/BOFU/DAAG - Messages of the BOPF Data Aging Runtime

The following messages are stored in message class /BOFU/DAAG: Messages of the BOPF Data Aging Runtime.
It is part of development package /BOFU/DATA_AGING in software component CA-EPT-BRC. This development package consists of objects that can be grouped under "Data Aging Runtime for BOPF BOs".
Message Nr
Message Text
001No data aging object could be determined for BOPF BO &1
002The DB of BOPF BO node &1-&2 can't be used for Data Aging
003Internal error occurred in class &1, method &2
004Undo for data aging without any limitation is not supported
005&2 docs. were not aged; no Customizing found for doc. type '&1'
006&1 docs. were not aged; they are still in their residence period
007&1 docs. were not aged; not all related docs. are ready for aging
008The document is already aged; undo aging before reopening it
009No residence time defined for data aging object &1; aging run aborted
010Reuse data aging object &1 could not set into test mode
011&1 docs. were not aged due to incomplete Customizing settings
019Data aging run started for data aging object &1
020Test data aging run for aging object &2 (BOPF BO &1)
021&1 documents will be checked by the data aging test run
022The data aging test run was executed with the following parameters:
023- Query: &1, Query Attribute: &2
024- Sel. Value: Sign=&1, Option=&2, Low=&3, High=&4
025-------------------------------------------------------------------------
026Execute if_daag_runtime~init()
027Execute if_daag_runtime~process()
028After execution of if_daag_runtime~process(): Call again=&1
029After execution of if_daag_runtime~init()
030Expiration time (in days) for data aging run log: &1
031Package size for processing: &1
032Maximum tasks for parallel processing: &1
033Reference field for residence time: &1
034An exception was raised when adding a message to the data aging log
035Aged business documents: &1
036Partial data aging active
037- Selected data keys for database table &1: &2
038Latest maximum date of data aging: &1
039Processing Reuse Data Aging Object: &1
040Data aging run aborted
041- No data found
042Data aging data container health check:
043- Data found for &1 tables
044- &1 rows found for table &2
045- Data temperature is consistent
046- &1 rows found with initial data temperature
047 - &1. key with initial data temperature: &2
048 - And &1 more key(s)...
049- Check all available documents
050Business documents being checked for data aging: &1
051Execute if_daag_adjustment~run_final()
052Add remaining &1 business documents to the current process package
053Queue &1 business documents for the next process package
054- No data found with reference field &1
060Data aging object &1 for BOPF BO &2 not found in the system
061Database table &1 of BO &2 is missing in related data aging object &3
Privacy Policy