/CWM/LES - CW Delivery
The following messages are stored in message class /CWM/LES: CW Delivery.
It is part of development package /CWM/S4_LE in software component MM-IM-GF-CWM. This development package consists of objects that can be grouped under "CWM S4 LE".
It is part of development package /CWM/S4_LE in software component MM-IM-GF-CWM. This development package consists of objects that can be grouped under "CWM S4 LE".
Message Nr ▲ | Message Text |
---|---|
000 | &1 not a parallel unit of measure; entry not permitted |
001 | PUoM delivery quantity &1 &2 <> PUoM pick qty &3 &4; transfer pick qty |
002 | Add the parallel quantity and unit of measure |
003 | No cumulated posting for PUoM w/o HUM. Reposting takes place immediately |
004 | Remaining parallel quantity in delivery is less than the quantity 0 |
005 | You cannot put back & & as the delivery item only contains & & |
006 | Pick quantity = &. Parallel quantity in delivery must not be & |
007 | Pick quantity is 0. Parallel quantity is also set to 0 |
008 | In HU environment, parallel quantity must be entered at pick step |
009 | Determine the destination storage unit first |
010 | Internal error during WM inventory adjustment with handling units |
011 | Select the relevant storage unit |
012 | Picked parallel quantity &1 different to delivery parallel quantity &2 |
013 | Packing quantity in PUoM &1 &2 <> delivery quantity in PUoM &3 &4. |
014 | Delivery quantity in delivery unit & = 0, but in parallel unit & > 0 |
015 | Mixed storage units cannot be transferred automatically |
016 | Enter the difference with the "Difference in Parallel Quantity" button |
017 | Based on bin section &, no space is left in the storage bin |
018 | TO item &1. Tolerance group &2 exceeded (max: &3 % actual: &4 %) |
019 | TO item &1. Tolerance group &2 min. not met (max: &3 % actual: &4 %) |
020 | No quant found for storage unit & |
021 | Input data did not correspond to any quant in storage unit & |
022 | Internal error occurred when processing physical inventory document & |
023 | Dynamic cycle counting not supported for physical inventory & item & |
024 | Physical inventory &, item & has the status "partially counted" |
025 | Physical inventory &/item & already counted for storage unit & |
026 | In the system, SU is in category &, bin &. Transfer automatically? |
027 | Automatic transfer completed successfully |
028 | Errors occurred during automatic stock transfer |
029 | Physical inventory &, item & already has status "counted" |
030 | CW: Immed. confrmtn for mvmt type & only w. screen control TO conf. = 2 |
031 | Impossible to save as remaining qty of HU would be & & & |
032 | Process not supported in CWM |
034 | IDoc type &1 can only be processed with BF &2 |
035 | Goods posting of delivery item &1 has already been started |
101 | Item &1 contains parallel unit of measure; Confirm using entry list |
103 | You have entered a parallel unit of measure, enter unit of measure also |
104 | Unit of measure is not permitted as parallel unit of measure |
105 | Enter the parallel quantity for this item |
106 | Parallel quantity not entered for &/&, although logistics qty entered |
107 | Error status &1 when function module &2 called |
108 | Internal error in program &1, error value &2 |
109 | Interal error; Value 2 not permitted here for field LTAP-/CWM/IND_CATCH |
110 | Internal error; No changes allowed to BAdI parameter (old &1, new &2) |
111 | Immediate confirmation not supported for CW material |
112 | This function is not allowed for CW materials |
113 | Function module &1 is not executed in CWM |
114 | Automatic change of storage location not allowed in CWM |
115 | Late delivery update not allowed in CWM |
116 | Bulk storage not supported by the CWM |
117 | Difference ind.: Post CW diffs for delivery to source storage bin only |
118 | Handling unit &1 does not exist |
119 | Handling unit &1 is locked |
120 | Delivery &1: No support for function for CW-relevant TOs |
121 | Change Management not supported for CW items |
122 | Immediate confirmation for CW only possible in HU environment |
123 | Default quantity calculated using plan conversion factor of material |
124 | This unit or measure is not allowed as a logistics unit of measure |
125 | CW material &1 / &2 - fill logistical and parallel quantity |
126 | SC components are ignored as one component is a CW material |
127 | Switch to display mode as components contain CW materials |