/ISDFPS/LM_STB_APP - Nachrichtenklasse der Applikationsschicht
The following messages are stored in message class /ISDFPS/LM_STB_APP: Nachrichtenklasse der Applikationsschicht.
It is part of development package /ISDFPS/LM_STB_APP in software component IS-DFS-LM-STS. This development package consists of objects that can be grouped under "Appl. Layer of the Line Maintenance Appl. - Status Board".
It is part of development package /ISDFPS/LM_STB_APP in software component IS-DFS-LM-STS. This development package consists of objects that can be grouped under "Appl. Layer of the Line Maintenance Appl. - Status Board".
Message Nr ▲ | Message Text |
|---|---|
| 001 | You are not authorized to display the object |
| 002 | Inbound destination &1 not found; maintain background RFC settings |
| 003 | Setup of index table has exceeded the permitted time frame |
| 004 | Do not use this function module as it is obsolete |
| 200 | Equipment was changed |
| 201 | Report &1 contains inconsistent variants; adjust your variants |
| 202 | Error inserting a notification in the status board; no object reference |
| 203 | Error deleting a notification from the status board; no object reference |
| 204 | Internal error; object &1 could not be updated |
| 205 | Error while deleting measurement doc. from status board; zero obj. ref. |
| 206 | Error while inserting measurement doc. in status board; zero obj. ref. |
| 207 | Variant &1 for report &2 does not exist |
| 208 | Internal error while checking variant |
| 209 | Canceled by user |
| 210 | Variant &1 deleted |
| 211 | Variant &1 was repaired |
| 220 | No application log exists for technical object &1 |
| 221 | Internal error in method &1 of class &2 |
| 222 | Internal error in parameters of method &1 of class &2 |
| 223 | Internal error reading table &3 in method &1 of class &2 |
| 224 | Internal error - reference &3 in method &1 of class &2 is zero |
| 225 | Application log contains either errors or warnings |
| 226 | The application log is empty |
| 227 | Change in status board; application log has been updated |
| 234 | Data inconsistent: no equipment record for master equipment &1 |
| 235 | Inconsistent data; there is multiple master equipment alongside &1 |
| 300 | Revision &1 and plant &2 do not exist |
| 500 | Equipment &1 was updated |
| 501 | Functional location &1 was updated |
| 502 | Operating equipment &1 was updated |
| 503 | Notification &1 was updated |
| 504 | Order &1 was updated |
| 505 | Revision &1 for plant &2 was updated |
| 506 | Measuring point &1 and measurement document &2 were updated |
| 507 | Maintenance item &1 for maintenance plan &2 has been updated |
| 508 | Order &1 was assigned to technical object &2 |
| 509 | Notification &1 was assigned to technical object &2 |
| 510 | Measurement document &1 was assigned to technical object &2 |
| 511 | Revision &1 was assigned to technical object &2 |
| 512 | Maintenance item &1 (plan &2) has been assigned to technical object &3 |
| 514 | Assignment of order &1 to technical object &2 was removed |
| 515 | Assignment of notification &1 to technical object &2 was removed |
| 516 | Assignment of revision &1 to technical object &2 was removed |
| 517 | Assignment of meas. doc. &1 to technical object &2 was removed |
| 518 | Assignment of maintenance item &1 (&2) to technical object &3 was removed |
| 519 | Technical object &2: Change icon for order &1 was set |
| 520 | Technical object &2: Change icon for notification &1 was set |
| 521 | Technical object &2: Change icon for revision &1 was set |
| 522 | Technical object &2: Change icon for measurement document &1 was set |
| 524 | Technical object &1; change icon was set |
| 525 | Technical object &2: Change icon for order &1 was deleted |
| 526 | Technical object &2: Change icon for notification &1 was deleted |
| 527 | Technical object &2: Change icon for revision &1 was deleted |
| 528 | Technical object &2: Change icon for measurement document &1 was deleted |
| 530 | Technical object &1; change icon was deleted |
| 531 | Technical object &2: equipment &1 has been installed |
| 532 | Technical object &2: equipment &1 has been dismantled |
| 533 | Technical object &2: main measuring point &1 updated |
| 560 | Performance measurement in cl. &1 - &2: &3 sec (objects: &4) |
| 561 | Performance measurement in cl. &1 - &2: &3 sec |
| 562 | Performance settings: &1 = '&2' |
| 563 | Lock error: Lock for master equipment &1 cannot be set |
| 564 | Lock error: Lock for table &1 cannot be set |
| 565 | Technical error; inform your administrator |