/CWM/LES - CW Delivery

The following messages are stored in message class /CWM/LES: CW Delivery.
It is part of development package /CWM/S4_LE in software component MM-IM-GF-CWM. This development package consists of objects that can be grouped under "CWM S4 LE".
Message Nr
Message Text
000&1 not a parallel unit of measure; entry not permitted
001PUoM delivery quantity &1 &2 <> PUoM pick qty &3 &4; transfer pick qty
002Add the parallel quantity and unit of measure
003No cumulated posting for PUoM w/o HUM. Reposting takes place immediately
004Remaining parallel quantity in delivery is less than the quantity 0
005You cannot put back & & as the delivery item only contains & &
006Pick quantity = &. Parallel quantity in delivery must not be &
007Pick quantity is 0. Parallel quantity is also set to 0
008In HU environment, parallel quantity must be entered at pick step
009Determine the destination storage unit first
010Internal error during WM inventory adjustment with handling units
011Select the relevant storage unit
012Picked parallel quantity &1 different to delivery parallel quantity &2
013Packing quantity in PUoM &1 &2 <> delivery quantity in PUoM &3 &4.
014Delivery quantity in delivery unit & = 0, but in parallel unit & > 0
015Mixed storage units cannot be transferred automatically
016Enter the difference with the "Difference in Parallel Quantity" button
017Based on bin section &, no space is left in the storage bin
018TO item &1. Tolerance group &2 exceeded (max: &3 % actual: &4 %)
019TO item &1. Tolerance group &2 min. not met (max: &3 % actual: &4 %)
020No quant found for storage unit &
021Input data did not correspond to any quant in storage unit &
022Internal error occurred when processing physical inventory document &
023Dynamic cycle counting not supported for physical inventory & item &
024Physical inventory &, item & has the status "partially counted"
025Physical inventory &/item & already counted for storage unit &
026In the system, SU is in category &, bin &. Transfer automatically?
027Automatic transfer completed successfully
028Errors occurred during automatic stock transfer
029Physical inventory &, item & already has status "counted"
030CW: Immed. confrmtn for mvmt type & only w. screen control TO conf. = 2
031Impossible to save as remaining qty of HU would be & & &
032Process not supported in CWM
034IDoc type &1 can only be processed with BF &2
035Goods posting of delivery item &1 has already been started
101Item &1 contains parallel unit of measure; Confirm using entry list
103You have entered a parallel unit of measure, enter unit of measure also
104Unit of measure is not permitted as parallel unit of measure
105Enter the parallel quantity for this item
106Parallel quantity not entered for &/&, although logistics qty entered
107Error status &1 when function module &2 called
108Internal error in program &1, error value &2
109Interal error; Value 2 not permitted here for field LTAP-/CWM/IND_CATCH
110Internal error; No changes allowed to BAdI parameter (old &1, new &2)
111Immediate confirmation not supported for CW material
112This function is not allowed for CW materials
113Function module &1 is not executed in CWM
114Automatic change of storage location not allowed in CWM
115Late delivery update not allowed in CWM
116Bulk storage not supported by the CWM
117Difference ind.: Post CW diffs for delivery to source storage bin only
118Handling unit &1 does not exist
119Handling unit &1 is locked
120Delivery &1: No support for function for CW-relevant TOs
121Change Management not supported for CW items
122Immediate confirmation for CW only possible in HU environment
123Default quantity calculated using plan conversion factor of material
124This unit or measure is not allowed as a logistics unit of measure
125CW material &1 / &2 - fill logistical and parallel quantity
126SC components are ignored as one component is a CW material
127Switch to display mode as components contain CW materials
Privacy Policy