OIU_OIISLVCKO_D - Draft table for entity I_PRASILOCALIBRNSETHDR

Draft table for entity I_PRASILOCALIBRNSETHDR information is stored in SAP table OIU_OIISLVCKO_D.
It is part of development package OIU_TANK in software component IS-OIL-PRA-PRD. This development package consists of objects that can be grouped under "PRA Tank strapping".

Fields for table OIU_OIISLVCKO_D

Field Name
Description
Is Key
Data Element
Data Type
Length
Check Table
MANDTClientXMANDTCLNT6
TANKSTRAPPINGHDRUUID16 Byte UUID in 16 Bytes (Raw Format)XSYSUUID_X16RAW16
TANKSTORAGEOBJUUID16 Byte UUID in 16 Bytes (Raw Format)SYSUUID_X16RAW16
TANKSTRAPPINGEFFCTVFRMDATEEffective from dateOIU_EFF_FROM_DTDATS16
TANKSTRAPPINGEFFCTVTODATEEffective To DateOIU_EFF_TO_DTDATS16
TANKSTRAPPINGUOMNMBROFDECIMALSSOC: No. of decimal places in linear value of LVCC setOIU_OII_NRDECNUMC2
FLOWRATEUNITOFMEASUREUoM - flow rate (Oil BDRP)OIU_OII_FRTUNUNIT6
OILTANKMAXIMUMINFLOWQTYMaximum inflowOIU_OII_MAXINQUAN7
OILTANKMAXIMUMOUTFLOWQTYMaximum outflowOIU_OII_MAXOUTQUAN7
OILTANKMAXIMUMCONTAMINANTQTYMaximum contaminant quantity (UoM VOL)OIU_OII_WASKZQUAN7
OILTANKMAXIMUMCONTAMINANTPCTMaximum contaminant qty. (as % of total capacity)OIU_OII_WASPCDEC3
THERMALEXPANSIONISSELECTEDSilo Management: Thermal Tank Expansion CorrectionOIU_OII_EXPACORRCHAR2
FLOATINGROOFCRRTNISSELECTEDSilo management: floating roof correctionOIU_OII_ROOFCORRCHAR2
WATERCORRECTIONISSELECTEDSilo management: water correctionOIU_OII_WATRCORRCHAR2
DIPPINGMETHODINNAGEULLAGEDipping method (innage, ullage)OIU_OII_UL_IN_INDCHAR2
TANKTHRMLINSULATIONISSELECTEDTank has thermally insulated shellOIU_OII_ISO_SHELLCHAR2
MAXIMUMHEIGHTMaximum permissible dip (UoM LEN)OIU_OII_MAXDPQUAN7
MINIMUMHEIGHTMinimum permissible (feasible) dip (Uom Len)OIU_OII_MINDPQUAN7
UNPUMPABLEQUANTITYUnpumpable quantity (UoM VOL)OIU_OII_UNPKZQUAN7
UNPUMPABLEQUANTITYINPCTUnpumpable quantity expressed as perc. of total capacityOIU_OII_UNPPCDEC3
FLOATINGROOFWEIGHTFloating roof weightOIU_OII_FLMASQUAN7
THERMALEXPANSIONCOEFFICIENTVALSilo Shell: Linear Thermal Expansion CoefficientOIU_OII_EXPCOEFFDEC8
TANKDIPTOTALHEIGHTHeight of liquid in tank, when calibratedOIU_OII_CALFILHGTQUAN7
OILTANKCALIBRATIONTEMPERATURECalibration temperatureOIU_OII_CALTEMPQUAN7
OILTANKCALIBRATIONLQDDENSCalibration liquid densityOIU_OII_CALDENSQUAN7
OILTANKCALIBRATORNAMECalibrator nameOIU_OII_CALNAMECHAR60
OILTANKCALIBRATIONDATEDateDATUMDATS16
MINIMUMFLOATINGROOFHEIGHTMinimum height for floating roof correction to be appliedOIU_OII_MIN_FLTROOFQUAN7
TANKCAPACITYSO capacity (UoM VOL)OIU_OII_KAPAZQUAN7
NUMBEROFINCHESINCREMENTSIncrement of inches for US Foot logic (FT/INCH/PARTS)OIU_OII_INCREMENTCHAR4
MATERIALVOLUMEUOMVolume UoM (Oil BDRP)OIU_OII_VOLUNUNIT6
MASSUOMTANKUoM - mass (Oil BDRP)OIU_OII_MASUNUNIT6
TANKDIPTOTALHEIGHTUOMLength UoM (Oil BDRP)OIU_OII_LENUNUNIT6
VOLUMEPERHEIGHTUNITOFMEASUREUoM - flow rate (Oil BDRP)OIU_OII_FRTUNUNIT6
DISPLAYTIMEUNITUoM - time (Oil BDRP)OIU_OII_TIMUNUNIT6
UNITOFMEASURETEMPERATUREUNITUoM - temperature (Oil BDRP)OIU_OII_TMPUNUNIT6
UNITFORDENSITYDensity UoM (Oil product/Silo)OIU_OII_DNSUNUNIT6
DENSITYTYPEDensity TypeOIU_OIB_DNTYPCHAR2
PRALOCLLASTCHGDATDATETIMEPRA: UTC Timestamp for RAP:Long Form (YYYYMMDDhhmmssmmmuuun)OIU_RAP_TIMESTAMPDEC11
.INCLUDE%ADMINSYCH_BDL_DRAFT_ADMIN_INC0
DRAFTENTITYCREATIONDATETIMEDraft Created AtSYCH_BDL_DRAFT_CREATED_ATDEC11
DRAFTENTITYLASTCHANGEDATETIMEDraft Last Changed AtSYCH_BDL_DRAFT_LAST_CHANGED_ATDEC11
DRAFTADMINISTRATIVEDATAUUIDDraft Administration UUIDSYCH_BDL_DRAFT_ADMIN_UUIDRAW16
DRAFTENTITYOPERATIONCODEDraft - Operation CodeSYCH_BDL_DRAFT_OPERATION_CODECHAR2
HASACTIVEENTITYDraft Flag "Has Active Instance"SYCH_BDL_DRAFT_HASACTIVECHAR2
DRAFTFIELDCHANGESDraft Field Changes as BLOBSYCH_BDL_DRAFT_FIELD_CHANGESRSTR8