Message Nr ▲ | Message Text |
---|---|
000 | PSA metadata is inconsistent |
001 | PSA table &1 does not exist |
002 | PSA table &1 is not partitioned |
003 | Error determining partition data of PSA table &1 |
005 | &1 is being extracted with DTP request &2. No more maintenance possible. |
006 | &1 has been extracted with DTP request &2. No more maintenance possible. |
008 | Request &1 not found in metadata of PSA &2 |
010 | PSA-table cannot be extended because there is no extended storage |
011 | Extension status of PSA-table &1 unchanged. Conversion required. |
012 | Extension status of PSA table &1 unchanged. Conversion required. |
015 | Could not find PSA table &1. |
016 | Conversion is not possible because extended storage is unavailable. |
017 | Extended storage error. |
018 | SQL error when trying to determine DB type for table &1. |
019 | Could not determine DB type of table &1. |
020 | Table &1 cannot be converted because it is of DB type &2. |
021 | Conversion of table &1 refused due to inconsistent status. |
022 | Table &1 cannot be converted because it is of PSA type &2. |
023 | Table &1 cannot be locked for conversion. |
024 | Could not lock DataSource &1 (&2) |
025 | Extended table flag cannot be changed because a conversion is running |
026 | DataSource &1 (&2) not found |
027 | Could not lock DataStore object &1 |
028 | DataStore object &1 not found |
029 | Could not rename table because table &1 already exists |
030 | Error while trying to rename table &1 as &2. Return code &3. |
031 | Error while dropping table &1. Return code &2. |
032 | Could not activate DataStore object &1 |
033 | Could not activate DataSource &1 (&2) |
034 | Table &1 created by a different process |
035 | New data was inserted into table &1 while conversion was running |
036 | PSA metadata inconsistent for PSA table &1 and request &2 |
037 | DB_STORAGE_GET for table &1 failed with return code &2 |
038 | DB_STORAGE_PUT for table &1 failed with return code &2 |
039 | DDIF_TABL_ACTIVATE for table &1 failed with return code &2 |
040 | RSDU_PSA_PART_INSTANTIATE for table &1 failed with return code &2 |
041 | New version &2 of PSA &1 found while conversion was running |
042 | Conversion of empty old versions of DataSources not supported |
043 | Cannot change conversion direction again |
044 | Table &1 deleted by a different process |
045 | PSA data inconsistent for PSA table &1 and request &2 |
046 | Cannot reverse conversion as conversion is almost finished (PSA table &1) |
047 | Error while checking if table &1 exists |
048 | SQL exception |
049 | Could not change hash partitioning for table &1 |
050 | Conversion of table &1 (write-optimized DataStore object &2) started |
051 | Conversion of table &1 (DataSource &2 (&3)) started |
052 | Conversion of table &1 (old version &3 of DataSource &2) started |
053 | Direction: &1; status: &2 |
054 | Table renamed from &1 to &2. New status is &3. |
055 | Data completely copied. New status is &1. |
056 | Table &1 dropped. New status is &2. |
057 | Conversion finished |
058 | Extended table flag has been changed while conversion was running |
059 | Original partition numbers in metadata restored |
060 | Reverse conversion of table &1 (old version &3 of DataSource &2) started |
061 | Write-optimized DataStore object &1 activated. New status is &2. |
062 | DataSource &1 (&2) activated. New status is &3. |
063 | Table &1 (old version of DataSource) restored. New status is &2. |
064 | Access blocked because PSA &1 (version &2) is being converted |
065 | Table &1: Large objects are not supported in extended storage. |
066 | Reverse conversion of table &1 (write-optimized DSO &2) started |
067 | Reverse conversion of table &1 (DataSource &2 (&3)) started |
068 | Conversion not allowed; reverse conversion almost finished (PSA table &1) |
069 | &1 records copied |
070 | DDIF_TABL_GET for table &1 failed with return code &2 |
071 | DDIF_TABL_PUT for table &1 failed with return code &2 |
072 | RSDU_PARTITIONS_INFO_GET for table &1 failed with return code &2 |
073 | Inconsistent storage parameter for table &1 |
074 | Table &1 is not a DataSource |
075 | Table &1 is not an old version of a DataSource |
076 | Table &1 is not the latest version of DataSource |
077 | Table &1 is not a write-optimized DataStore object |
078 | Duplicate records in RSTSODS for table &1 |
079 | Conversion of DataSource &1 (&2) refused because of altered M version |
080 | Conversion of DataStore object &1 refused because of altered M version |
081 | Could not change metadata; method: &1, returncode: &2 |
082 | Metadata (checkbox "extended table") changed |
083 | Error saving error messages |
084 | Unexpected attribute: EXTTABL = &1 |
085 | Conversion report is obsolete due to technology change |