Message Nr ▲ | Message Text |
---|---|
001 | No data aging object could be determined for BOPF BO &1 |
002 | The DB of BOPF BO node &1-&2 can't be used for Data Aging |
003 | Internal error occurred in class &1, method &2 |
004 | Undo for data aging without any limitation is not supported |
005 | &2 docs. were not aged; no Customizing found for doc. type '&1' |
006 | &1 docs. were not aged; they are still in their residence period |
007 | &1 docs. were not aged; not all related docs. are ready for aging |
008 | The document is already aged; undo aging before reopening it |
009 | No residence time defined for data aging object &1; aging run aborted |
010 | Reuse data aging object &1 could not set into test mode |
011 | &1 docs. were not aged due to incomplete Customizing settings |
019 | Data aging run started for data aging object &1 |
020 | Test data aging run for aging object &2 (BOPF BO &1) |
021 | &1 documents will be checked by the data aging test run |
022 | The data aging test run was executed with the following parameters: |
023 | - Query: &1, Query Attribute: &2 |
024 | - Sel. Value: Sign=&1, Option=&2, Low=&3, High=&4 |
025 | ------------------------------------------------------------------------- |
026 | Execute if_daag_runtime~init() |
027 | Execute if_daag_runtime~process() |
028 | After execution of if_daag_runtime~process(): Call again=&1 |
029 | After execution of if_daag_runtime~init() |
030 | Expiration time (in days) for data aging run log: &1 |
031 | Package size for processing: &1 |
032 | Maximum tasks for parallel processing: &1 |
033 | Reference field for residence time: &1 |
034 | An exception was raised when adding a message to the data aging log |
035 | Aged business documents: &1 |
036 | Partial data aging active |
037 | - Selected data keys for database table &1: &2 |
038 | Latest maximum date of data aging: &1 |
039 | Processing Reuse Data Aging Object: &1 |
040 | Data aging run aborted |
041 | - No data found |
042 | Data aging data container health check: |
043 | - Data found for &1 tables |
044 | - &1 rows found for table &2 |
045 | - Data temperature is consistent |
046 | - &1 rows found with initial data temperature |
047 | - &1. key with initial data temperature: &2 |
048 | - And &1 more key(s)... |
049 | - Check all available documents |
050 | Business documents being checked for data aging: &1 |
051 | Execute if_daag_adjustment~run_final() |
052 | Add remaining &1 business documents to the current process package |
053 | Queue &1 business documents for the next process package |
054 | - No data found with reference field &1 |
060 | Data aging object &1 for BOPF BO &2 not found in the system |
061 | Database table &1 of BO &2 is missing in related data aging object &3 |