UPC - Planung: Allgemeine Fehlermeldungen
The following messages are stored in message class UPC: Planung: Allgemeine Fehlermeldungen.
It is part of development package UPC in software component BW-PLA-BPS. This development package consists of objects that can be grouped under "SEM-BPS: General Functions".
It is part of development package UPC in software component BW-PLA-BPS. This development package consists of objects that can be grouped under "SEM-BPS: General Functions".
Message Nr ▲ | Message Text |
---|---|
000 | ********** General messages *************************************** |
001 | You may not have more than 3 field selection boxes together |
002 | Select line |
003 | Value &1 is not permitted for characteristic &2 |
004 | Upper limit must be higher than lower limit |
005 | Characteristic &1 does not exist in planning area &2 |
006 | No input help is available for characteristic &1 |
007 | Objects whose name begins with a number are in the SAP name range |
008 | The name of the object may only contain letters and figures |
009 | Data saved |
010 | Data was deleted |
011 | The name of the object may not begin with the number 0 |
012 | The values were adapted |
013 | Conditions adjusted |
014 | Check the formula for errors |
015 | Term &1 was not found in search area |
016 | Select valid field |
017 | Not all fields are displayed |
018 | Entry is too long |
019 | First enter values |
020 | You may not enter an initial value here |
021 | No statistics available |
022 | Place the cursor in a field for the from value |
023 | Position cursor on a line |
024 | Attribute &1 on characteristic &2 is not available |
025 | No input help is available for attribute &1 |
026 | Value &1 is not available for attribute &2 |
027 | Planning function will be undone |
028 | There is no characteristic relationship with the number &1 |
029 | Area &1 is not a basic planning area |
030 | Multi-planning area &1 does not contain basic planning area &2 |
031 | Basic planning area &1 does not correspond to transferred basic area &2 |
055 | Make an entry in all required fields |
056 | Make an entry in field &1 |
057 | Enter a variable in field &1 |
090 | Data requested in planning area &1 is locked by user &2 |
091 | Capacity overload of lock server for planning area &1, see long text |
092 | Requested data cannot be locked. See long text |
098 | Generated report could not be inserted -> see long text |
099 | Program is inconsistent -> see long text |
200 | ***************** Basic data ******************************************** |
201 | InfoCube &1 does not exist |
202 | Error while calling up RFC |
203 | Type & could not be activated |
204 | The generated data is not contained in the selection condition |
205 | Enter a value with a permitted format in field &1 |
206 | Data must be saved first |
207 | InfoCube &1 is already being used in planning area &2 |
208 | &1 |
209 | Impermissible characteristic derivation in Customer Exit |
210 | Enter the RFC destination |
211 | RFC destination &1 is not permitted |
212 | RFC destination &1 is not a BW System with Release 1.2B or higher |
213 | InfoCube &1 contains no usable characteristics |
214 | InfoCube &1 contains no usable key figures |
215 | Transport request &1 was compiled without errors |
216 | Errors occurred during compilation of transport request &1 |
217 | You have no authorization for the requested data |
218 | You have no authorization to read the desired data |
219 | Multiplanning area &1 cannot be used |
220 | Data record is locked by data slice &1 |
221 | For SEM 2.0B FCS, you cannot use BW 2.0B yet.You can use 2.0A |
222 | You may not plan for the combination of characteristic values |
223 | Multiplanning area &1 cannot be used |
224 | &1 data records were read, &2 of them were changed, &3 generated |
225 | Only the values EQ and BT are allowed in field OPTION, not &1 |
226 | Only the value I is allowed in field SIGN, not &1 |
227 | Higher-level characteristics must be selected with single values |
228 | Planning profile &1 does not exist |
229 | Selection to characteristic &1 is not restricted |
230 | Rescheduling lead to invalid values |
231 | User &1 does not exist |
232 | Method was canceled after an error |
233 | Invalid input parameter |
234 | Value for characteristic &1 must be initial |
235 | InfoCube &1 is not a real-time InfoCube |
236 | No documents can be created in this multi area |
237 | Planning cannot be performed for real-time InfoCube &1; see long text |
238 | Selection is not suitable for any basic area |
239 | Note: Change could make Customizing invalid; see long text |
240 | Enter Customizing task |
241 | Time shift for characteristic &1, value &2, shift &3 not possible |
242 | Characteristic &1 cannot be documented |
243 | Processing of planning function was terminated |
244 | You are not authorized to use the SEM-BPS API Trace |
300 | **** Execution of planning methods |
301 | Planning function &1, parameter group &2 was carried out with no errors |
302 | Errors occurred when executing planning function &1/&2 |
303 | Object &1 |
304 | The planning function cannot be executed |
305 | Job &1 was scheduled for background processing |
306 | Report &1 could not be entered in job &2 |
307 | Fields (&1) that are not in the level, must remain initial |
308 | Global planning sequence was terminated with errors |
309 | Planning sequence &1 has been executed |
400 | ************* Hierarchy - BW Interface ********************************** |
401 | &1 |
402 | Error during data selection |
403 | No suitable data records found for selection |
404 | Parameter errors occurred during selection |
405 | Selection was cancelled |
406 | Error occurred during numbering of new hierarchy nodes |
407 | Hierarchy &1 was not found |
408 | Characteristic &1 was not found |
409 | Conversion error of value &2 (characterictic &1) |
410 | Value &2 for characteristic &1 not found |
411 | Error during text selection for characterictic &1 (value &2) |
412 | Incorrect hierarchy structure |
413 | Hierarchy &1 is not valid for date &2 |
414 | Hierarchy &1 was saved but not activated |
415 | Hierarchy ID could not be found |
416 | There is no description in the logon language for hierarchy &1 |
417 | Hierarchy &1 is maintained inconsistently |
418 | Hierarchies with link nodes cannot be used |
419 | Selected node &1 does not exist |
420 | Hierarchy &1 cannot be used |
500 | **** Maintenance characteristic relationships *************************** |
501 | Enter a basic characteristic |
502 | Maintain the entries for the hierarchy |
503 | Enter the source and target characteristic |
504 | Characteristics must be different |
505 | Characteristic &1 is not used in the hierarchy |
506 | Enter two characteristics |
507 | Characteristic &1 is not available in the planning area |
508 | Characteristic &1 is not a valid attribute of &2 |
509 | Enter a valid class name |
510 | &1 characteristic relationships were deleted |
511 | Maintain the version for the hierarchy |
512 | Maintain the validity date for the hierarchy |
513 | Enter characteristic(s) |
514 | Specify a function module |
515 | Value &1 of chara &2 does not correspond to the attrib.val &3 of chara &4 |
516 | No value &2 can be found for characteristic &3 in hierarchy &1 |
517 | The higher-level node to &1, does not have the value &2 and &3 |
518 | No value was found for node &1 (characteristic &2) in step &3 |
519 | Field &1 is not derived from characteristic relationships |
520 | &1 is not a valid key figure |
521 | No reference data available to derive |
522 | No reference data available to check |
523 | Values do not agree with reference data |
524 | No attributes exist on the characteristic |
525 | No combination could be generated in step &1 |
526 | No combinations could be generated |
527 | Characteristic combinations: No values could be found for chara. &1 |
528 | Attribute &1 on characteristic &2 with value &3 is not available |
529 | Characteristic combinations cannot be assigned to any basic area |
530 | A record contains the incorrect value &1 in the planning area field |
531 | Overflow with forecast of number of combinations |
532 | Reference data is not unique |
533 | Offset entries are only allowed for time characteristics |
534 | Variable &1 must be restricted to a value |
535 | Variable is not of the correct type |
536 | Derivation: In hierarchy &1 no value can be found for characteristic &2 |
537 | Derivation: In hierarchy &1 no value &2 exists for characteristic &3 |
538 | Error occurred in exit implementation for variable exit |
539 | You have no authorization to change the planning area |
540 | Choose at least one planning area |
541 | BW installation has changed for &1 planning areas |
542 | Choose an RFC destination |