/BOFU/FC_MSG - BO Field Control Messages

The following messages are stored in message class /BOFU/FC_MSG: BO Field Control Messages.
It is part of development package /BOFU/FIELD_CONTROL in software component CA-EPT-BRC. This development package consists of objects that can be grouped under "BO FIeld Control".
Message Nr
Message Text
001Value &1 is not expected
002Value is expected
020**************** Consistency Check Messages ****************
021Field control profile &2 for the business object &1 does not exist
022Node &1 of business object &2 is not participating in field control
023Node &1 of BO &2 does not have field control context structure
024Node profile &1/&2; disabled attribute &3 cannot be mandatory
025Node profile &1/&2; disabled attribute &3 cannot be read only
026Node profile &1/&2; read only attribute &3 cannot be mandatory
027Node profile &1/&2; disabled association &3 cannot create enabled
028Save rejected due to errors
029No active field control profile found for business object &1
030Field control node profiles not found for business object &1, node &2: &3
032Error calling BOPF: &1
033&1 is not a BOPF modelled business object
034&1 is not a valid node on the business object &2
035Datatype &1 of BO node &2/&3 is invalid
036Datatype &1 of BO node &2/&3 is not a structure
037Node profile &1/&2; attribute &3 is not part of data structure &4
038&1 is not a standard node on the business object &2
039Node profile &1/&2; association &3 is not valid for the node
040Node profile &1/&2; action &3 is not valid for the node
041Business object &1; field control profile: &2; check results
042Node profile &1/&2; create enabled assoc &3 cannot create enable subhier
043Node profile &1/&2; create enabled assoc &3 cannot enable subhier actions
044Node profile &1/&2; update enable cannot create enable subhier
045Node profile &1/&2; update enable cannot enable subhier actions
046Business object &1; field control profile: &2; checking DB data
047Business object &1; field control profile: &2; checking changed data
048Comm. Structure &1 of BO Node &2/&3 is not found
049Comm. Structure &1 of BO Node &2/&3 is not a structure
050Importing TMS BO Field Control data: After Import Method started &1
051Invalidating BO Field Control Profile &1/&2/&3 on all servers
052&1 BO Field Control Profiles were invalidated on the shared memory
053Importing TMS BO Field Control data: After Import Method finished &1
054Node Profile &1/&2: Field &3 is not found on comm. structure &4
055Node Profile &1/&2: Field &3 of comm. structure &4 is not a boolean
Privacy Policy