RMSRCP - RMS-RCP: Messages for IPPE Object RCP

The following messages are stored in message class RMSRCP: RMS-RCP: Messages for IPPE Object RCP.
It is part of development package CPPERCP in software component PLM-RM. This development package consists of objects that can be grouped under "RMS-RCP: iPPE Objects for Appl. Type RCP (Recipe, Header)".
Message Nr
Message Text
000Error executing function module &1: exception &2
001Change status creation is not permitted; later change status is closed
002First close the processing of all preceding change statuses
003First close the processing of all preceding change statuses
004Rejection is not permitted; later change status is closed
005First close the processing of all preceding change statuses
006Object type missing from table 'tcc01': &1
007RMS 1.0 not implemented on system
008Restart the XPRA after error has been corrected
009Date shift is not possible; recipe date before current date not permitted
010Date shift is not possible; recipe date cannot be changed
011Date shift is not possible; Recipe &1 is already being processed
012Choose a date after the start of the preceding change status in recipe &
013Choose date before the start of the succeeding change status in recipe &1
014Date shift is not permitted; See status of recipe &1
015Change number &1 is not used in the recipe header
016Data inconsistency in recipe; contact your technical support
017Change state for change no. &1 cannot be edited; recipe is displayed
018Change number &1 is currently being processed
019Program ended
020Select an entry first
021Position the cursor in the column you want to sort
022No change numbers require updating
023You do not have &1 rights for recipe &2
024Cannot create relationship between &1 and &2
025Error saving the relationships
026Cannot create specification type for node type &1
027Program ended with errors
028Runtime &1: &2 [ms]
029Cannot read Customizing entry for recipe type &1
030Recipe deletion is not permitted; see recipe status
031Error while deleting documents; contact your technical support
032Error while deleting texts; contact your technical support
033Error deleting the scope of application; contact your technical support
034Hierarchy relation already exists
035Change statuses are not allowed for recipes with versioning
036Cannot delete existing recipe relationships
037The date you entered is in the past
038A relationship with a higher-level recipe already exists
039Enter either wildcards or a range for the search function
040Function is not possible; Customizing for recipe type & is incomplete
041RMS 2.0 is not implemented on the system
042Enter the material
043Enter the plant
044Unable to read data for recipe type
045Cannot retrieve EH&S key for recipe &1
046Cannot delete relationship; relationship was not found
047Relationship already exists
050&1 is not permitted; object category is not defined for recipe view
051Assignment is not permitted; only one higher-level recipe is allowed
052Changes to structure and hierarchy affect all change statuses
053Deletion is not possible; formula is recipe-dependent
054You cannot change the assignment; formula is recipe-dependent
055Changing the structure is not permitted; see recipe status
056Recipe status does not allow changes to the data
057Short texts or long texts already exist for this equipment requirement
060Recipe &3 &4: Valid-to date &1 is before valid-from date &2
061Choose a higher value for the maximum lot size than for the minimum
062WBS element &1 does not exist
063Specify the lot size for recipe &1 &2
064Specify the plant for recipe &1 &2
065Specify the unit of the lot size for recipe &1 &2
066Valid-from date does not match the change number date
067Enter the object category for the person responsible for recipe &1 &2
068Specify the person responsible for recipe &1 &2
069Enter a valid object category to find persons responsible
070Enter the valid-from date of the new change status as the key date
071Error while generating change number &1; contact your technical support
072No change status for the recipe exists for change number &1
073Function is not possible; recipe is not valid before &1
074Person responsible &1 does not exist for object type &2
075Creation not permitted; change status for valid-from date already exists
076Use a key date or valid-from date from today's date onwards
077Specify the authorization group
078Specify the reference language
079Change status &1 was loaded
080Change status is outside the valid range
081Authorization group &1 does not exist
082Error while converting date; contact your technical support
083Enter a key date or a change number
084The recipe you entered does not exist
085Date is before the valid-from date of the recipe
086Change number &1 does not exist
087No change status for change no.; recipe is loaded at date of change no.
088No change status exists for the change no.; recipe is loaded for key date
089Authorization group &1 is not assigned to specification category &2
090Recipe to be copied does not exist
091A recipe with the name you entered already exists
092Enter the key date or change number of the recipe to be copied
093Enter a key date or a change number for the new recipe
094Recipe to be copied does not exist
095No change status found for the change no. entered in recipe to be copied
096Change number &1 does not exist
097Complete or delete the data for the recipe to be copied
100Change documents about status changes do not exist
101Enter the recipe name
105Formula &1 is not the last stage formula of recipe &2
110Create recipes of this type with a change number
111Create recipes of this type without a change number
112Assign an independent formula to the recipe
113Assignment is not possible; recipe with dependent formula
116Plant &1 does not exist
117You are not authorized to assign class &1
118A building block with this name already exists
120You are not authorized to display the scope of application
125You are not allowed to delete the recipe
130Select one recipe only for deletion in the navigation tree
131You may only delete one recipe
150Status object does not exist; contact your technical support
151Function is not possible; recipe without user status profile
152Inconsistency in status management; contact your technical support
153Operation &1 is not allowed
200Error while initializing the classification system
250Recipe &1 already exists in the target system
251Recipe &1 does not exist in the target system
252No. of change statuses in target system is higher than in source system
253Change status &1 already exists in the target system
254Change status &1 does not exist in the target system
255Text &1 already exists in the target system
256Text &1 does not exist in the target system
257Relationship &1 already exists in the target system
258Relationship &1 does not exist in the target system
259Unable to create relationship; &1 does not exist in the target system
260Cannot open application log
261System could not determine destination
262Internal error reading change pointer(s)
263No data to be replicated found
264Error while creating IDoc
265Cannot transfer recipe &1 &2 &3
266Recipe &1 &2 &3 was transferred
267No general recipe data available for processing
268Error linking the grid control
269Document assignment &1 already exists in the target system
270Document assignment &1 does not exist in the target system
271Unable to delete superfluous document assignment (&1)
272Unable to assign document (&1)
273Cannot create recipe &1
274Unable to create change status &1 &2
275Unable to change the status of change status &1 &2
276Unable to delete superfluous text (&1)
277Unable to save text (&1)
278Internal error initializing object dependencies
279You are not authorized to edit this recipe
280Invalid node type while editing the general recipe
281Unable to save document assignments
282Unable to delete superfluous relationship in the target system (&1 to &2)
283Unable to create relationship (&1 to &2)
284Recipe &1 exists under recipe (GUID) &2 in the target system
285Recipe &1 to be edited does not contain a GUID
286Change status &1 (recipe &2) to be processed does not contain a GUID
287Recipe &1 cannot be deleted in the target system
288Unable to delete superfluous scopes of application (&1)
289Scope of application &1 does not exist in the target system
290Scope of application &1 already exists in the target system
291Unable to create scope of application (&1) in the target system
292Unable to determine scope of application for change status &
293Invalid format for lot size in change status &1 &2
294Unable to assign change status &1 &2 to a general recipe
295Errors in transfer structures; general recipes cannot be replicated
296Change number &1 does not contain the required object types
297Conversion of unit of measurement for general recipe &1 &2 failed
298Unable to assign text lines for change status &1 &2 to a change status
299Unable to assign relationship to general recipe &1 to a general recipe
300Translation of language for text &1 &2 failed
301Unable to assign document assignment for change status &1 &2
302Unable to assign scope of application for change status &1 &2
303Error distributing recipes
304Unable to assign change status &1 &2 to a general recipe
305Unit of measurement for lot size is missing in change status &1 &2
306Unable to assign text lines for change status &1 &2 to a change status
307Unable to perform document assignment for change status &1 &2
308Unable to assign relationship to general recipe &1 to a general recipe
309Unable to assign scope of application for change status &1 &2
310You are not authorized to read this recipe
311No site recipe data available for processing
312Errors occurred
313You are not authorized to edit this recipe
314Project &1 does not exist
315Existing change status must have a valid-from date
316Specify a valid-from date for the recipe
317You are not authorized to edit this stage
318You are not authorized to edit this operation
319You are not authorized to edit this action
320You are not authorized to edit this equipment requirement
321You are not authorized to read this stage
322You are not authorized to read this operation
323You are not authorized to read this action
324You are not authorized to read this equipment requirement
325You are not authorized to edit this process
326You are not authorized to read this process
327Error creating a dependent formula
328Relationships are not allowed between the same recipe types
330No authorization to & recipe & with authorization group &
331No authorization to & recipe & with specification category &
332No authorization to & recipe & with object category &
333No authorization to & recipe & with responsibility &
334No authorization to & recipe & with confidential &
335No authorization to & recipe & with project role &
336No authorization to & recipe & with status &
337No authorization to & recipe due to scope of application
338No authorization to &1 recipe
339No authorization to create recipe with specification category &
340Migration status of process parameters is not permitted
341Change status &1 cannot be set consistently
342Consistency of change status &1 cannot be reset
343Generated production versions cannot be deleted
344Recipe is blocked by migration; you can only display it
345No authorization to set the status &1 in recipe &2
Privacy Policy