/CLMDV/DVF_TEST_SPEC - Message Class for Test Specifications
The following messages are stored in message class /CLMDV/DVF_TEST_SPEC: Message Class for Test Specifications.
It is part of development package /CLMDV/TEST_SPECIFICATION in software component BC-UPG-DVF. This development package consists of objects that can be grouped under "Test Specification".
It is part of development package /CLMDV/TEST_SPECIFICATION in software component BC-UPG-DVF. This development package consists of objects that can be grouped under "Test Specification".
Message Nr ▲ | Message Text |
---|---|
000 | Project ID is missing. Enter the ID |
001 | &1 already exists. Choose a different ID |
002 | &1 does not exist. Check and enter the correct project ID. |
003 | Project &1 copied with the initial status.Review the steps to proceed. |
004 | Project &1 is renamed as &2 |
005 | Project &1 data deleted successfully |
006 | Invalid operation. Choose a valid operation |
007 | &1 is an invalid entry. Enter project ID with no space(s). |
008 | Project &1 saved |
009 | Project ID is too long. Enter maximum of 35 characters. |
010 | Save failed. System &1 and system &2 are same.OR Save failed. From System |
011 | Save failed. Remove the empty line. |
012 | Data saved successfully |
013 | Enter high values for range conditions, such as BT and NB. |
014 | Split condition is valid |
015 | Invalid split. Narrow down the selection |
016 | Valid split. Performance issue may occur |
017 | System error. Check the table or report name. |
018 | System name missing. |
019 | Duplicate system ID found. |
020 | Select a system from the drop-down list. |
021 | System ID must have alpha-numeric characters. |
022 | Table name is missing. |
023 | Table name must have alpha-numeric characters. |
024 | Duplicate table name found. |
025 | Maintain all field values. |
026 | System &1 and System &2 are same. Change the system and save. |
027 | Space, special character not allowed. Underscore allowed. Change and save |
028 | Project locked by another session. You cannot make the changes now. |
029 | Field &1 is initial. Enter a value |
030 | Invalid characters for field &1. Enter alpha-numeric charecters only and |
031 | Field &1 exceeds character limit. Emter maximum of &2 characters. |
032 | Error while creating container |
033 | Simulation started. Refresh to check the simulation status |
034 | Simulation completed |
035 | Invalid report name &1 |
036 | Extraction started in background. Refresh to check latest status. |
037 | Extraction data has been reset successfully. |
038 | Extraction completed successfully. |
039 | All running jobs have been cancelled. |
040 | Restart process sstarted in backgorund. Refresh to check latest status. |
041 | Re-extraction started for selected items. Refresh to check latest status. |
042 | Old name &1 and new name &2 in Report Header cannot be the same. |
043 | Save Rejected. Maintain a value for mandatory parameter Output Type. |
044 | RFC does not exist |
045 | Duplicate object name found |
046 | Duplicate object mapping found |
047 | Item data without header data cannot be saved |
048 | Select system from dropdown. |
049 | Invalid variant name |
050 | Test Specification does not exist |
051 | Parameter name &1 incorrect |
052 | Data Upload Successful. |
053 | Simulation is either in progress or completed. Reset to re-simulate. |
054 | Simulation has either been completed or not started. |
055 | Simulation is either in progress or has not been started. |
056 | No authorization |
057 | Error during authority check |
058 | You have display authorization |
059 | Extraction results exists for &1. Click Re-run to execute again. |
060 | Selected test specification is not run or In Progress. Reset not allowed. |
061 | Only test specifications in 'In Progress' can be cancelled. |
062 | Only test specifications in 'Failed' or 'Cancelled' can be resumed. |
063 | One or more test specification(s) is not run. Check and Re-Run again. |
064 | No authorization for implemention |
065 | No authorization for execution |
066 | Connection error at remote system &1 (RFC-ID: &2) |
067 | Missing authorization in remote system &1 (RFC-ID: &2) |
068 | Lock for synchronous reset cannot be acquired. |
069 | Not all nodes could be reset |
070 | Workitem &1 already exists |
071 | Error during authority check in remote system &1 (RFC-ID: &2) |
072 | Error during writing result data |
073 | Cancelled by user |
074 | Evaluation results exists for &1. Click Re-run to execute again. |
075 | Action cancelled by user |
076 | Invalid systems in the test specification |
077 | Select a Pre-delivered Content for Import. |
078 | Import Completed. |
079 | For already imported content, a new test specification will be created. |
080 | Evaluation cannot be executed for more than two systems |
081 | Save Rejected. Name missing. |
082 | Save rejected. Maintain &1 in &2. |
083 | Maintain systems in the project |
084 | Maintain system role |
085 | Duplicate object name found. |
086 | Status of Step changed to &1. |
087 | Maintain only one value - either executing server or executing group |
088 | Extraction is still in progress. Wait for completion. |
089 | Enter valid executing group |
090 | Enter valid executing server |
091 | Table name must contain alpha numeric characters |
092 | For Equals, there should be no high value. |
093 | Change(s) here could affect the test specification consistency. |
094 | Duplicate entry found in &1. |
095 | Old Value &1 and New Value &2 in Object Value Mapping cannot be the same. |
096 | Select a table name to fetch table attributes |
097 | Select a test specification |
098 | For report &1, system &2 conditions will be ignored since it has variant. |
099 | Name missing. Enter a project name. |
100 | Maintain systems in Read mode |
101 | Maintain systems in write mode |
102 | Table analysis in write mode |
103 | Table analysis in read mode |
104 | Maintain rules and filter in write mode |
105 | Maintain rules and filter in read mode |
106 | Pre delivered content in write mode |
107 | Pre delivered content in read mode |
108 | Project global data in write mode |
109 | Project global data in read mode |
110 | Define test specification in write mode |
111 | Define test specification in read mode |
112 | Execute data extraction in write mode |
113 | Execute data extraction in read mode |
114 | Evaluate data in write mode |
115 | Evaluate data in read mode |
116 | Summary in write mode |
117 | Summary in read mode |
118 | Manage project in write mode |
119 | Manage project in read mode |
120 | Refresh to check the simulation status |
121 | Simulation error. Check simulation results. |
122 | Changes to the test specification will affect the simulation results. |
123 | All the subsequent steps would be marked to InProgress. |
124 | Evaluation started in background. Refresh to check latest status. |
125 | Only executable nodes can be processed. |
126 | Extraction data reset and simulation results are shown. |
127 | Project &1 is created. Review the steps to proceed. |
128 | Project &1 is set to default. |
129 | Table &1 doesn't exist. |
130 | Caution: Import XML overwrites the existing content. |
131 | Save rejected. For &1, maintain &2 in &3. |
132 | For &1, &2 contains special characters in &3. Change and save. |
133 | Simulation reset. |
134 | Simulation has not been started. |
135 | System date is not greater than date retention |
136 | Project deletion not possible for this status |
137 | Project deleted successfully |
138 | Re-evaluation started for selected items. Refresh to check latest status. |
139 | Date can not be before project creation date |
140 | Select a file |
141 | Project copied successfully |
142 | Project not copied |
143 | Project not deleted |
144 | Project deleted successfully |
145 | Project deletion not possible for this status |
146 | Extracted data deleted successfully |
147 | File downloaded successfully |
148 | File imported successfully |
149 | System is locked |
150 | Only successfully finished simulation results can be imported |
151 | Passed : Valid selection |
152 | Failed : Check logs |
153 | Passed : Reconsider selection |
154 | Form can not be genrated |
155 | Evaluation is still in progress. Wait for completion. |
156 | Global data missing for &. |