RMXTPP - TMS-PP: Messages for PP Component

The following messages are stored in message class RMXTPP: TMS-PP: Messages for PP Component.
It is part of development package RMXTPP in software component PLM-RM. This development package consists of objects that can be grouped under "Main Package - Trial: PP-PI Integration".
Message Nr
Message Text
000**************************** Trial Planning *****************************
001Planning was not started
002Plant &1 does not exist
003Planned order data is incomplete
004Trial type &1 is not assigned a transformation group
005Trial &1 is not assigned a planned order
007No master recipe is assigned to the trial
008Planned order &2 is assigned to trial &1
009Date &1 is not within the planning period
010No process order is assigned to the trial &1
011Process order &2 is assigned to trial &1
012Trial &1 does not have a lower-level trial
013Planning level for trial &1 is not unique
014No planned orders are defined for the type of trial &1
015No planned order created for trial &1
016Trial &1 and the lower-level trial &2 are inconsistent
017Data is incomplete for the explosion of trial &1
018Planned orders are not permitted for trial type &1
019Planning for trial &1 was not exploded completely
020Planning for trial &1 was exploded completely
021Error while checking the planned orders for trial &1
022Planned order &1 for trial &2 was deleted
023No recipe is assigned to trial &1
024Master recipe &2 from recipe group &3 is assigned to trial &1
025PP control parameters are not available for plant &1
026Create the planned order profile and order type
027No PP-PI objects are assigned to trial &1
028No generated PP-PI objects are assigned to trial &1
029Production version &1 for material &2 in trial &3 was deleted
030Background process could not be started
031No task from class &1 exists in the current task group &2
032Process orders are not permitted for trial type &1
033Process orders are permitted for the lowest hierarchy level only
034No process order created for trial &1
035No recipe transformation is carried out for trial &1
036Generation of process orders is incomplete for trial &1
037Generation of process orders is complete for trial &1
038Background job for trial &1 was deleted
039Background job for trial &1 was not released
040Task &1 started for trial &2
041Trial &1 is planned
042Task &1 for trial &2 ended with errors
043Task &1 for trial &2 ended without errors
044Status &1 (&2) was set
045Status &1 (&2) was not set
046Status &1 (&2) was reset
047Status &1 (&2) was not reset
048Trial &1 does not have status &2 (&3)
049Background jobs are not available for trial &1
050Error during the selection of background jobs
051Some background jobs for trial &1 are not finished
052Resource &1 is not considered in the current planning
053Internal error while displaying background jobs
054Trial &1 is being processed in the background
055PP control parameters are not available for plant &1, trial type &2
056Planned date is not available for trial &1
057Trial-type-independent PP control parameters not available for plant &1
058Internal error while selecting the trial data
059PP control parameters are not available for plant &1
060&1 is not a workday in plant &2; forward sched. used for production start
061Choose a trial
062Save the data
063Error during processing; see application log
064Delimitation of planning period is incomplete
065Master recipe &1, recipe group &2 of trial &3 was deleted
066Trial &1 is assigned BOM alternative &2 for material &3
067Trial &1 is assigned production version &2
068PP-PI objects are still assigned to the trial &1
069Delete operation was ended manually
070Delete operation is not completed
071Delete operation is completed
072Production version &1 for material &2 of trial &3 was not deleted
073Master recipe &1, recipe group &2 of trial &3 was not deleted
074Master recipe &1, recipe group &2 of trial &3 was deleted
075BOM alternative &1, application &2 of trial &3 was not deleted
076BOM alternative &1, application &2 of trial &3 was deleted
077No production versions deleted
078No master recipes deleted
079No BOMs deleted
080Process order &1 of the trial &2 was deleted
081Process order &1 of the trial &2 was not deleted
082Data was saved
083Changes to the object have not been updated yet
084Planned date must not be deleted
085Task cannot be executed in a different logical system
086Planned date &1 is in the past
087Select a valid resource
088Material availability is no longer checked
089Error when saving data
090Finished prod. for plnd order is not the same as finished prod. for trial
091Plant for planned order is not the same as plant for trial
092Quantity for planned order is not the same as quantity for trial
093Trial is not planned; planned dates for trial/planned order do not match
094Trial &1 is not assigned a planning resource
095Unable to explode a BOM
096Planned order &1 has a production version; master recipe not deleted
097Data was saved
098At least one resource does not match PP control parameters in plant &1
099At least one resource is not assigned to plant &1
100**************************** Process Order *****************************
101Selection cannot be restricted to operation/phase/material
102Choose one operation/phase or one produced intra material
103Choose only one operation or phase or only produced intra material
104Selected operation/phase is not valid
105Selected material is not valid
106Selected material is not a produced intra material
107Selected operation does not have a produced intra material
108In display mode, only material qty calculation is possible, no selection
109Quantities were adjusted; adjust the intra material ingredients manually
110No relevant items found
111Quantities were adjusted
112Error while reading the class/characteristics
113Error while reading the status information for the order
114Error while updating the inspection lot table
115Error while determining the stream assignments
116Process order is not assigned to a trial; function not possible
117Internal Error
118No classification was created for at least one batch
130************************** PI Sheet *************************************
131Error while sending the message to the trial
132Process order is not assigned to a trial; cannot be sent
133Error while reading the process assignments
134Error while accessing the trial
135Error while accessing the PP control parameters
136No quantity is assigned to the stream; cannot be sent
137No role or quantity is assigned to the stream; cannot be sent
138Error while reading the process and stream assignments
139Message does not contain the sequence number of the process parameter
140Message does not contain value assignment type of the process parameter
141Assign results to the trial correctly
142Plant and process parameter class must be copied
143Error while transferring the result to the trial
144Cannot determine a role for the stream
145PI sheet is not completed; cannot get results
146PI sheet does not exist for the process order
147No process order is assigned to the trial
148Error while accessing PI sheet
149No process messages found
150No suitable reservation found; role set to 'Input'
151Error while reading order data; role set to '2nd Output'
152Error when reading the order data
200******************************** Print ********************************
201Printing was canceled
202Printing was canceled because the process order is not released
203Error during printing
204Printing was successful
300---------- XML Container PP Trial Results -----------------
301No data available for object &1
Privacy Policy