QY - QM: Sample management

The following messages are stored in message class QY: QM: Sample management.
It is part of development package QPR in software component QM-IM-SM. This development package consists of objects that can be grouped under "QM sample management".
Message Nr
Message Text
000*** S A M P L E M A S T E R R E C O R D ***
001Table TQ01 is not maintained for transaction &1
002Sample &1 was not created yet
003Changing sample &1
004No changes were made
005Error in status management &1
006Creating sample &1
007Sample-drawing record &1 does not exist
008No change documents exist
009Sample &2 is already being processed by user &1
010Sample &1 cannot be processed (system error)
011Print module for sample type &1 could not be found
012Status " &1 " was set
013Status " &1 " was reset
014Sample &1 was already created
015Overwriting previous text for sample drawing
016Data changes saved
017Enter either a sample type or choose 'New Sample with Copy Model'
018Choose 'New with copy model' or 'Extend existing'
019Choose "New without copy model" or enter the number of the copy model
020You must enter a sample drawing number for the copy model
021You must enter a sample drawing number to add the master record
022No samples are assigned to inspection lot &1
023Sample label was successfully printed
024Sample-drawing procedure &1 was already confirmed on &2
025No samples are assigned
026You must enter a sample type for this sample drawing
027You must enter a batch for material &1
028Copying data from the material document
029Copying inspection lot &1 from material document
030Copying inspection lot &2 from order &1
031Copying data from order &1
032You must enter a material number
033Sample number &1 is not in the external number range 00.
034Sample number &1 was already allocated
035No sample type is assigned to inspection type &1
036Maintain the sample quantity completely (quantity and unit)
037No samples were created for sample drawing &1
038No sample drawing is planned for inspection lot &1
039Inspection lot &1 not found
040Please confirm sample drawing &1
041You cannot process sample drawing in test or display mode
042Sample &1 does not have the required status
043Insp. sample for last insp. lot &1 for sample &2 not yet calculated
044Material is not known for sample &1
045Unit &1 cannot be converted into base unit of measure for the material
046Inspection lot &1 for sample &2 successfully created (return code &3)
047Please rework inspection lot &1 for sample &2 (return code &3)
048No inspection lot can be created for sample &1 (return code &2)
049Quantity is not recognized for sample &1
050Enter either an inspection lot, order number or production version number
051Number of samples to be generated must be greater than 0
052No inspection lot exists for order number &1
053Cannot find repetitive manufacturing &1, &2, &3
054Usage decision has already been made for inspection lot &1
055Inspection lot &1 does not allow for an inspection of samples
056Inspection type for origin 15 is not active for material &1/&2
057Internal error during label printing
058Cannot find inspection lot for repetitive manufacturing &1, &2, &3
059Storage location &1 is not defined for plant &2 of sample &3
060Sample &1 is blocked and is already being changed
061Sample &1 has not changed
062No characteristic specifications found for the operation/operations
063Enter the quantity and unit of measure for the sample
064Sample drawing &1 does not belong to the current inspection lot
065You cannot set and reset a status at the same time
066Confirmation of sample drawing was canceled
067You can only confirm sample drawing in dialog mode
068Import parameters not correct: &
069The sample for an existing item cannot be changed
070Status 'All Inspections Completed' already set for inspection lot &1
071An open lot or long-term inspection characteristic exists for sample &1
080Quantity is too small for sample &1; no is lot created
200* * * S A M P L E D R A W I N G P R O C E D U R E * * *
201You are not authorized to process other samp. draw. procs. in the system
202An internal error occurred during the authorization check
203There is an error in the user authorization for the user record
204Update canceled (mode &1, table &2, run-chart &3)
205You cannot make any more new entries
206You can only process long texts in the 'display' and 'change' modes
207No long text exists
208Enter a valid inspection severity
209Enter a valid AQL value
210Calculation according to a sampling scheme, formula, or fixed number
211Enter the missing information
212Error when processing long text
213Error in copying a long text
214You are not authorized to process this authorization group
215You did not enter instructions for the first stage/primary stage
216The sample-drawing procedure cannot have an initial value
217No long text exists
218The sample drawing procedure is being used and cannot be deleted
219Table/view &1 is not in cluster &2
220Internal error (view cluster has not been initialized)
221View cluster & does not exist
222Do not use a blank in the key &
223Do not use leading zeros
224You cannot use sample drawing procedure &
225Define the sample drawing procedure &
226There are no instructions for sample drawing procedure &1 &2
227Sample drawing procedure &1, &2 is not defined
228Error during update of change documents
229Use the transaction & to avoid data inconsistencies
230Enter a factor greater than or equal to 1
231An entry already exists with the same key
232Sampling scheme &1 cannot be used in sample-drawing procedure
233Sampling scheme &1 does not exist
234Error occurred during check of sampling scheme &1
300**** S A M P L E D E T E R M I N A T I O N F O R I N S P. L O T
301Sample draw. proc. &1 not found for sample determination in insp. lot &2
302Error during determination of elementary samples in insp. lot &1
303Lot &1: No sample-drawing items found for sample-drawing procedure &2, &3
304Sample determination: No sample drawing item found
307Samp. determination: Data missing for no. of containers and lot container
308Sample drawing item no longer exists
309Total size of all material samples is greater than the lot size
310More than one sample-drawing item was found for operation &1
311No material sample exists for inspection lot creation
312Enter no. of containers and lot container (container requirement in QM)
313Formula must determine a number of samples greater than 0
314Overflow during sample determination
Privacy Policy