CCIHT_MJIMPORT - EHS: Pooled Table for Imported Measurements

EHS: Pooled Table for Imported Measurements information is stored in SAP table CCIHT_MJIMPORT.
It is part of development package CBIH in software component EHS. This development package consists of objects that can be grouped under "EH&S: Industrial Hygiene and Safety".

Fields for table CCIHT_MJIMPORT

Field Name
Description
Is Key
Data Element
Data Type
Length
Check Table
.INCLUDEXRCGUKEY0
MANDTClientXMANDTCLNT6T000
RECNSequential Number of Data RecordXESERECNNUMC40
ACTNSequential Number of the Change StateXESEACTNNUMC40
.INCLUDERCGUADM0
VALFRValid-From DateESEVALFRDATS16
VALTOValid-To DateESEVALTODATS16
AENNRChange NumberESEAENNRCHAR24AENR
DELFLGDeletion IndicatorESEDELFLGCHAR2
PARKFLGData Record Is InactiveESEPARKFLGCHAR2
CRDATCreated OnESECRDATDATS16
CRNAMCreated ByESECRNAMCHAR24
UPDDATLast Changed OnESEUPDDATDATS16
UPDNAMLast Changed ByESEUPDNAMCHAR24
SRSIDSource of DataESESRSIDCHAR20TCG56
OWNIDData ProviderESEVENDRIDCHAR20*
RECNROOTSequential Number of Data RecordESERECNNUMC40
.INCLUDECCIHS_MJ0
OBJNRObject numberJ_OBJNRCHAR44*
MJIDMeasurement NumberCCIHE_MJIDCHAR60
MJCATSampling TypeCCIHE_MJCATCHAR6CCIHC_MJCAT
MJSTATStatusEHSBE_STATUSCHAR10
EPTYPEAgent TypeCCIHE_EPTYPECHAR20*
EPIDAgentCCIHE_EPIDCHAR40
RECNTMPWAReference to Assigned Work AreaCCIHE_RECNTMPWANUMC40
MJVALFRStart of Validity of MeasurementCCIHE_MJVALFRDATS16
MJVALTOEnd of Validity of MeasurementCCIHE_MJVALTODATS16
MSRBGNDATEDate of Start of MeasurementCCIHE_MSRBGNDATEDATS16
MSRBGNTIMETime of Start of MeasurementCCIHE_MSRBGNTIMETIMS12
MSRENDDATEDate of End of MeasurementCCIHE_MSRENDDATEDATS16
MSRENDTIMETime of End of MeasurementCCIHE_MSRENDTIMETIMS12
MDURATIONActual Duration of MeasurementCCIHE_MDURATIONTIMS12
MPLDURATIONPlanned Measurement DurationCCIHE_MPLDURATIONTIMS12
MEXCHANGEPerform ConversionCCIHE_MEXCHANGECHAR2
MSOURCEIDSampling LocationCCIHE_MSOURCEIDCHAR6CCIHC_MSOURCE
MSOURCENOTEDescription for Sampling LocationCCIHE_MSOURCENOTECHAR510
FIXLOCFLGFixed-Location MeasurementCCIHE_FIXLOCFLGCHAR2
MPERIODRepetition of Measurement in MonthsCCIHE_MPERIODNUMC4
FLOWFlow Quantity of Measuring DeviceCCIHE_FLOWDEC3
FLOWUNITFlow UnitCCIHE_FLOWUNITUNIT6*
DVNRNumber of the Measuring DeviceCCIHE_DVNRCHAR40
MDEVTYPEMeasuring Device TypeCCIHE_DVTYPECHAR6CCIHC_DVTYPE
METHODMeasurement MethodCCIHE_METHODCHAR10CCIHC_METHOD
MPERSONTest PersonCCIHE_MJPERSONCHAR20
MPERSONGRPPerson GroupCCIHE_PERSGRPCHAR2
MPERSONNAMEFull Name of PersonCCIHE_FULLNAMECHAR160
MJNOTE1Remarks on MeasurementCCIHE_MJNOTECHAR144
MJNOTEFLG1Long TextESELTXTFLGCHAR2
MJNOTE2Remarks on MeasurementCCIHE_MJNOTECHAR144
MJNOTEFLG2Long TextESELTXTFLGCHAR2
RESPIRATORRespiratory ProtectionCCIHE_RESPIRATORCHAR2
SAMPLENRContainer or FilterCCIHE_SAMPLENRCHAR60
MJCOSTACCost Center for Measurement ProjectCCIHE_MPCOSTACCHAR20*
MJCTRAREAControlling AreaCCIHE_MPCTRAREACHAR8TKA01
RECNTMJReference to Partial MeasurementCCIHE_RECNTREFMJNUMC40
LIMEXCEEDFLGReference Value ExceededCCIHE_LIMEXCEEDFLGCHAR2
STMFLGShort-Term SampleCCIHE_STMFLGCHAR2
METCOASTSCost of AnalysisCCIHE_MCOSTSCURR6
METCUKYCurrency Key for CostsCCIHE_METCUKYCUKY10*
VOLUMETotal Volume in LitersCCIHE_VOLUMEFLTP8
VOLDECIMALSDecimal Places for a Measured Physical Variable ValueCCIHE_HQVALDECIMALSINT44
MJCOCODECompany CodeCCIHE_MPCOCODECHAR8*
FLGEXPLOCKObject Is in ExportCCIHE_FLGEXPLCKCHAR2
OPCONDOperation Status of Work Area/PatternCCIHE_OPCONDCHAR6CCIHC_OC01
IMP_DATEDate of ImportCCIHE_IMPDATEDATS16
IMP_TIMETime of ImportCCIHE_IMPTIMETIMS12
UNAMEUser NameSYUNAMECHAR24
ERRORMODEIndicator: Error or warning in an API functionESEERRMODECHAR2
ERRORINFOCount parametersNUMC4NUMC8
ERRORCLASSMessage ClassSYMSGIDCHAR40*
ERRORPARAM30 CharactersCHAR30CHAR60
Privacy Policy