/SCWM/UI_PI - Messages for User Interface: Physical Inventory Processing

The following messages are stored in message class /SCWM/UI_PI: Messages for User Interface: Physical Inventory Processing.
It is part of development package /SCWM/CORE_UI_DE in software component SCM-EWM. This development package consists of objects that can be grouped under "Core User Interface".
Message Nr
Message Text
001Enter warehouse number 'Settings -> Default Values'
002You are not permitted to set/reset the blocking indicator for method &1
003You are not permitted to fix/reset book inventory balance for method &1
004No objects selected
005Enter a physical inventory procedure under 'Settings -> Default Values'
006Enter a planned count date under 'Advanced Search'
007Phys. inv. doc. &1 &2, item &3 created as 'active'; deactivation canceled
008Enter a physical inventory year under 'Settings -> Default Values'
009You cannot search for product data for location-specific method &1
010Physical inventory document &1 &2 is already locked by another user
011Function '&1' not permitted for phys. inv. doc. &2 &3 with status '&4'
012Function '&1' not permitted. Data has already been changed
013New line only permitted for functions 'Count' or 'Change Count'
014Line deletion only permitted for function 'Count' or 'Change Count'
015Line copying only possible when you enter count quantities
016Serial number profile for &1 does not allow you to enter serial numbers
017Enter either a physical inventory document or a warehouse order
018Item &1: PI reason is not filled
019Item &1: PI priority is not filled
020Internal error; no save possible
021Error: &1 program: &2/&3 line: &4
022PI count item &1: exception code &2 not assigned to internal process code
023HU &1 is not empty; no save possible
024HU &1 does not have a status; no save possible
025Product &1 does not have a correct count entry; no save possible
026Not all quants for product &1 were counted; no save possible
027Count quantity will be adjusted to number of serial numbers created
028Item category HU not allowed in storage bin check
029PI count item &1: exception code &2 cannot be used
030Exception code &1 in PI count item inserted cannot be used
031Exception code &1 in count item inserted not assigned to int. proc. code
032Item &1, line &2, product &3: serial number must be specified
033Item &1: products already counted are lost through exception code &2
034Serial number proposal not possible for serial number profile &1
035Serial number proposal not allowed in physical inventory area &1
036Physical inventory doc. &1 item &2; count date must not be in the future
037Phys. inventory doc. &1 item &2; count time must not be in the future
038Physical inventory document &1 item &2; no counting data entered
039PID &1 &2 itm &3 cannot be used; delete the document and create a new one
040Enter different units of measure for CW product
041'Storage bin empty' and exception &1 cannot be set simultaneously
042Selectable item.: Labor Mgmt not active for all acty areas; proc. cancld.
043&1 is the valuation unit of measure; enter the correct data
044&1 is a logistical unit of measure; enter the correct data
045Physical inventory document &1 item &2; enter a valid processor
046Only select items of one warehouse order
047No new items can be created for main bin &1
048Enter either a PSA or a bin
049You have set "Bin Empty"; system ignores other count entries
050You have set "HU Complete"; system ignores dependent count entries
051You have set "HU Empty"; system ignores dependent count entries
052You have set "HU Missing"; system ignores dependent count entries
053HU &1 is currently on bin &2
054Item &1, count item &2: Date of Goods Receipt must not be in the future
055Serial number &1 is assigned to the party entitled to dispose &2
056You must enter a count reference for PI Document &1 Item &2.
057The count reference is not valid.
Privacy Policy