W8 - Workflow: Ausdr�cke, Datenfluss
The following messages are stored in message class W8: Workflow: Ausdr�cke, Datenfluss.
It is part of development package SWA in software component BC-BMT-WFM. This development package consists of objects that can be grouped under "Business Workflow: Expressions, binding".
It is part of development package SWA in software component BC-BMT-WFM. This development package consists of objects that can be grouped under "Business Workflow: Expressions, binding".
Message Nr ▲ | Message Text |
|---|---|
| 001 | & is not a valid & & input value |
| 002 | Error '&1' during deletion. Try again later |
| 003 | Declare constants for object references using input help |
| 004 | Value & does not correspond to the data type & of element & |
| 005 | Parameter error calling function & |
| 006 | Parameter error while calling function & (in function &) |
| 020 | The interface of function module '&1' does not correspond to conventions |
| 021 | Function modules correspond to workflow conventions |
| 051 | &1 errors occurred in binding assignment to &2 |
| 052 | &1 errors occurred in binding assignment to &3 |
| 053 | &1 errors occurred in the condition evaluation of &2 |
| 060 | Table action "Append" is only possible for single-level expressions |
| 063 | Reference '&1'('&2') has changed - binding adapted for '&3' |
| 064 | Conversion error while evaluating expression |
| 065 | Conversion error while evaluating condition & = & & & |
| 066 | Value for expression &1 cut |
| 067 | Text is too long |
| 068 | Data was saved |
| 069 | Input not supported for structured elements with data type '&1' |
| 070 | Reference structure & for expression & is not a valid structure |
| 071 | Element & has no structure reference, therefore no access to fld & in & |
| 072 | No access to field & in element & (expression & ) possible w/o structure |
| 073 | Element & from expression & is incompatible with structure & |
| 074 | Element & cannot be read with structure & |
| 075 | Source and target structures have different numbers of fields (&, &) |
| 076 | Saving element & contradicts structure & |
| 077 | Access to field & is not possible for multiline element & |
| 078 | Access to attribute & is not possible for multiline element & |
| 079 | Structure & has no field with name & |
| 080 | Structures & and & are not compatible |
| 081 | Element & does not refer to a structure |
| 082 | Element value with reference structure & becomes CHAR string of length & |
| 083 | CHAR string of length & becomes value with reference structure & |
| 084 | Access with line index () is not possible for element & (one line) |
| 085 | Access with line index () is not possible for expression part & |
| 086 | Object type & overwritten by object type & in target element |
| 087 | Source element & does not exist; target element & will be deleted |
| 088 | Source & corresponds to object type & and not & |
| 089 | Time specifications require the formatting defined in user defaults |
| 090 | Date specifications require the formatting defined in user defaults |
| 091 | Time specifications are expected in the internal format HHMMSS |
| 092 | Date specifications are expected in the internal format YYYYMMDD |
| 093 | Expression '&1' has an invalid length |
| 094 | Binding for element '&3' adapted to new data type or length |
| 095 | Element & may not be changed |
| 096 | Syntax '()' only allows read access to element & |
| 097 | Element & does not have a line with index & |
| 098 | Syntax '()' is only possible for elements of the container |
| 099 | Values in binding have maximum length & |
| 100 | No container definition available |
| 101 | Binding for container types & <- & is not defined |
| 102 | Parameter error calling editor for binding & <- & |
| 103 | Fast entry cannot be used for entry of individual elements |
| 104 | Binding definition inconsistent with (called) container definition & |
| 105 | Container element & is not loop element & |
| 106 | Constants cannot begin with '%' or '&' |
| 107 | No binding defined for mandatory import parameter & |
| 108 | Source & corresponds to object type & and not & |
| 109 | Reference types '&1' and '&2' are not compatible (expression '&3') |
| 110 | Syntax error in expression &1 |
| 111 | Parameter error calling editor for expression & |
| 112 | Specify a reference for expression & |
| 113 | Result (length &) is too short for source (length &) |
| 114 | The source field of a date cannot have the length & |
| 115 | The source field of a time cannot have the length & |
| 116 | The data type & cannot be converted to data type & |
| 117 | No definition exists in container &2 for element '&1' |
| 118 | Binding definition is consistent |
| 119 | ***** Binding definition: Direction "&", element & ***** |
| 120 | Messages were created when checking the expression -> see log |
| 121 | Variable does not have a & end character |
| 122 | Index element & does not have a & end character |
| 123 | '&1' is not an attribute of '&2' - use the F4 input help |
| 124 | Conversion of data type & to data type & is not supported |
| 125 | Object type & does not exist |
| 126 | Element & is not the specified table element & |
| 127 | & binding for element & has a critical error |
| 128 | Binding definition contains errors -> see Check |
| 129 | Table action not possible on element & |
| 130 | Table action "Append" not possible when reading an element |
| 131 | Multiline element & cannot be assigned to a single-line element |
| 132 | Expression & is an object and not a DDIC reference |
| 133 | Element & has been defined as single-line but can now become multiline |
| 134 | Assignment of variable object type & to object type & may contain errors |
| 135 | Input value & is not allowed |
| 136 | Expression type & is not supported |
| 137 | Constants cannot be declared here |
| 138 | Import elements cannot be processed since no source container defined |
| 139 | Element & not in source container |
| 140 | The respective element in & has no value |
| 141 | No element & in target container |
| 142 | Expression & refers to container elements that do not incorporate export |
| 143 | Attribute & cannot be overwritten |
| 144 | No container defined for & |
| 145 | Object type & overwrites initial object type of target element |
| 146 | & is not a valid entry |
| 147 | Container definition passed is empty |
| 148 | Declare either a system status or a user status |
| 149 | Function only allowed for data type CHAR (not for data type &) |
| 150 | Invalid data type for passing expression & |
| 151 | Expression type & has no processing for expression & |
| 152 | Expression & only allows single-line values |
| 153 | Object type & does not have any key fields |
| 154 | Element & from expression & is not in container |
| 155 | Object & could not be instantiated |
| 156 | Cursor does not show binding direction |
| 157 | Element & could not be recognized as an object reference |
| 158 | Value for container element & is initial, no attributes can be determined |
| 159 | Element & will not be overwritten |
| 160 | Lines that cannot be processed in the binding definition will be deleted |
| 161 | A constant cannot be assigned to a table element |
| 162 | Element & does not have a reference type (see container definition) |
| 163 | Object types & and & are not compatible |
| 164 | A table element cannot be assigned a system field |
| 165 | No appropriate elements for reference of & in container & |
| 166 | This function is not possible for element & |
| 167 | Select a container element |
| 168 | Error converting entry for field &-& |
| 169 | Error during input for element & |
| 170 | Error during type conversion |
| 171 | Date or time & does not exist |
| 172 | Conversion of format & is not currently supported |
| 173 | Reference field &-& for element & does not exist |
| 174 | Constants are restricted to only 80 characters |
| 175 | Expression & does not have a valid date format or time format |
| 176 | Value '&1' has an invalid length (&2) for the field '&3' |
| 177 | Enter the value for element & using the input help |
| 178 | Value of element & will be deleted from the container |
| 179 | Binding & & & will be deleted |
| 180 | This function is not available for binding direction ==> |
| 181 | Data type incompatible |
| 182 | References '&1' and '&2' are not compatible |
| 183 | Element & is assigned data for all source elements |
| 184 | Element & is the source for all target elements |
| 185 | Existence of object ( & & ) was not checked |
| 186 | Expression & is not a constant |
| 187 | Logical system & is not valid (current system: & ) |
| 188 | Element & is only intended for data export |
| 189 | The one line element & already contains the value & |
| 190 | Field or field value restrictions are only valid for "change" event & |
| 191 | Field or field value restrictions for "change" event only |
| 192 | Value & exists in client &, but check table & is client-specific |
| 193 | Value & is invalid in client &, but check table & is client-specific |
| 194 | Value & is allowed in language &, but check table & is language-specific |
| 195 | Value & is invalid in language &, but check table & is language-specific |
| 196 | Value & cannot be checked against table & |
| 197 | Reference field & - & for expression & does not exist |
| 198 | Value of type & is used for defining date (type &) |
| 199 | Expression '&' does not correspond to data type (&) of element & |
| 200 | Internal error in HTML generation: Line length exceeded (&) |
| 201 | Error in text replacement: '&1' is not in the container of WI &2 |
| 202 | Error in text replacement: Element '&1' does not exist in the container |
| 207 | No binding for required element &1&, use default value |
| 210 | Condensing of containers not supported for element &1 |
| 220 | Expression &1: Invalid syntax for access to structure field |
| 225 | Expression &1 does not type timestamp (TIMESTAMP, TIMESTAMPL). |
| 240 | Function module '&1' does not exist |
| 241 | Internal error accessing function module '&1' |
| 242 | Operation terminated |
| 243 | Binding module '&1' created in function group '&2' |
| 300 | *** Reserved for condition editor (300 - 399) |
| 301 | Function '&' not yet implemented |
| 302 | Internal program error: & & & & |
| 303 | The evaluation of the condition gives the result 'True' |
| 304 | The evaluation of the condition gives the result 'False' |
| 305 | Select a line area first |
| 306 | Only related lines can be selected as an area |
| 307 | Syntax check: The condition is correctly formulated |
| 308 | Row is incomplete |
| 309 | Add a relational operator (<, >, =, etc.) to line &1 |
| 310 | Operator '&' cannot be used in this position |
| 311 | Add a logical operator (AND, OR) to line &1 |
| 312 | Object type &1 does not have a method for checking existence |
| 313 | Existence check not successful for '&' |
| 314 | Perform the test first |
| 315 | Existing selection removed |
| 316 | No messages exist |
| 317 | Data converted |
| 318 | Select a suitable entry |
| 319 | Position the cursor on an expression |
| 320 | Position the cursor in column 'Expression 1' or 'Expression 2' |
| 321 | Choose a relational operator in the condition first |
| 322 | Choose a line in the condition by double-clicking |
| 323 | Simulated evaluation of the condition returns &1 error(s) |
| 324 | Maximum number of lines (&1) reached - operation aborted |
| 325 | Logical operator &1 (in line &2) is not permitted |
| 326 | No data stored currently |
| 327 | Define constants only on the right-hand side of the operator |
| 328 | Could not establish the type of expression '&' |
| 329 | Cursor automatically positioned on expression &1 |
| 330 | Expression not (yet) defined - no attributes available |
| 333 | &1 line(s) cut and moved to buffer |
| 334 | &1 line(s) copied to buffer |
| 335 | &1 line(s) inserted from buffer |
| 336 | Error accessing local file - operation aborted |
| 340 | Too many closing parentheses in line &1 |
| 341 | Opening parenthesis in line &1 not closed |
| 344 | Evaluation returns 'true'. &1 message(s) exist |
| 345 | Evaluation returns 'false'; &1 message(s) exist |
| 350 | Expression 1 ('&2') must be multiline for operator '&1' |
| 351 | Expression 2 ('&2') cannot be multiline for operator '&1' |
| 352 | Operator '&1' can only be applied to an object reference |
| 353 | Operator '&1' cannot be applied to a multiline element |
| 354 | Operator '&1' allows only one operand |
| 370 | The selected expression exceeds the maximum length allowed (&1) |
| 380 | Condition '&' saved and type linkage &.& <-> & created |
| 381 | Condition '&' saved and activated |
| 382 | Condition '&' deleted and type linkage updated |
| 383 | Condition '&1' saved (&2) |
| 384 | Condition '&1' deleted |
| 385 | Processing aborted - condition '&' not changed |
| 386 | No condition created |
| 387 | Condition '&1' not changed (&2) |
| 388 | Condition '&1' deleted with associated linkage '&2 <-> &3' |
| 389 | Attributes of condition '&1' changed |
| 396 | Mode switch not effective until next time condition editor called |
| 397 | Welcome to the condition editor (traditional mode) ... |
| 398 | Welcome to the condition editor ... |
| 399 | *** Reserved for workflow condition editor (300 - 399) |
| 401 | Invalid command '&1' received from HTML control |
| 402 | Invalid line index (&1) accessing internal table |
| 403 | Internal error: Invalid field lengths (SWBTYPECOU <-> SWBRULECOU) |
| 404 | Object type '&1' does not exist in Business Object Repository |
| 405 | Linkage for '&1-&2' <-> '&3' could not be created |
| 406 | Workflow & not found - enter a valid workflow ID |
| 408 | Attributes not changed |
| 409 | Personal settings saved |
| 410 | Internal error saving personal settings |
| 411 | HTML control: Error accessing resource '&1' |
| 412 | Change of name or currency of start condition not possible |
| 413 | Event linkage '&1'<->'&2.&3' deactivated |
| 414 | Event linkage '&1'<->'&2.&3' activated |
| 415 | Error accessing linkage '&1'<->'&2' |
| 416 | Start condition '&1' activated |
| 417 | Start condition '&1' deactivated |
| 418 | New default currency for start condition '&1': &2 |
| 419 | Default currency for start condition '&1' not changed |
| 420 | Name of start condition '&1' not changed |
| 421 | New name for start condition: '&1' |
| 422 | Object type '&1' defines no events. Use not possible. |
| 423 | Create a start condition; click the required event linkage |
| 424 | Choose a workflow task of type WS, WF, TS or T |
| 425 | Start condition being processed by user &1 - Only display possible |
| 426 | To process the start condition, choose change mode |
| 427 | Your selection was not changed |
| 428 | Start condition '&1' could not be activated |
| 430 | There are changes that have not been assigned to a transport request |
| 431 | There are no changes relevant for transport |
| 432 | Operation was canceled |
| 433 | &1 start condition(s) passed to transport request |
| 434 | No transport entries created |
| 435 | No exchange rate found for currency conversion '&1' -> '&2' |
| 436 | Error during currency conversion '&1' -> '&2' |
| 500 | *** Reserved for event manager (build time) *** |
| 501 | Incorrect parenthesis type used |
| 502 | Field restriction entered contains syntax errors |
| 503 | Field restriction entered does not contain entry '&1' at least |
| 504 | Field restriction entered correct and saved |
| 505 | Maximum field length exceeded |
| 506 | Entry '&1' not permitted syntactically |
| 515 | Conversion of field restriction not possible |
| 516 | Combined field restriction not correct syntactically |
| 518 | Old field restrictions successfully restored |
| 520 | Conversion only possible for field restrictions without entry KEY |
| 521 | Field restrictions and a combined field restriction exist |
| 522 | Combined field restriction could not be saved |
| 523 | A combined field restriction already exists |
| 525 | An old combined field restriction exists and is being loaded. |
| 526 | Field restrictions exist that have not yet been converted |
| 530 | Event container function module entry not saved |
| 531 | Event container function module entry saved |
| 532 | Combined field restriction could not be read |
| 533 | Save modified field restriction(s) |
| 600 | **** Reserved for SWA utility functions ****************************** |
| 601 | Field &1 can only take the first &2 characters of the result string |
| 602 | The maximum length supported for character strings here is &1 characters |
| 700 | Enter the business object type |
| 701 | Enter an event |
| 702 | Entry is inconsistent |
| 703 | Not more than 999 entries allowed for change document object |
| 704 | Change document object & does not exist |
| 705 | Enter a change document object |
| 706 | Key for change doc. object & and business object type & are incompatible |
| 707 | Internal error occurred during key check |
| 708 | No key information for change document object & |
| 709 | Internal error during event parameter check |
| 710 | Some parameters of event are not assigned values during creation |
| 711 | Internal error accessing database |
| 712 | No change document written for & when changed |
| 713 | No change document written for & when created |
| 714 | No change document written for & when deleted |
| 715 | Table & not used for change document object & |
| 716 | Enter a table for change document object & |
| 717 | Field & does not occur in table & |
| 718 | Creation/deletion of records in table & checked |
| 719 | Event & can only be a triggering event |
| 720 | Workflow requester flag only valid for create events |
| 721 | Status object and business object type keys incompatible |
| 722 | No key information exists for status object & |
| 723 | Field name 'KEY' can be used to check create/delete for table & |
| 724 | Only system status & or user status & possible |
| 725 | Event only triggered in case of change |
| 726 | Field & is not part of change document |
| 727 | Enter object type and event |
| 728 | Key already exists for change document object & |
| 729 | Business object type and change document object are incompatible |
| 730 | No transport request created |
| 800 | *** Reserved for trace manager *** |
| 801 | Workflow trace for work item &1 switched on (trace ID &2) |
| 802 | Workflow trace for work item &1 switched off |
| 803 | Job scheduling successful |
| 804 | Job & scheduled |
| 805 | A system error has occurred |
| 806 | Workflow trace & switched on for workflow |
| 807 | Workflow trace & switched off for workflow |
| 808 | Container debugging switched on |
| 809 | Container debugging switched off |
| 810 | Stored workflow trace cannot be deleted |
| 811 | &1 new entries |
| 812 | &1 from &2 entries will be displayed |
| 813 | &1 entries were found |
| 814 | Job & could not be scheduled |
| 899 | & & & & |
| 998 | No authorization to change an existing start condition |
| 999 | No authorization to create a new start condition |