QPCP - Control Plan

The following messages are stored in message class QPCP: Control Plan.
It is part of development package QPCP in software component QM-PT-CP. This development package consists of objects that can be grouped under "QM: Control Plan".
Message Nr
Message Text
000----------------- Control Plan Error Messages ------------------------
001An internal error occurred in the application
002You do not have the authorization to execute this function
003Internal error when executing authorization check
004There is no authorization profile stored in the user master record
005An authorization is damaged in the user master record
006Status management does not permit you to execute function &1
007The control plan is closed
008Internal error in status management
009User &1 is already processing control plan &2
010System error occurred during the locking procedure
011Control plan with number &1 does not exist
012Control plan &1 was saved
013Control plan &1 has not been changed and was not saved
014Errors occurred when saving the control plan
015Control plan &1 already exists
016Plan group counter &1 is not available for plan group &2
017Control plan identifier &1 protected
018Select a plan type
019The SAVE method was called without COMMIT WORK
020Control plan no longer available
021Control plan items are not (not all) available
022Control plan links are not (not all) available
023Control plan partner are not (not all) available
024Select exactly one object in the table
025Link type &1 is not supported
026Material &1 was not found
027There is no BAdI implementation for object category &1
028Error in change document creation/analysis: & &
029No change documents found
030Control plan is consistent
031&1 FMEAs were copied to the control plan
032No BOM available for material &1
033Enter a FMEA
034There are no characteristics available
035Sort number &1 already exists
036'Role' field cannot be deleted
037Specify a control plan
038Interface type is not compatible with Adobe forms
039Item &1 already exists for the control plan
040There is no BOR object available in simulation mode
041Classed recording is switched off for characteristic &1
042You do not need to assign test equipment for characteristic &1
043Characteristc &1 is not distinguished as a formula
044Select at least one row in the table
045First select a characteristic origin
046First select a source object
047First copy a source object characteristic
048Source object &1 of type &2 does not exist
049Enter a characteristic number
050Error when loading plan (&1)
051Error when reading FMEAs
052Error when reading the operations
053Error when reading the work center/inspection center
054Error when reading the characteristics
055Object &1 for process &2 of object &3 is missing
056Object type &1 does not exist
057Error when loading the quality info record &1
058Error when loading document &1
059Error when loading control plan item &1
060Could not save characteristic
061Characteristic was saved successfully
062Could not find object for object category &1
063Consistency check for copying characteristics was successful
064Number &1 not in valid area of number range &2
065External numbering is not planned for number range &1
066Select at least one characteristic in the source object
067Select exactly one operation in plan
068Select at least one characteristic in the plan
069Could not remove at least one of the selected entries
070Number in number range interval &1 (&2 to &3)
071Error while reading the notification
072FMEA &1 already archived
073Could not copy some subobjects
074Characteristic &2 from FMEA &1 is not part of the control plan
075Lower-level FMEA &2 for FMEA &1 is missing in the FMEA overview
076FMEA &1 has status &2 and is therefore not copied
077FMEA &1 has status &2
078Could not copy some FMEAs
079FMEA &1 is already assigned to the control plan
080FMEA &1 of structure has not yet been copied
081Status profile &1 does not exist
082Enter a template
083Cannot find project number &1 in cProjects
084Item was created with number &1
085Could not find a RFC connection to a cProjects system
086Message log for operation &1, characteristic &2
087The FMEA does not contain the FMEA char. &1 of inspection char. &2
088Inspection char. &1 from plan &2 links to a deleted FMEA characteristic
089A control plan could not be created based on your entries
090Plan creation date must not be greater than selection date
099---------------------- CP Customizing Error Messages -----------------
100There are no Customizing entries for the specified structure type &1
101There is no text in language &2 for structure type &1
102No Customizing for structure type &1, object type &1, process type &3
103No text in language &2 for process type with the key &1
104There are no Customizing entries for structure type &1, object type &2
105There is no text in language &3 for structure type &1, object type &2
106No text exists in language &2 for object category &1
107There are no Customizing entries for the specified plan type &1
108There is no text in language &2 for plan type &1
109No text exists in language &2 for process category &1
110No Customizing for struc. type &1, obj. type &2, process type &3, obj &4
111No Customizing for selection area: Key &1
112No Customizing for selection field with key &1
113No object type in Customizing for structure type &1 and object cat. &2
114There are no Customizing entries for characteristic origin
120Could not find a plan for the data entered
200Control plan status does not permit you to create an object link
300******* Messages for Selection Log *****
301&1: Selection with following values: &2 &3 &4
302&1: Selection not possible. Missing values for: &2 &3 &4
303No selection log available
304Process category &1 is not relevant for material &2
305Cannot find task list/inspection plan for key date &1
306Selection date &1 is before today's date
Privacy Policy