SAP_VF -
The following messages are stored in message class SAP_VF: .
It is part of development package PME_VC_EDITION in software component LO-VC. This development package consists of objects that can be grouped under "Product Modelling Environment - Variant Configuration".
It is part of development package PME_VC_EDITION in software component LO-VC. This development package consists of objects that can be grouped under "Product Modelling Environment - Variant Configuration".
Message Nr ▲ | Message Text |
|---|---|
| 000 | & & & & |
| 001 | Characteristic & already exists in the system |
| 002 | Variant function & already exists in the system |
| 003 | Pre-tests passed successfully |
| 004 | Characteristics created successfully |
| 005 | Variant functions created successfully |
| 018 | An error occured in function & |
| 019 | Parameter & passed to the function with value & |
| 020 | Function & cannot be called in conditional syntax |
| 021 | Function & needs to be called as a pfunction |
| 022 | Value & is invalid for & |
| 023 | Mandatory parameter & must be passed exactly once |
| 024 | Parameter & is passed as an output but should be passed as an input |
| 025 | Parameter & is passed as an input but should be passed as an output |
| 026 | Parameter & is unknown |
| 027 | Value & for & cannot be interpreted as a numeric |
| 028 | Substring offset & and length & is longer than base string length & |
| 029 | Unable to read values of characteristic & |
| 030 | Substring length & is longer than base string length & |
| 031 | Overflow error when converting number & |
| 032 | Parameter & must not be passed more than once |
| 033 | Only one of these parameters can be used at the same time & & & & |
| 034 | One of parameters & & & & must be passed to the function |
| 040 | Value & is invalid for &. Use '0' to '9' or 'S' |
| 041 | Value & is invalid for &. Use one of ',' '.' ',.' '.,' 'S,' 'S.' |
| 042 | Value & is invalid for & NEGATIVE. Use one of '-L' '-R' '-()' '-ABS' |
| 043 | Value & is invalid for &. Use '-' for NEGATIVE |
| 044 | Value & is invalid for &. Use '0' to '9' |
| 045 | Value & is invalid for &. Use a positive number |
| 046 | Value & is invalid for &. No options are currently supported |
| 047 | Value & is invalid for & NEGATIVE. Use '-ABS' |
| 048 | Value & is invalid for & MINIMUM. Use MIN {0} where {0} is a numeric |
| 049 | Value & is invalid for & MAXIMUM. Use MAX {0} where {0} is a numeric |
| 050 | Value & is invalid for &. Use 'MIN' for MINIMUM or MAX for MAXIMUM |
| 051 | Value & is invalid for & EXIT. Use 'EXIT' |
| 052 | Value & is invalid for & DELLEADING. Use 'DELETELEADING {0}' w. any char |
| 053 | Value & is invalid for &. Use EXIT, DELETELEADING, SEPARATOR or PLACES |
| 054 | Cstic & is of type &. Parameter & should be passed |
| 055 | Value & is invalid for &. Use one of CO, CN, CA, NA, CS, NS, CP, NP |
| 056 | Value & is invalid for & INST. Use INST {SELF|PARENT|ROOT} |
| 057 | Value & is invalid for &. Use 'INST' for INSTANCE |