V0 - Nachrichten Folgebildsteuerung
The following messages are stored in message class V0: Nachrichten Folgebildsteuerung.
It is part of development package BZB in software component CA-GTF-BS-SQ. This development package consists of objects that can be grouped under "R/3 Central Application Development: Subseq. Screen Proc.".
It is part of development package BZB in software component CA-GTF-BS-SQ. This development package consists of objects that can be grouped under "R/3 Central Application Development: Subseq. Screen Proc.".
Message Nr ▲ | Message Text |
|---|---|
| 000 | *** Messages for screen sequence control |
| 010 | System: More than 9 windows open: system limit reached |
| 030 | Dynpro displayed with all fields |
| 031 | Table $ is locked by another user |
| 032 | Table $ is locked by the same user |
| 033 | Global lock table is full ... |
| 034 | Local lock table is full |
| 035 | Incorrect key for locking |
| 036 | Locking error: & |
| 039 | Table & cannot be downloaded |
| 040 | Data backup table & with RC= & |
| 041 | Data saved in table $ |
| 042 | Return code > 0: Correct your entry and save if necessary |
| 050 | Internal table & not filled |
| 051 | STACK error: SY-TFILL = & and N-STACK= & |
| 052 | STACK is to be be read & times, but has only & entries |
| 060 | Flow trace can be activated or deactivated by function '&' |
| 070 | If you select ENTER, trace will be deactivated |
| 071 | Parameter selection deactivates the trace |
| 102 | Flow control: Entry & is missing in & |
| 103 | There is no next dynpro for function code & |
| 104 | Requested function & is not available here |
| 105 | Flow control: All windows are closed |
| 110 | SCREEN_SEQ._CTRL is not defined for function & (type &) |
| 150 | Dialog text is too long, it will be truncated |
| 151 | Text is longer than 70 characters: T1=$, T2=$, OB=$, WE=$ |
| 152 | Name & has more than 35 characters |
| 153 | Value & has more than 35 characters |
| 154 | Object value does not fit in the dialog text |
| 155 | POPUP_TO... reports: 'title too long' although data strings are equal |
| 200 | The program & is unknown in the SAP System |
| 201 | Texts are globally assigned to the Fcode &. Multiple use is allowed. |
| 273 | Higher-level item &1 is a Sourcing item (APO) |
| 300 | Source = A prohibits specification of follow-on screen group and panel |
| 301 | Source = & prohibits specification of follow-on parameters |
| 302 | Source = & requires specification of follow-on parameters |
| 303 | Source = & permits only non-negative memory operations |
| 304 | Memory operation 0 permitted for source = A was set |
| 305 | Source = & requires a follow-on FCode (is BLANK permitted?) |
| 306 | Source = F requires FORM routine without follow-on parameters |
| 307 | Source was set to F, since only one FORM routine specified |
| 308 | Source = & is not supported |
| 309 | Source = Z requires memory operation not equal to 0 |
| 310 | Source = & permits only negative memory operations |
| 311 | Use transaction VFBS to maintain follow-on screen control |
| 312 | Maintenance of this table is not currently permitted |
| 409 | No processing location specified |
| 410 | Only one of the & fields may contain entries |
| 411 | Do not make multiple entries for processing location |
| 412 | Dynpro in function module requires routine to be specified |
| 420 | Transaction code & not defined |
| 421 | Dynpro & does not exist |
| 800 | End of predefined path reached |
| 900 | Scheduling number & |
| 901 | Item number & |
| 902 | Material availability date & |