/ISDFPS/LM_STB_APP - Nachrichtenklasse der Applikationsschicht

The following messages are stored in message class /ISDFPS/LM_STB_APP: Nachrichtenklasse der Applikationsschicht.
It is part of development package /ISDFPS/LM_STB_APP in software component IS-DFS-LM-STS. This development package consists of objects that can be grouped under "Appl. Layer of the Line Maintenance Appl. - Status Board".
Message Nr
Message Text
001You are not authorized to display the object
002Inbound destination &1 not found; maintain background RFC settings
003Setup of index table has exceeded the permitted time frame
004Do not use this function module as it is obsolete
200Equipment was changed
201Report &1 contains inconsistent variants; adjust your variants
202Error inserting a notification in the status board; no object reference
203Error deleting a notification from the status board; no object reference
204Internal error; object &1 could not be updated
205Error while deleting measurement doc. from status board; zero obj. ref.
206Error while inserting measurement doc. in status board; zero obj. ref.
207Variant &1 for report &2 does not exist
208Internal error while checking variant
209Canceled by user
210Variant &1 deleted
211Variant &1 was repaired
220No application log exists for technical object &1
221Internal error in method &1 of class &2
222Internal error in parameters of method &1 of class &2
223Internal error reading table &3 in method &1 of class &2
224Internal error - reference &3 in method &1 of class &2 is zero
225Application log contains either errors or warnings
226The application log is empty
227Change in status board; application log has been updated
234Data inconsistent: no equipment record for master equipment &1
235Inconsistent data; there is multiple master equipment alongside &1
300Revision &1 and plant &2 do not exist
500Equipment &1 was updated
501Functional location &1 was updated
502Operating equipment &1 was updated
503Notification &1 was updated
504Order &1 was updated
505Revision &1 for plant &2 was updated
506Measuring point &1 and measurement document &2 were updated
507Maintenance item &1 for maintenance plan &2 has been updated
508Order &1 was assigned to technical object &2
509Notification &1 was assigned to technical object &2
510Measurement document &1 was assigned to technical object &2
511Revision &1 was assigned to technical object &2
512Maintenance item &1 (plan &2) has been assigned to technical object &3
514Assignment of order &1 to technical object &2 was removed
515Assignment of notification &1 to technical object &2 was removed
516Assignment of revision &1 to technical object &2 was removed
517Assignment of meas. doc. &1 to technical object &2 was removed
518Assignment of maintenance item &1 (&2) to technical object &3 was removed
519Technical object &2: Change icon for order &1 was set
520Technical object &2: Change icon for notification &1 was set
521Technical object &2: Change icon for revision &1 was set
522Technical object &2: Change icon for measurement document &1 was set
524Technical object &1; change icon was set
525Technical object &2: Change icon for order &1 was deleted
526Technical object &2: Change icon for notification &1 was deleted
527Technical object &2: Change icon for revision &1 was deleted
528Technical object &2: Change icon for measurement document &1 was deleted
530Technical object &1; change icon was deleted
531Technical object &2: equipment &1 has been installed
532Technical object &2: equipment &1 has been dismantled
533Technical object &2: main measuring point &1 updated
560Performance measurement in cl. &1 - &2: &3 sec (objects: &4)
561Performance measurement in cl. &1 - &2: &3 sec
562Performance settings: &1 = '&2'
563Lock error: Lock for master equipment &1 cannot be set
564Lock error: Lock for table &1 cannot be set
565Technical error; inform your administrator
Privacy Policy