/SCWM/MIGRATION - Messages for Migration programs and tools
The following messages are stored in message class /SCWM/MIGRATION: Messages for Migration programs and tools.
It is part of development package /SCWM/MIGRATION in software component SCM-EWM-IF-ERP. This development package consists of objects that can be grouped under "ERP-WM to EWM Migration Tools".
It is part of development package /SCWM/MIGRATION in software component SCM-EWM-IF-ERP. This development package consists of objects that can be grouped under "ERP-WM to EWM Migration Tools".
Message Nr ▲ | Message Text |
---|---|
000 | Function module &1 does not exist in &2; implement SAP Note 1523108 |
001 | Enter an RFC connection |
002 | Enter an ERP warehouse number |
003 | Error opening dataset &1 |
004 | Error closing dataset &1 |
005 | No data found for table &1 in &2 for specified selection criteria |
006 | File &1 successfully downloaded |
007 | Migration started |
008 | Migration finished |
009 | Started reading data from ERP |
010 | Finished reading data from ERP |
011 | Started filling ERP data into local table |
012 | Finished filling ERP data into local table |
013 | Started writing data to file |
014 | Finished writing data to file |
015 | Download started |
016 | Download finished |
017 | Upload started |
018 | Upload finished |
019 | Started reading data from file |
020 | Finished reading data from file |
021 | Started transferring data from file into EWM table |
022 | Finished transferring data from file into EWM table |
023 | Started calling transaction &1 |
024 | Finished calling transaction &1 |
025 | File &1 does not exist |
026 | Field content of field &1 in line &2 could not be converted |
027 | &1 lines read from table &2 (destination &3) |
028 | &1 lines written to file |
029 | No records could be read from file &1 |
030 | Enter a file name |
031 | Enter an ERP plant number |
032 | Enter an EWM warehouse number |
033 | RFC destination could not be determined for logical system &1 |
034 | Separator only valid if you select the Assignment checkbox |
035 | Enter an ERP storage type number |
036 | Enter an EWM storage type number |
037 | Separator only valid if you select the Use Separator checkbox |
038 | Separator '/' is reserved for pallet storage sub bins |
039 | No search help available |
040 | Enter an ERP business system |
041 | ERP &1 warehouse &2 and EWM warehouse &3 mapping not maintained |
042 | Enter at least one option for download |
043 | Enter at least one option for upload |
044 | You are not authorized to use business system &2 in transaction &1 |
045 | No data found in file |
046 | Could not determine a logical system in the SLD for business system &1 |
047 | Table &1 cannot be read |
048 | You are not authorized to use transaction &1 |
049 | Upload/ Download to local file is not possible in Background mode. |
050 | ****** Product *********** |
051 | RFC destination &1 determined |
052 | ERP warehouse number and EWM warehouse number mapping not maintained |
053 | Error converting product master data |
054 | Error writing product master data |
055 | Invalid table name for field mapping |
056 | Start of update product master |
057 | End of update product master |
058 | &1 Product master records written from &2 |
059 | Table &1; &2 product master records ignored (missing in EWM) |
060 | &1 fixed bin assignments successfully created |
061 | Error creating &1 fixed bin assignments |
062 | Started update of fixed bin assignments |
063 | Finished update of fixed bin assignments |
064 | Global product data does not exist in EWM |
065 | No data for creation of packaging specification found |
066 | Error reading partner data for &1 |
067 | Business partner &1 does not exist |
068 | Keyfield is initial, record &1 ignored |
069 | During upload, select-options are ignored |
070 | Error converting stock data (Quant &1) |
071 | Started mapping LQUA entries without handling unit data |
072 | Finished mapping LQUA entries without handling unit data |
073 | Started mapping LQUA entries with handling unit data |
074 | Finished mapping LQUA entries with handling unit data |
075 | Mapping is not working; maintain Customizing settings |
076 | Plant &1, storage location &2, material &3 |
077 | Documentary batch indicator cannot be set in warehouse product |
078 | Material &1 cannot be found |
079 | Check product &1 in EWM |
080 | No mapping value found for storage unit type &1. |
081 | Quant &1 is a blocked stock; after migration it is no longer blocked |
082 | Quant &1 has an open transfer order |
083 | No activity found for categories 'Picking' or 'Cross-Line Stock Putaway' |
084 | At least one bin contains non-numeric sorting value; resorting for &1 |
085 | File names must not be the same |
086 | Alternative UoM could not be calculated for &1 Products(check mat.master) |
087 | No mapping values found for alternative UoM &1 |
088 | Quant &1 has an open inventory document |
089 | Quant &1 has a negative or null stock |
090 | Error creating packaging specifications |
091 | Condition type &1 for application &2 and usage &3 not found |
092 | &1 is not a valid packaging material |
093 | Packaging material &1 is not defined |
094 | Packaging Material &1 for HU &2 not found |
095 | Warehouse product &1 disposal party &2 already exists, no update |
100 | ****** Physical Inventory Completeness *********** |
101 | No inventory area found for warehouse &1 |
102 | Processing inventory area &1 |
103 | No business partner exists for ERP plant &1 |
104 | Product &1 storage bin &2 has an open inventory document |
105 | No EWM master data found for product &1 |
106 | Date &1 is invalid |
107 | Entitled &1 does not exist |
108 | Material &1 is not counted completely in the ERP warehouse |
109 | No data was written to file |
110 | For &1 SUoM-relevant products, no pack specs have been created |
111 | Existing warehouse product &1 disposal party &2 was updated |
112 | &1: Product master successfully written for &2 |
113 | Warehouse number must be unique |
114 | Duplicate entry for &1 &2 &3 &4 not processed |
115 | Lock server system error for &1 |
116 | Cannot lock product &1; product not changed |
117 | Cannot unlock product &1 |
118 | Product &1: You have no authorization to create; product not created |
119 | Business partner for warehouse &1 cannot be found |
120 | Storage bin &1 already exists; it will be overwritten |
121 | No warehouse data provided; no products uploaded |
122 | You can't make changes in warehouse &1 storage type &2. |
123 | You can't create new objects in warehouse &1 storage type &2. |
124 | You can't convert date &1 or time &2 to a timestamp |
125 | Cannot read Customizing for storage type &1 |
126 | Storage bin type &1 not found in Customizing |
127 | Storage bin &1 uploaded |
128 | Warehouse number &1 does not have a disposal party assignment |
129 | Party entitled to dispose &1 not assigned to warehouse number &2 |
130 | Missing authorization: Auth. object /SCWM/SLFU with parameters &1 &2 |
131 | Warehouse &1 is not a valid warehouse |
132 | Messages for warehouse product &1 party entitled to dispose &2: |
133 | Error in goods movement posting; no data uploaded |
134 | Cannot convert unit &1 to internal format |
135 | You can't convert date &1 to a timestamp |
136 | Decimal notation in system does not match decimal notation in CSV file |
137 | Bin already exists; date of last PI, bin mvt or bin clearing not changed |
138 | Cannot change inventory type when the bin already exists |
140 | You are not authorized to migrate storage bins |
141 | Existing bin sorting for bin &1 activity &2 was updated |
142 | Storage bin &1 could not be updated with cross-line putaway sort sequence |
143 | Bin sorting for bin &1 activity &2 uploaded |
144 | Bin sorting for bin &1 activity &2 could not be updated |
145 | You are not authorized to migrate storage bin sorting data |
146 | You are not authorized to migrate warehouse products |
147 | Storage type &1 changed to &2 (based on storage bin data) |
148 | Storage section &1 changed to &2 (based on storage bin data) |
149 | You are not authorized to modify bin sorting data in warehouse &1 |
150 | Storage bin &1: Cannot convert max. weight UoM &2 to warehouse UoM &3 |
151 | Storage bin &1: Cannot convert max. volume UoM &2 to warehouse UoM &3 |
152 | Technical error: Data couldn't be transformed into internal structures |
153 | Messages for warehouse &1 bin &2 highest-level handling unit &3: |
154 | Messages for source record: Storage bin = &1 |
155 | Aisle &1 changed to &2 (based on storage bin data) |
156 | Field �Posting Date� must match for all stock data |
158 | Message from saving the capacity data of handling unit &1: |
159 | Messages for Source Record Item: &1, &2, &3, &4 |
160 | Field �Stock Upload to WM Only� must match for all stock data |
161 | You are not authorized to perform the download for migration |
162 | Download of selected storage bin sorting data complete |
163 | No data selected for download of storage bin sorting |
164 | You are not authorized to migrate stock |
165 | Download canceled by user |
166 | Download failed of selected storage bin sorting data |
167 | Row ID must be unique (row ID &1) |
168 | Handling unit &1 and highest-level handling unit &2 must be the same |
169 | No changes to existing bin sorting for bin &1 activity &2 |
170 | You are not authorized to migrate fixed bin assignments |
171 | Fixed bin assignment for &1, &2, &3, &4 uploaded |
173 | System error during creation of handling unit |
174 | System error during creation of sub bins |
175 | System error when saving the created handling units |
176 | Item for serial number &1 cannot be determined for row &2 |
180 | Storage bin type &1 (flexible bin) is not supported for this transaction |
181 | Flexible bin &1/&2 is not supported for this transaction |
182 | Creation of handling unit &1 failed |
183 | Cannot unlock storage bin &1 |
184 | Duplicate row IDs. No stock items were uploaded. |
185 | Migration into an embedded warehouse is not supported |
186 | Bin access type &1 not maintained for warehouse &2. |
200 | ****** Settings *********** |
201 | Log object &2 for user &3 is defined in warehouse &1 |
202 | PPF log deactivated for warehouse &1 and user &2 |
203 | PPF log deactivated for warehouse &1 |
204 | User &1 with data entry type &2 already exists |
205 | Resource &2 already exists in warehouse &1 |
206 | Resource group &2 already exists in warehouse &1 |
207 | Resource group &2 has queue type sequence &3 in warehouse &1 |
208 | Resource group &2 has queue sequence &3 in warehouse &1 |
209 | Default values are not defined for warehouse &1 |
210 | REC for stor. group &3, stor. type &2 in warehouse &1 does not exist |
211 | Process type &2 in warehouse &1 does not exist |
212 | Priority parameter &3 for mode &2 in warehouse &1 already exists |
213 | Bin access type &3 for resource type &2 in warehouse &1 does not exist |
214 | HU group &3 for resource type &2 in warehouse &1 does not exist |
215 | Work center &2 does not exist in warehouse &1 |
216 | Printer control &3 for work center &2 in warehouse &1 already exists |
217 | No work station determination for route &1, acty. area &2, cons. group &3 |
218 | No work station determination for HU type group &2 in storage type &1 |
219 | Production supply area &2 in warehouse &1 already exists |
220 | Assignment &3 for PSA &2 in warehouse &1 does not exist |
221 | Resource &2 does not exist in warehouse &1 |
222 | Programmable logic controller &2 does not exist in warehouse &1 |
223 | Communication point &3 for PLC &2 does not exist in warehouse &1 |
224 | Communication channel &3 for PLC &2 does not exist in warehouse &1 |
225 | Object &3/&4 assigned to PLC &2 in warehouse &1 |
226 | Aisle &3 / level &4 already exists for resource &2, storage type &1 |
227 | RFC destination &1 does not exist |
228 | Function module &1 does not exist |
229 | User &1 already assigned to tolerance group for recount/clearing in WH &2 |
230 | User &1 already assigned to tolerance group for diff. analyzer in WH &2 |
231 | Door &1 in warehouse &2 does not exist |
232 | Route &1 in warehouse &2 already exists |
233 | /SCWM/STADET_IN: WPT &1, HU type &2, and MTr &3 already exist in WH &4 |
234 | Entry in /SCWM/STADET_OUT already exists for warehouse &1 |
235 | Direction &1 (Access Sequence Number &2) in warehouse &3 already exists |
236 | Combination of Route &1, MTr &2, PMat &3, and StAreaGrp &4 already exists |
237 | Migration of MO "&1" is not relevant for current source system |
238 | Supply Chain Unit &1 does not exist |
239 | Packaging Specification ID &1 does not exist |
240 | Overlapping validity periods for condition type &1 application &2 WhNo &3 |
241 | Warehouse independent entry already exists for condition type &1 appl &2 |
242 | Cannot define database name of condition table with ID &1 |
243 | Database table &1 does not exist or is inactive |
244 | Data validation started for application &1 |
245 | Database table &1 does not have a valid structure |
246 | Tech issue: No data about table structure for source table &1 |
247 | Workstation &2 is already assigned for VAS in WH &1 (/SCWM/V_VASBDET) |
248 | Warehouse costs for starting date &2 in warehouse &1 already exist |
250 | Wave template &1 already exists in warehouse &2 |
251 | Wave template &1 option &2 already exists in warehouse &3 |
252 | Determination Profile for &1 already exists (/SCWM/V_CAPPD) |
253 | Warehouse &1 and disposal party &2 already assigned to customer ID |
254 | Exception code profile &1 is already assigned to user &2 |
255 | BinDet for ProdGrType/ProdGr &2 for DocType/ItmType &1 with Seq &3 exists |
256 | Package assignment for &1 already exists |
257 | Snapshot settings &2 for warehouse &1 already exist |
258 | Package Building Profile &1 doesn't exist |
260 | RFC destination already exists for warehouse &1 |
261 | RFID postings for partner &1 already exist in warehouse &2 |
262 | RFID is inactive in source system, so no EPC data will be migrated |
263 | RFID is inactive in target system, so no EPC data will be migrated |
264 | Empty value is not allowed for warehouse number |
265 | Cross-warehouse data: warehouse number should be empty |
300 | ****** Route *********** |
301 | Transportation zone &1 already exists |
302 | Location &1 has the wrong location type (&2 is needed) |
303 | Route &1 does not exist |
304 | Leg &1 not found |
305 | Stop &2 in leg &1 not found |
306 | Transportation zone &1 does not exist |
307 | Leg &1 already exists |
308 | Transportation zone ID is empty |
309 | Table with transportation zones hierarchy can't be empty |
310 | Route ID is empty |
311 | Leg &1 does not exist |
312 | Leg &1 does not belong to a route |
350 | ****** Quality Inspection *********** |
351 | Active version of Inspection Object Type &1 is not found |
352 | Inspection Object Type is not specified |
353 | The rule with key &1 already exists and cannot be changed |