S_ARC_TRANS - Transfer von Archivadministrationsdaten (Systemstilllegung)

The following messages are stored in message class S_ARC_TRANS: Transfer von Archivadministrationsdaten (Systemstilllegung).
It is part of development package S_ILM_ARC_TRANS in software component BC-ILM-ACA. This development package consists of objects that can be grouped under "Transfer Archive Administration (System Shutdown)".
Message Nr
Message Text
001Job could not be scheduled for &2
002Job could not be released for &4
003Job scheduled for &1
004Jobs could not be scheduled periodically for &1
005Select at least one entry
006You are not authorized to access the file &1
007File &1 cannot be closed
008Transfer of data to &1 started
009Data transferred for run &1: New run &2
010Data transfer for run &1 tested successfully
011Data transfer completed with errors
012Data transfer completed successfully
013Error while transferring the contents of the file &1
014Error while transferring data for run &1
015Contents of the file &1 transferred successfully
016Transfer of the contents of the file &1 tested successfully
017Error while adding the data for run &2 to the table &1
018Variant &1 saved as default for user &2
019You are not authorized to display runs for archiving object &1
020You are not authorized to change runs for archiving object &1
021Archiving object &1 does not exist in the current RW system
022All available file names are already being used
023No jobs available for this selection
024Error during insertion of the attachment into table &1
025Error during data transfer for &1 &2 &3 &4
026Select a document type (attachments or print lists)
027&1 attachments added (for &2)
028&1 print lists added (for &2)
029Attachment with ID &1 added (for &2)
030Print list with ID &1 added (for &2)
031Error during transfer of attachment ID &1 (for &2)
032Error during transfer of print list ID &1 (for &2)
033&1 references (attachments) set (for &2)
034&1 references (print lists) set (for &2)
035Setting of references in &1 started
036&1 attachments added again (for &2)
037&1 print lists added again (for &2)
038Attachment with ID &1 added again (for &2)
039Print list with ID &1 added again (for &2)
040Setting of references successfully completed
041Setting of references ended with errors
042&1 references (attachments) updated (for &2)
043&1 references (print lists) updated (for &2)
044Reference for Attachment with ID &1 Set (for &2)
045Reference for print list with ID &1 set (for &2)
046Reference for attachment with ID &1 updated (for &2)
047Reference for print list with ID &1 updated (for &2)
048Error during setting of the reference of attachment ID &1 (for &2)
049Error during setting of the reference of the print list ID &1 (for &2)
050Transfer of content repository definitions in &1 started
051Transfer of content repository definitions ended with errors
052Transfer of content repository definitions successfully completed
053Content repository definitions for CREP &1 added
054Content repository definition for CREP &1 updated
055Enter either a destination or system ID and client
056No destination is entered for system &1 and client &2
057Job for file conversion could not be started
058Job for filling the repository could not be started
059Cannot start job for adjustment of settings
060No distribution available, select the Create Distribution button
061Only choose one entry
062New logical path is required. Option "Transfer File Content" is selected.
063Administration data for archive file &1 could not be transferred.
101Dimenion with dimension key &1 inserted
102ISO code &1 was inserted
103Unit of measure &1 has been inserted
104Language-dependent entry for unit of measure &1 inserted (language &2)
105Different definition of unit of measure &1
106Different definition of language-dependent entry for unit of measure &1
107Synchronization of units of measure started in &1
108Archiving run &1 is being read
109Dimension with dimension key &1 cannot be inserted
110Measurement unit &1 cannot be inserted
111No sessions for archiving object &1 or &2
112Archiving session &1 does not exist
113Archiving session &1 did not originate in system &2
114Archiving session &1 does not belong to archiving object &2 or &3
115Archiving session &1 did not originate in client of origin &2
116No archiving files exist for archiving session &1
117Synchronization of measurement units with errors is complete
118Archiving session &1 does not contain table &2
119Error while inserting ISO code &1
120Error while inserting dimension &1
121Error while inserting measurement unit &1
122Error while insterting language-dependent entry for measurement unit &1
123Currency &1 inserted
124Error while inserting currency &1
125Different definition for currency &1
126Language-dependent entry for currency &1 inserted (language &2)
127Error while inserting language-dependent entry for currency &1
128Different definition for language-dependent entry for currency &1
129Exchange rate type &1 inserted
130Error while inserting exchange rate type &1
131Different definition for exchange rate type &1
132Language-dependent entry for exchange rate type &1 inserted (language &2)
133Error while inserting language-dependent entry for exchange rate type &1
134Different definition for language-dependent entry for exch. rate type &1
135Number of decimal points added for currency &1
136Error when adding or changing number of decimal points for currency &1
137Number of decimal points for currency &1 changed
Privacy Policy