QPVP -

The following messages are stored in message class QPVP: .
It is part of development package QPVP_BO in software component QM-PT-VP. This development package consists of objects that can be grouped under "Business Object Access for Visual Planning".
Message Nr
Message Text
000Enter a valid material and plant.
001Group number already exists. Enter another group number.
002Enter a valid group number.
003Enter a valid group number.
004Material not associated with the group number.
005Enter a valid status.
006Select a valid planner group.
007Task list has been checked. It can be created.
008Task list has been checked. It can be edited.
009Could not edit task list. Check the message log.
010Maintain a value for control key &1 in customizing T430.
011Could not create or modify task list. Check the message log.
012Key date was overwritten with date &1 from change number.
013Could not create inspection plan. Check the message log.
014Could not modify inspection plan. Check the message log.
015No viewable file was found for the material.
016Enter a valid task list type.
017Select an operation.
018Select a single operation.
019You are not authorized to view or modify the task list.
020Document version of the material has changed.
021Task list could not be locked for your user.
022Enter a valid usage.
023Enter a valid status.
024Enter a control key for operation &1.
025No material is associated with group number &1.
026Enter a material and plant associated with Grpno. due to multiple entries
027Enter a valid task list type.
028Comparison of inspection characteristics is completed.
029Preset indicator &1 cannot be used for a quantitative characteristic.
030Preset indicator &1 cannot be used for a qualitative characteristic.
031Invalid preset indicator &1. Enter a valid value.
032No model views selected
033You are not authorized to view or modify the task list.
034Task list is marked for deletion.
035Switch on the business function OPS_QM_VP.
036Node information from the viewable file could not be transferred.
037Char. could not be created in line &1. Re-enter char. ID and oper. ID.
038Enter the control key for oper. &1. Char. in line &2 not created.
039Enter a valid target value.
040Enter a valid tolerance key.
041PRT &1 cannot be deleted as it is assigned to an inspection char.
042Material &1 does not exist in plant &2.
043Operation ID should be a numeric value.
044Select a valid task list type.
045Select a usage value in header details.
046Select a status in header details.
047&1 characteristics were created. &2 characteristics were modified.
048Enter the control key for operation &1.
049Enter a valid master insp. char. plant for characteristic &1.
050Master insp. char. &1 in plant &2, and version &3 not found.
051Master insp. char. &1 in plant &2, and version &3 is locked.
052Select a single characteristic.
053Select an operation or a char. to transfer nodes from the viewable file.
054Select an operation or a char. to transfer nodes from the viewable file.
055Select only one node in the file and one insp. char. to transfer.
056Inspection char. &1 of operation &2 will be overwritten.
057Files are not retrieved as no material or characteristic ID is passed.
058Excel is already open. Could not over-write the contents.
059No inspection plan found for selected material.
060No inspection plan found for selected material or plant.
061Enter a valid test equipment.
062No inspection plan selected.
063Enter a valid inspection method, version, and plant.
064Enter a valid inspection method plant.
065Enter a valid inspection method.
066Enter a master insp. char., version, and plant to use the MIC template.
067Enter a sample unit of measure.
068Enter a valid inspection method version.
069Operation ID &1 is not valid. Select a valid operation.
070Characteristic ID should be a numeric value.
071Select an operation to auto-generate characteristic ID.
072Maintain an interval in the number range object QPVP_ID.
073Maintain an internal number range in the number range object QPVP_ID.
074Number range object QPVP_ID is not defined.
075Number range object QPVP_ID could not generate a number.
076Number range object QPVP_ID could not generate a number.
077Number range object QPVP_ID interval is used up.
078Number range object QPVP_ID could not generate a number.
079Number range object QPVP_ID could not generate a number.
080Multiple materials are associated with group number &1.
081Your action was cancelled.
082PMI characteristics already exists with a different operation
083The characteristic values will be overwritten from the selected node.
084One or more selected nodes already linked to an existing char.
085Node &1 linked to characteristic &2 of operation &3.
086Select a node from the viewable file to transfer the characteristics.
087Characteristic is not linked to any node in the current viewable file.
088&1 nodes could not be transferred. Check the message log.
089Node &1 does not have VE identifiers.
090Node &1 does not have VE identifiers, CAD_ID, and PMI_UID.
091Select only one node when updating an existing characteristic.
092Enter a char. description for operation &1 char. &2 sequence &3.
093Error validating unit of measure, check the message log.
094Enter a valid unit of measure for node &1 of operation &2 and char &3.
095You are not authorized to change inspection plan
096You are not authorized to create inspection plan
Privacy Policy