001Inspection object type cannot be deleted; inspection rules are assigned
002Inspection object type is already being processed by user &1
003Inspection rule is already being processed by &1
004Inspection rule is in display mode; you cannot make changes
005No authorization for activity &1 for inspection rule
006Sample size has not been specified
007Sampling scheme has not been specified
008You must specify an inspection severity for sampling scheme &1
009You must specify an inspection level for sampling scheme &1
010You must specify an AQL value for sampling scheme &1
011No dynamic modification criteria have been specified
012Dynamic modification criteria &1 are not valid for insp. object type &2
013No decision code group has been specified
014No sampling type specified
015No inspection procedure specified
016An inspection object type with the identification &1 does not exist
017Inspection object type is in display mode; changes are not possible
018Names of properties must be unique
019Specify the name of the property
020Properties cannot be changed; inspection rules are assigned
021No index ID has been specified
022No properties have been specified
023Property &1 is not defined in the inspection object type
024Property &1 cannot be deleted; an index exists
025Sampling scheme &1 is locked
026Dynamic modification rule &1 is locked
027Dynamic modification criterion &1 is locked
028Decision code group &1 is locked
029Property &1 cannot be used for inspection rules
030Specify a number range for inspection documents in the inspection rule
031Sample type &1 is not valid for inspection object type &2; select other
032Sample type &1 is locked
033Sample-drawing procedure &1 is locked
034You must specify an interval for the sample-drawing type
035Technical name of property &1 contains impermissible special characters
036External quality management system &1 is locked
037Finding type &1 is locked
038&1 is an item type; however, you need to specify a sample type
039Assignment to a document of type &1 already exists
040Inspection rule cannot be deleted; dependent inspection rules exist
041Define a property type for the property &1
042Specify a sample type for the specified sample-drawing procedure
043Specify a decision code group for samples
044Specify a decision code group for items
045Sample type &1 does not exist
046Specify a (fixed) sample size
047Specify a sample size (in percent)
048Insp. rule args are not practical for inspection procedures "No Insp."
049Sample args are not practical for inspection procedures "100% Inspection"
050Insp. severity &1 from dyn.mod.rule &2 does not exist in samp. scheme &3
051Arguments specified for sample type 1 are not suitable for sample type &1
052Arguments specified for sample type 2 are not suitable for sample type &1
053Arguments specified for sample type 3 are not suitable for sample type &1
054Rule specified for sample determination not suitable for sample type &1
055Sample-drawing unit overridden by container type in sample-drawing proc.
056Sample-drawing procedure of type BAdI does not contain sample-draw. unit
057No automatic release of samples despite external system being specified
058Item type &1 not permitted for inspectn obj. cat. &2; Select another