RSQU - S-API ab 4.0: Deltaqueue, Realtime Update
The following messages are stored in message class RSQU: S-API ab 4.0: Deltaqueue, Realtime Update.
It is part of development package RSU2 in software component BC-BW. This development package consists of objects that can be grouped under "Delta Queue of Service APIs (from 4.0B)".
It is part of development package RSU2 in software component BC-BW. This development package consists of objects that can be grouped under "Delta Queue of Service APIs (from 4.0B)".
Message Nr ▲ | Message Text |
|---|---|
| 000 | Internal error occurred |
| 001 | ************* Message for the central delta ********************** |
| 002 | Client & does not exist in the source system |
| 003 | The delta queue entries could not be deleted |
| 004 | The delta queue could not be read |
| 005 | There are no transfer rules for the DataSource |
| 006 | No parameters exist yet for the delta transfer |
| 007 | The queue is empty |
| 008 | DataSource & does not support delta update |
| 009 | Queue & does not exist in the source system |
| 010 | There are still no BW systems connected to DataSource &1 |
| 011 | You cannot repeat the last delta selection |
| 012 | Invalid selection options |
| 013 | Errors writing to table & |
| 014 | The extraction structure &1 of DS &2 is a view. This allows no CustApp |
| 015 | The queue management metadata could not be deleted |
| 016 | There is a discrepancy between the confirmation and deletion of qRFC-LUWs |
| 017 | The selection for the field &1 has still not been initialized |
| 018 | Delta has not been set in delta queue |
| 019 | Data still in delta queue - no init possible |
| 020 | Some of the initialization requirements have not been completed |
| 021 | Name & is too long to be used in the delta update |
| 022 | Queue management in BW cannot be deleted |
| 023 | A consistent delta extraction is not possible |
| 024 | Could not determine BW release of logical system '&1' |
| 025 | DDic structure & does not exist or is not active |
| 026 | &1, version &2: Could not create DDic structure &3 |
| 027 | Cannot read queue data (DataSource &1, Version &2) |
| 028 | NAMETAB entry for structure & is not up-to-date |
| 029 | Update mode for extractor has been changed to "Repeat" |
| 030 | Structure &1 of DataSource &2 has been repaired |
| 031 | Error when reading from the qRFC queue: QSTATE = &1 |
| 032 | The IDoc does not have the correct format (mode C, type RSRQST) |
| 033 | Request number & does not exist in this system |
| 034 | DataSource & supports no delta init simulation |
| 035 | Request & is not an init request |
| 036 | &1 LUWs confirmed and &2 LUWs to be deleted with function module &3 |
| 037 | Altogether, &1 records were filtered out through selection conditions |
| 038 | Only enter numbers in the customer number field |
| 039 | End of the TID selections |
| 040 | & TIDs selected |
| 041 | Failed to write data in delta queue |
| 042 | Delta extraction limited to &1 data packages |
| 050 | Deletion started, BW exit queue &1, destination &2, QCOUNT &3..&4 |
| 051 | The LUW with transaction ID (TID) &3 could not be deleted |
| 052 | &1 &2 |
| 053 | Deletion complete, &3 LUWs were deleted |
| 060 | Synchronization: Delta does not exist (DataSource &1, target system &2) |
| 061 | Synchronization: No new delta request (DataSource &1, target system &2) |
| 062 | Synchronization: Delta initialization &3 for system &2 not found |
| 063 | Synchronization: Selection for delta initialization &3 is different |
| 064 | Synchronization: Delta initialization for system &2 is inconsistent |
| 100 | Invalid system state |
| 101 | Deviation of &1 seconds between qRFC counter &2 and current time &3 &4 |
| 102 | Cannot transform time stamp &1 to qRFC counter (rc = &2) |
| 200 | *** Process Chains *** |
| 300 | ********** Messages on Close to Realtime Update |
| 301 | Realtime extr. started: DataSource &1, target system &2 |
| 302 | Realtime extraction succesfully finished: DataSource &1, target system &2 |
| 303 | Realtime extr. ended with errors: DataSource &1, target system &2 |
| 304 | Realtime confirmation of LUWs started DataSource &1, target system &2 |
| 305 | Real-time conf. of LUWs ended success. DataSource &1, target system &2 |
| 306 | Real-time conf. of LUWs ended with errors DataSource &1, target system &2 |
| 307 | & LUWs were set to READ status |
| 308 | & LUWs were read |
| 309 | Real-time deletion of LUWs started DataSource &1, target system &2 |
| 310 | Real-time deletion of LUWs finished with errors |
| 311 | Real-time deletion of LUWs finished successfully |
| 312 | Real time: Error while calling the delta extractor |
| 899 | Data created successfully |