/PLMU/UI_RCP - Recipe UI message class
The following messages are stored in message class /PLMU/UI_RCP: Recipe UI message class.
It is part of development package /PLMU/UI_RCP in software component PLM-WUI-RCP. This development package consists of objects that can be grouped under "UI: Recipe".
It is part of development package /PLMU/UI_RCP in software component PLM-WUI-RCP. This development package consists of objects that can be grouped under "UI: Recipe".
Message Nr ▲ | Message Text |
|---|---|
| 001 | No explosion has run, therefore no log exists |
| 002 | Explosion log is outdated (created on: &1 at &2) |
| 003 | Dimension for unit of measure &1 not found |
| 004 | Units of measure for upper and lower limit must have the same dimension |
| 005 | Maximum value has a different dimension |
| 006 | Minimum value has a different dimension |
| 007 | Target value has a different dimension |
| 008 | Not possible to determine user format |
| 009 | Value is not a number according to user format |
| 010 | Technical error; contact your system administrator |
| 011 | Target value is not a number |
| 012 | Technical error; contact your system administrator |
| 013 | Minimum value is not a number |
| 014 | Maximum value is not a number |
| 015 | Navigation is not possible for a stream without assigned specification |
| 016 | Only numerical values allowed |
| 017 | Technical error; contact your system administrator |
| 018 | Simulation deactivated |
| 019 | Cannot move process element; renumber elements and try again |
| 020 | Cannot move process element to the location you specified |
| 021 | Process element &1 changed to &2 |
| 022 | You cannot drag-and-drop items here |
| 023 | Customizing settings for automatic specification creation are missing |
| 100 | *** Messages for Recipe Process |
| 101 | Select one process element for processing |
| 102 | Process element has no valid key |
| 103 | Filter results in an empty table |
| 104 | Long text could not be assigned; no process element found |
| 105 | Long text could not be assigned; no description found |
| 106 | Copy buffer is empty; the system cannot paste data |
| 107 | Expand &1 |
| 108 | Process elements renumbered |
| 109 | Description without any element ID is not possible |
| 110 | No search results found for: &1 |
| 111 | Last item reached |
| 112 | No equipment requirement assigned |
| 113 | Long text could not be assigned; no equipment requirement found |
| 114 | Equipment requirements renumbered |
| 115 | First item reached |
| 116 | Long text could not be assigned; no process parameter found |
| 117 | No process parameter assigned |
| 118 | Choose a recipe and refresh data to complete the import process |
| 119 | |
| 200 | *******Messages for Recipe Specification |
| 201 | Fill in all required fields |
| 202 | Specification &1 was created but not yet saved |
| 203 | Specification &1 was discarded |
| 300 | *******Messages for Formula |
| 301 | Formula items were renumbered |
| 400 | ***** Messages for Manual Composition ******* |
| 401 | Specification &1 with component type &2 already exists in the composition |