SZDM_CC_CHKS_TITLES - Title messages related to check classes

The following messages are stored in message class SZDM_CC_CHKS_TITLES: Title messages related to check classes.
It is part of development package SZDM_CC_CHECKS in software component BC-UPG-DTM-TLA. This development package consists of objects that can be grouped under "Package for actual check classes of ZDM CC".
Message Nr
Message Text
000&1&2&3&4
001Static table classification expected, but not found
008XPRA cannot be deployed with Upgrade using Zero Downtime Option
009Objects of this type cannot be deployed with an upgrade using ZDO
010Objects of this type cannot be deployed with an upgrade using ZDO
011TABU cannot be deployed with Upgrade using Zero Downtime Option
012SL-API does not comply with rules for Upgrades using Zero Downtime Option
013AIM cannot be executed during Upgrade using Zero Downtime Option
014TABL/TABD cannot be deployed with Upgrade using Zero Downtime Option
015DOMA/DOMD cannot be deployed with Upgrade using Zero Downtime Option
016DTEL/DTED cannot be deployed with Upgrade using Zero Downtime Option
017Object of this type is inconsistent for an upgrade using ZDO
018Switch BADI impl. is not compliant to Zero Downtime Option (ZDO) rules
019Objects of this type cannot be deployed with an upgrade using ZDO
039Lock mode conflicts with static table classification
043An after-import method is not ZDO-enabled
044An API to be used by after-import methods is not ZDO-enabled
045An XPRA is not ZDO-enabled
047A Switch-BADI implementation is not ZDO-enabled
049Inconsistent metadata for configuration task
050Inconsistent after-import method metadata
051Inconsistent SL API metadata
052Inconsistent XPRA report metadata
053Inconsistent Switch-BADI implementation metadata
054An API to be used by after-import methods is not ZDO-enabled
055An XPRA is not ZDO-enabled
056A Switch-BADI implementation is not ZDO-enabled
057ZDO enablement required for configuration task
070Objects of this type should not be deployed with an upgrade using ZDO
071The table will be read only during an upgrade using ZDO
072Table needed for After Import Method cannot be made read only
073Table needed for XPRA execution cannot be made read only
074Table needed for Switch Badi execution cannot be made read only
075Table accessed by an API used by AIMs cannot be made read only
076Table defined for Switch Badi cannot be made read only
077Tables referencing this object become read only during a ZDO upgrade
120An After Import Method uses RFC-calls
121An XPRA report uses RFC-calls
122A Configuration-Task uses RFC-calls
125An After Import Method accessed a table with Native-SQL
126An XPRA report accessed a table with Native-SQL
127A Configuration-Task accessed a table with Native-SQL
130An After Import Method performed a non-declared read-access to a table
131An XPRA report performed a non-declared read-access to a table
132A Configuration-Task performed a non-declared read-access to a table
135An After Import Method performed a non-declared write-access to a table
136An XPRA report performed a non-declared write-access to a table
137A Configuration-Task performed a non-declared write-access to a table
404RFC connection to GTADIR server is not possible
898Exception occurred (see details). If reoccur. create incid:BC-UPG-DTM-TLA
899dummy
Privacy Policy