RJ - Nachrichtenklasse BW-Extraktorenhandling
 The following messages are stored in message class RJ: Nachrichtenklasse BW-Extraktorenhandling.
It is part of development package RSU1 in software component BC-BW. This development package consists of objects that can be grouped under "BW Service API: Tools and Generic Extractors".
 It is part of development package RSU1 in software component BC-BW. This development package consists of objects that can be grouped under "BW Service API: Tools and Generic Extractors".
| Message Nr ▲ | Message Text | 
|---|---|
| 000 | ******** Messages for Extractor Test Tool ************************** | 
| 001 | Template class not available (entry in table RSSGTPCLA) | 
| 002 | DataSource & is not defined in the source system | 
| 003 | Extractor &1 not available (table TFDIR) | 
| 004 | &1: TABLES-paramter &2 for extractor &3 is missing | 
| 005 | Extractor &: Initialization error | 
| 006 | Extractor &: No data available | 
| 007 | & data records selected | 
| 008 | Error & during extraction | 
| 009 | Specify an object type | 
| 010 | InfoObject: Metadata error | 
| 011 | & data records have been extracted | 
| 012 | Errors occurred during the extraction | 
| 013 | Initialization error | 
| 014 | No data was found | 
| 015 | InfoObject &: Missing entry in table RODCHABAS | 
| 016 | No list exists | 
| 017 | List is empty | 
| 018 | No authorization for checking extractors (error &1) | 
| 019 | No generated transfer structure exists | 
| 020 | Data type not supported by source system | 
| 021 | No information for this language | 
| 022 | Was not able to call the Service-API | 
| 023 | No mapping exists for the DataSource | 
| 024 | Field & is a mandatory selection field, and cannot be deleted | 
| 025 | No transfer rules for target system & | 
| 026 | Field &1 in the provider structure is missing from extract structure &2 | 
| 027 | No DataSource exists | 
| 028 | Error &1 in function module &2 | 
| 029 | Extractor was not found | 
| 030 | An error occurred during the extraction of InfoSource & | 
| 031 | Start date for the selection has to be scheduled for after 01.01.1000 | 
| 032 | Extractor checker is not set up correctly | 
| 033 | Extract structure & is not active | 
| 034 | No extractor exists | 
| 035 | Extractor & raises an invalid exception | 
| 036 | Do not use a projection view in a pool/cluster table | 
| 037 | Extraction from pooled tables and cluster tables is not permitted | 
| 038 | &: Checking extraction properties ... | 
| 039 | Table & is missing from the extractor interface | 
| 040 | Domain fixed values are extracted only from text-DataSources | 
| 041 | Domain & is not active | 
| 042 | DataSource &1 is extracted using functional module &2 | 
| 043 | Missing 1.2 metatdata for &. This metadata is essential fr the extraction | 
| 044 | &: Only tables and views are permitted for extraction | 
| 045 | Unit field &1 of field &2 is not in the view | 
| 046 | DataSource is in SAP namespace | 
| 047 | Parameter &1 is missing in extractor &2 for DataSource &3 | 
| 048 | Unclear whether extractor can extract delta in test mode | 
| 049 | The update mode 'C' (DeltaInit) cannot be tested | 
| 050 | The DataSource & still has no target system for the delta update | 
| 051 | &1: Error in subroutine &2 | 
| 052 | Request &1 does not exist in BW &2 | 
| 053 | & | 
| 054 | Error with RFC access to system & | 
| 055 | Request &1 belongs to DataSource &2. | 
| 056 | Request &1 belongs to system &2 (current system: &3) | 
| 057 | The BW system does not support the import of selections | 
| 058 | Missing authorization for display of table content (S_TABU_DIS) | 
| 059 | Database table &1 is a local object -> long text | 
| 060 | Class &1 does not exist | 
| 061 | Class &1 does not implement interface &2 | 
| 062 | Cannot create an instance for class &1 | 
| 063 | Cannot create a public instance of class &1 | 
| 064 | Constructor of class &1 has mandatory parameters | 
| 100 | ******** Messages for Generic Extraction ************************* | 
| 101 | Function not yet supported | 
| 102 | DataSource already exists | 
| 103 | Functional area does not exist | 
| 104 | Specify a new structure | 
| 105 | Specified structure does not exist | 
| 106 | Not able to maintain DataSource & | 
| 107 | Error &1 in functional module &2 | 
| 108 | InfoSource exists already | 
| 109 | InfoSource not yet created | 
| 110 | Not able to maintain InfoSource & | 
| 111 | Failed to create InfoSource & | 
| 112 | Failed to create DataSource & | 
| 113 | Not able to maintain InfoSource & | 
| 114 | DataSource &1 has been set up for the extraction of &2 | 
| 115 | DataSource & has an invalid type | 
| 116 | DataSource & has been deleted successfully | 
| 117 | Was not able to delete InfoSource & successfully | 
| 118 | Specify the name of the DataSource that you want to create | 
| 119 | Only transaction data can be converted into an InfoSource | 
| 120 | Only transaction data can be converted into a DataSource at this time | 
| 121 | Not possible to handle DataSources for data marts | 
| 122 | Specify the name of the InfoSource that you want to create | 
| 123 | Operation canceled | 
| 124 | Structure already exists | 
| 125 | Extraction structure name is not in the namespace | 
| 126 | 1.2B metadata is no longer supported | 
| 127 | DataSource &1 already exists in content version. Cannot be created | 
| 189 | A DataSource-append must have the extraction method 'A' | 
| 190 | The name of DataSource & is too long to extract deltas | 
| 300 | ********* Messages for Setting Up Deltas for Master Data ********* | 
| 301 | Basic characteristic does not exist | 
| 302 | Error in extract structure for the basic characteristic | 
| 303 | Table & not found in the DDIC | 
| 304 | Internal errors when reading table & from the DDIC | 
| 305 | Entries are incomplete | 
| 306 | Table &2 for change document object &1 does not exist | 
| 307 | Error occurred when saving | 
| 308 | Table &1 for change document object &2 cannot be used | 
| 309 | Invalid InfoObject type | 
| 310 | Delta-update has been set up | 
| 311 | No delta update can be set up for structure & | 
| 312 | Assign fields to the compounded InfoObjects | 
| 400 | InfoSource &1 is not in the customer namespace | 
| 401 | Specify a basic characteristic | 
| 402 | Characteristic has a data element (leave the field blank) | 
| 403 | The specified table & does not exist | 
| 404 | Only transparent tables and database views can be extracted | 
| 405 | The field &1 in extract structure &2 can be in lowercase | 
| 406 | Text are not maintained completely | 
| 407 | InfoSource has not been saved | 
| 408 | Error in the program; inform SAP | 
| 409 | DataSource has been saved successfully | 
| 410 | An InfoObject has to start with 0 or a letter | 
| 411 | Only SAP is permitted to create InfoObjects that start with 0 | 
| 412 | InfoObject name is too long | 
| 413 | InfoObjet name is too short | 
| 414 | Basic character for which you want to activate the delta, does not exist | 
| 415 | Delta can be activated only for master data extracting generically | 
| 416 | Specified extraction type is invalid | 
| 417 | A delta has already been set up | 
| 418 | Set up delta only when extracting using a view | 
| 420 | InfoSource still has assigned InfoObjects | 
| 421 | InfoSource is still being used by transfer structures | 
| 422 | InfoSource & already supports the structure | 
| 423 | Specify an InfoSource | 
| 500 | **** Messages for Standard Master Data Extractors ***** | 
| 501 | Was not able to determine company code or cost center for plant & | 
| 601 | Init not supported. Alternative: RODPS_REPL_TEST |