RPLM_QIMT -
The following messages are stored in message class RPLM_QIMT: .
It is part of development package RPLM_QIMT_BE in software component EP-PCT-MAN-MT. This development package consists of objects that can be grouped under "Quality Inspector & Maintenance Technician BE".
It is part of development package RPLM_QIMT_BE in software component EP-PCT-MAN-MT. This development package consists of objects that can be grouped under "Quality Inspector & Maintenance Technician BE".
Message Nr ▲ | Message Text |
|---|---|
| 001 | Error during transfer of parameter &1 |
| 002 | Error while reading documents in class &1 |
| 003 | No originals exist |
| 004 | Storage category cannot be read |
| 005 | Insufficient authorization |
| 006 | An error occured in parser class &1 |
| 007 | Loading the originals causes an error in class &1 |
| 008 | Problems arose when calling the BAdI in class &1 |
| 009 | A conversion problem arose in class &1 |
| 010 | &1: Internal error &2 |
| 011 | Error accessing & |
| 012 | Long text for the inspection method cannot be read in class &1 |
| 013 | No status profile exists |
| 014 | Problems arose when reading the status |
| 015 | Document of type &3 created for object &1 &2 |
| 016 | Document of type &3 could not be created for object &1 &2 |
| 017 | Document of type &3 for object &1 &2 was deleted |
| 018 | Document of type &3 for object &1 &2 could not be deleted |
| 019 | Problems arose when setting the user status in class &1 |
| 020 | The equipment is not installed |
| 021 | Specify an installation location for the equipment |
| 022 | Error reading the personalization data |
| 023 | Equipment was installed successfully |
| 024 | Equipment was successfully replaced |
| 025 | Equipment was successfully dismantled |
| 026 | Value &1 to &2 of &3 |
| 031 | Select one line only |
| 032 | No objects found for search criteria |
| 033 | Input required for no. of days in the future and no. of days in the past |
| 034 | Input required for no. of days in the past and no. of days in the future |
| 035 | Selection criterion "Partner" contains invalid characters |
| 036 | Long text for object &1 does not exist |
| 037 | MIMETYPE &1 is not available in your Customizing |
| 038 | Multiple selection is not possible |
| 039 | Counter reading difference calculated for measuring point &1 |
| 040 | Counter reading calculated for measuring point &1 |
| 041 | No personalization data found |
| 042 | Measurement document already created for measuring point &1 |
| 044 | The selected files have been deleted |
| 045 | Enter a counter reading/counter reading difference for measuring point & |
| 046 | Counter reading for point & must be lower than counter overflow reading |
| 047 | Counter reading for point &3 in doc. &1 higher than in subsequent doc. &2 |
| 048 | Counter reading for measuring point &2 lower than in previous document &1 |
| 049 | Counter reading for measuring point &2 higher than in prev. document &1 |
| 050 | Counter reading for measuring point & must be a positive value (or zero) |
| 051 | The counter reading entered will lead to a counter overflow for point & |
| 052 | Counter reading difference for measuring point & must be a positive value |
| 054 | Order &1 saved |
| 055 | Order &1 saved with notification &2 |
| 056 | Planning plant for equipment &1 is different |
| 057 | Planning plant for functional location &1 is different |
| 060 | Fill in all the required fields |
| 061 | Select equipment or functional location only |
| 062 | Notification/order or AER cannot be created |
| 063 | Notification/order or AER for assembly/material cannot be created |
| 064 | Equipment was changed |
| 069 | Files of type &1 are only allowed for document type &2 &3 |