Message Text |
|---|---|
| 000 | &1 inspection lot operation records were transferred |
| 001 | &1 characteristic records were transferred |
| 002 | Entry in work list table QIWL cannot be locked |
| 003 | Inspection lot is already locked |
| 004 | System error while locking inspection lot |
| 005 | Error while reading inspection lot |
| 006 | Error while reading plan header data for inspection lot |
| 007 | Selected set for inspection lot usage decison not found |
| 008 | Error while reading inspection lot operation records |
| 009 | Inspection lot operation not found |
| 010 | Cost center for work center not found |
| 011 | Error while reading purchasing info record |
| 012 | UD selected set used is not maintained in a plant |
| 013 | There are no inspection points in area &1 to &2 |
| 014 | Subsystem &2 starts function module &1 |
| 015 | Inspection lot table for status update is empty |
| 016 | Subsystem &2 ends function module &1 |
| 017 | Subsystem &3 triggers exception &1 in &2 |
| 018 | &1 entries were transferred to the worklist |
| 019 | -> Table &1 (Line &2) |
| 020 | A valuation was executed, although no indicators are set |
| 021 | You have no authorization to delete the application log for QM Interfaces |
| 022 | &1 application logs were deleted |
| 023 | Customer function &1 was run |
| 024 | You must set import parameter &1 |
| 025 | No valuation rules maintained |
| 026 | Customizing table for units to be inspected indicator inconsistent |
| 027 | No characteristics selected for operation |
| 028 | Error while reading short text for inspection method |
| 029 | Error while reading short text for characteristic weighting |
| 030 | Characteristic table empty - no status changes made |
| 031 | Characteristic table empty - no data transferred |
| 032 | No selection criteria entries found |
| 033 | - Parameter &1 = '&2' |
| 034 | - Table &1 not requested |
| 035 | - Table &1 (&2 entries) |
| 036 | Internal defect QM-IDI Interface |
| 040 | Selected set not released |
| 041 | Selected set does not exist |
| 042 | Version of selected set not available |
| 043 | Code has not yet been assigned |
| 044 | Code does not exist |
| 045 | Code group for selected sets code not available |
| 046 | Selected set for code not available |
| 047 | Code group not released |
| 048 | Code group does not exist |
| 049 | Version of code group not available |
| 050 | User &1 is not an SAPoffice user |
| 051 | The transmit module is not available |
| 052 | The folder is not available |
| 053 | No access to folder &1 (different owner/no authorization) |
| 054 | The specified forwarding party does not exist |
| 055 | The specified note does not exist |
| 056 | The specified object does not exist |
| 057 | The specified object was not sent to a receiving party |
| 058 | No authorization to send the specified object |
| 059 | The specified object type is unknown |
| 060 | No authorization to send |
| 061 | The specified responsible party/owner does not exist |
| 062 | The combination of specified parameter values is not allowed |
| 063 | Active user is a representative but is not activated |
| 064 | Active user not defined as a representative |
| 065 | Specified user does not exist |
| 066 | X_ERROR activated by transmit module |
| 070 | A plant must be specified before an inspection point ID can be determined |
| 071 | No inspection point identifications are maintained for plant &1 |
| 072 | Unplanned characteristic &1 does not exist for inspection point &2 |
| 080 | No communication destination maintained for subsystem & |
| 081 | No entry found in subsystem table for & |
| 082 | Table structure & too long for transfer |
| 083 | An invalid data type has been used in table structure & |
| 084 | Error creating a receiver file |
| 085 | Insufficient main storage available |
| 086 | Error accessing RFC transfer tables |
| 087 | Error creating the interchange files |
| 088 | Interchange files are already present in the target system |
| 089 | Interchange files are not available in the subsystem |
| 100 | ---- Notifications results confirmation QM-IDI interface |
| 101 | Incorrect record type for results recording for confirmation number & |
| 102 | Field & in record for confirmation number & contains incorrect characters |
| 103 | System error while locking |
| 104 | Characteristic with confirmation number &1 is already blocked by user &2 |
| 105 | Characteristic with confirmation number & is not available |
| 106 | Characteristic lot with confirmation no. & not available |
| 107 | Operation for characteristic with confirmation no. & not available |
| 108 | Sample & for characteristic with confirmation no. & not available |
| 109 | Valuation module for confirmation no. & not available |
| 110 | No serial number indicated for confirmation number & |
| 111 | Error while changing status for characteristic w/confirmation no. & |
| 112 | Incomplete record for confirmation no. & : no measured value indicated |
| 113 | Incomplete record for confirmation no. & : no code indicated |
| 114 | Incomplete record for confirmation no. & : no valuation indicated |
| 115 | Record error for confirmation no. & : code & for codeGrp & not available |
| 116 | Record type &1 does not match confirmation of characteristic &2 |
| 117 | Single result &1 for characteristic w/confirmation no. &2 not available |
| 118 | Characteristic w/ confirmation no. & could not be closed |
| 119 | Characteristic w/ confirmation no. & could not be valuated |
| 120 | Sample &1 for characteristic with confirmation no. &2 is not closed |
| 121 | Sample &1 for characteristic w/confirmation no. & could not be valuated |
| 122 | Defect class &1 of characteristic w/confirmation no. & not defined |
| 123 | Valuation &1 of characteristic for confirmation no. &2 not allowed |
| 124 | Defect class &1 of characteristic w/confirmation no. &2 not defined |
| 125 | Valuation &1 for sample &2 and confirmation no. &3 is not allowed |
| 126 | Defect class &1 for sample &2 and confirmation no. &3 not defined |
| 127 | Sample &1 for characteristic w/confirmation no. &2 is not valid |
| 128 | Sample &1 for characteristic with inspection charac. &2 was not specified |
| 129 | No samples are permitted for characteristic w/confirmation no. & |
| 130 | Confirmation for characteristic & not allowed in view of inspLot status |
| 131 | No authorization for insp. type or material for insp. characteristic &1 |
| 132 | No operation authorization for characteristic with confirmation no. &1 |
| 133 | No single unit number specified for comp. conf. no. & |
| 134 | No serial number maintenance for completion confirmation number & |
| 135 | Valuation in QM resulted in inspection characteristic & being rejected |
| 136 | Valuation in QM resulted in sample &1 for charac. &2 being rejected |
| 137 | Serial number missing for characteristic &1 |
| 138 | The status conversion of characteristic &1 was unsuccessful |
| 139 | Single value &1 was not copied for confirmation number &2 |
| 140 | ----- Notifications usage decision confirmation QM-IDI |
| 141 | Incorrect record type for usage decision confirmation lot &1 |
| 142 | Number of inspection lot &1 is not set in confirmation record |
| 150 | ----- Notifications: Inspection point confirmation QM-IDI |
| 151 | Record type &1 for inspection point confirmation not supported |
| 152 | Inspection point &1 of characteristic &2 is not available |
| 160 | Notifications for file interface |
| 161 | Function module number & not permitted |
| 162 | The interchange files could not be deleted on the subsystem |
| 163 | Temporay files cannot be created on the subsystem |
| 164 | Inter-process communication error |
| 165 | Shared memory error on subsystem |
| 166 | Hash management error on subsystem |
| 167 | Transfer files cannot be deleted on the subsystem |
| 168 | Entries missing in the DDIC.dat file on the subsystem |
| 170 | &1 errors were confirmed during the transfer of usage decision records |
| 171 | &1 errors were confirmed during the transfer of charac. result records |
| 172 | &1 errors were confirmed during the transfer of sample result records |
| 173 | &1 errors were confirmed during the transfer of single result records |
| 174 | &1 errors were confirmed during the transfer of inspection point records |
| 175 | Record type &1 not planned for defect confirmation |
| 176 | You must enter an inspection lot for this record type |
| 177 | You must enter an operation for this record type |
| 178 | You must enter a characteristic for this record type |
| 179 | Enter a sample number for this record type |
| 180 | Field POSNR contains an invalid value |
| 181 | Field ANZFEHLER contains an invalid value |
| 182 | Value '&1' in field '&2' is not allowed |
| 183 | Inspection lot is locked by another user |
| 184 | You cannot enter an operation for record type Q90 |
| 185 | You cannot enter a characteristic (MERKNR) for record type &1 |
| 200 | ---- Notifications: plausibility checks |
| 201 | &1 is not a correct date |
| 202 | &1 is not a correct time |
| 301 | Incorrect record type for results recording for confirm. no. &1 lot &2 |
| 302 | Field &1 in record for confirm. no. &2, lot &3 contains incorrect chars |
| 304 | Characteristic with confirmation number &1 (lot &2) is blocked by user &3 |
| 305 | Characteristic with confirmation number &1 (lot &2) is not available |
| 306 | Characteristic lot with confirmation no. &1 (lot &2) not available |
| 307 | Operation for charc with confirmation no. &1 (lot &2) not available |
| 308 | Sample &1 for charc with confirmation no. &2 (lot &3) not available |
| 309 | Valuation module for confirmation no. &1 (lot &2) not available |
| 310 | No serial number entered for confirmation number &1 (lot &2) |
| 311 | Error when changing status for charc with confirmation no. &1 (lot &2) |
| 312 | Incomplete record for confirm. no. &1 (lot &2): no measured value entered |
| 313 | Incomplete record for confirmation no. &1 (lot &2): no code entered |
| 314 | Incomplete record for confirmation no. &1 (lot &2): no valuation entered |
| 317 | Single result &1 for charc with confirm. no. &2 (lot &3) not available |
| 318 | Characteristic with confirmation no. &1 (lot &2) could not be closed |
| 319 | Characteristic with confirmation no. &1 (lot &2) could not be valuated |
| 320 | Sample &1 for characteristic (confirmation no. &2, lot &3) is not closed |
| 321 | Sample &1 for charc (confirmation no. &2, lot &3) could not be valuated |
| 322 | Defect class &1 of charc with confirmation no. &2 (lot &3) not defined |
| 323 | Valuation &1 of charc for confirmation no. &2 (lot &3) not allowed |
| 324 | Defect class &1 of charc with confirmation no. &2 (lot &3) not defined |
| 325 | Valuation &1 for sample &2 confirmation no. &3 (lot &4) is not allowed |
| 326 | Defect class &1 for sample &2 confirmation no. &3 (lot &4) not defined |
| 327 | Sample &1 for characteristic w/ confirmation no. &2 (lot &3) is not valid |
| 329 | No samples are permitted for charc with confirmation no. &1 (lot &2) |
| 332 | No operation authorization f. characteristic (confirmation no. &1 lot &2) |
| 333 | No single unit number specified for confirmation no. &1 (lot &2) |
| 334 | No serial number maintenance for confirmation number &1 (lot &2) |
| 339 | Single value &1 was not copied for confirmation number &2 (lot &3) |