/SCMB/TDL_DAO - TDL: General Error im DAO
The following messages are stored in message class /SCMB/TDL_DAO: TDL: General Error im DAO.
It is part of development package /SCMB/TDL_DAO in software component SCM-BAS-TDL. This development package consists of objects that can be grouped under "TSP: Data Access Objects (DAO)".
It is part of development package /SCMB/TDL_DAO in software component SCM-BAS-TDL. This development package consists of objects that can be grouped under "TSP: Data Access Objects (DAO)".
Message Nr ▲ | Message Text |
---|---|
000 | General DAO error: &TEXT& |
001 | No TDL time series ID from /SCMB/TDL_TS table supplied |
002 | /SCMB/TDM_TSDM_TS_GET function call error |
003 | No TDL time series version ID supplied |
004 | Invalid selection time frame |
005 | /SCMB/TDM_TSDM_TS_SET function call error |
006 | Invalid time series type during metadata release |
007 | Unknown error while calling metadata |
008 | /SCMB/TSDM_TSTP_READ function call error |
009 | No technical type configured for the specified time series type |
010 | No key figures found for the semantics supplied |
011 | One or more time series data records contain no values |
012 | Time series data type not found in TSDM |
013 | Time series data type not found in TSDM |
014 | Time profile not found in TSDM |
015 | /SCA/TSDM_TSTP_DATA_READ function call erro |
016 | Error while creating period table: wrong periods supplied |
017 | Error while creating period table: unknown error |
018 | /SCMB/DM_INV_DATA_GET function call error |
019 | Error calling LIME |
020 | ODM access error |
021 | Internal error in ODM: &1 |
022 | User transfered a wrong interface reference |
023 | No table with material- and location IDs was transfered |
024 | No characteristics found for the given semantics |
025 | Error reading time series from TSDM for TSID &1 |
026 | /SCMB/TDM_TSDM_TS_SAVE function call error |
027 | Error while emptying buffer |
028 | Error during locking |
029 | Error during data release |
030 | Invalid selection criteria: &1 |
031 | No selection criteria specified for product |
032 | No selection criteria specified |
033 | No corresponding delivery plan found |
034 | No corresponding entry found |
035 | No appropriate source of supply found |
036 | Incorrect or unknown version |
037 | Missing entry for order type |
038 | No category found for semantics specified |
039 | Error while deleting time series for TSID &1 |
040 | Buffer error: |
041 | Error during buffer creation |
042 | Error saving the time series buffer for the TSDM TSTP &1 |
043 | No TZONE found during time conversion |
044 | Error reading a value from the number range |
045 | Characteristics were not transfered |
046 | Key figures were not transfered |
047 | Information for access with local time stamp was not transfered |
048 | Information for access with UTC time stamp was not transfered |
049 | No time criteria transfered |
050 | Error while writing time series for TSID &1 |
051 | Function not implemented |
052 | Too many time parameters transfered |
053 | No time parameters transfered |
054 | No time zone for the time parameters released |
055 | No data was transfered |
056 | VCP flag characteristic for the facing locations is not permitted here |
057 | Read module for ASN access not found |
058 | One or more Order GUIDs have not been supplied |
059 | One or more periods were not supplied |
060 | Current period is invalid |
061 | This function is not available |
062 | Time series contain no TPOP or VCP settings |
063 | Error reading PEGAREA: location &1 product &2 |
064 | Error reading LC orders |
065 | Error saving LC orders |
066 | Error Reading the Time Series |
067 | Error writing the time series |
068 | Error while deleting time series |
069 | Time selection mode not specified |
070 | Error reading the time series validity period: &1 in system &2 |
071 | You have not specified a logical target system |
072 | Too few selection criteria were transferred |
073 | Incorrect configuration of Transaction Data Layer (TDL) |
074 | Error reading ASNs |
075 | Periodicity &1 is not available in data source &2 for &3 |
076 | Key figure &1 is not available in the data source &2 |
077 | Periodicity &1 for variant &2 is not available in &3 |
078 | Fiscal year variant was not transferred |
079 | Error reading data for LC orders |
080 | Order document with ORDID &1 was transferred incompletely |
081 | Order ID &1 is unknown |
082 | Error while reading the location product master data |
083 | Error occurred while opening a transactional simulation |
084 | Error occurred while closing a transactional simulation |
085 | Planning area is invalid |
086 | Storage buckets profile cannot be found |
087 | Error while reading key figures for planning area &1 |
088 | Error creating a DAO object |
089 | No semantics exist for TSDM indicator &1 |
090 | No TSDM indicator exists for semantics &1 |
091 | Reference source &1 not found |
092 | Order &1 is blocked by user &2 |
093 | No InfoObject found for semantics &1 for data source &2 |
094 | InfoObject &1 not found in InfoProvider &2 |
095 | InfoProvider &1 not found |
096 | Error while writing time series for TSID &1 (key figure value too large) |
097 | STO &1 has items with start locations belonging to different plants |
098 | Error when writing PEGAREA |
099 | No valid time series data area for type &1, version &2 |